Abstract

Purpose

Minimally invasive interventions offer benefits for patients, while also entailing drawbacks for surgeons, such as the loss of depth perception. Thus estimating distances, which is of particular importance in gastric bypasses, becomes difficult. In this paper, we propose an approach based on stereo endoscopy that segments organs on-the-fly and measures along their surface during a minimally invasive interventions. Here, the application of determining the length of bowel segments during a laparoscopic bariatric gastric bypass is the main focus, but the proposed method can easily be used for other types of measurements, e.g., the size of a hernia.

Methods

As input, image pairs from a calibrated stereo endoscope are used. Our proposed method is then divided into three steps: First, we located structures of interest, such as organs and instruments, via random forest segmentation. Two modes of instrument detection are used. The first mode is based on an automatic segmentation, and the second mode uses input from the user. These regions are then reconstructed, and the distance along the surface of the reconstruction is measured. For measurement, we propose three methods. The first one is based on the direct distance of the instruments, while the second one finds the shortest path along a surface. The third method smooths the shortest path with a spline interpolation. Our measuring system is currently one shot, meaning a signal to begin a measurement is required.

Results

To evaluate our approach, data sets from multiple users were recorded during minimally invasive bowel measurements performed on phantoms and pigs. On the phantom data sets, the overall average error was \(12.5\,\pm \,9.4\,\%\) on shorter pieces of bowel (\(\sim \)5 cm) and \(7.8\,\pm \,8.7\,\%\) on longer pieces (\(\sim \)10 cm). On the porcine data sets, the average error was \(17.7\,\pm \,13.3\,\%\).

Conclusion

We present and evaluate a novel approach that makes measuring on-the-fly during minimally invasive surgery possible. Furthermore, we compare different methods for determining the length of bowel segments. The only requirement for our approach is a calibrated stereo endoscope, thereby keeping the impact on the surgical workflow to a minimum.
Literature
1.
go back to reference Schauer PR, Ikramuddin S, Hamad G, Eid GM, Mattar S, Cottam D, Ramanathan R, Gourash W (2003) Laparoscopic gastric bypass surgery: current technique. J Laparoendosc Adv Surg Tech 13(4):229–239CrossRef Schauer PR, Ikramuddin S, Hamad G, Eid GM, Mattar S, Cottam D, Ramanathan R, Gourash W (2003) Laparoscopic gastric bypass surgery: current technique. J Laparoendosc Adv Surg Tech 13(4):229–239CrossRef
2.
go back to reference Maier-Hein L, Mountney P, Bartoli A, Elhawary H, Elson D, Groch A, Kolb A, Rodrigues M, Sorger J, Speidel S, Stoyanov D (2013) Optical techniques for 3d surface reconstruction in computer-assisted laparoscopic surgery. Med Image Anal 17(8):974–996CrossRefPubMed Maier-Hein L, Mountney P, Bartoli A, Elhawary H, Elson D, Groch A, Kolb A, Rodrigues M, Sorger J, Speidel S, Stoyanov D (2013) Optical techniques for 3d surface reconstruction in computer-assisted laparoscopic surgery. Med Image Anal 17(8):974–996CrossRefPubMed
3.
go back to reference Field M, Clarke D, Strup S, Seales WB (2009) Stereo endoscopy as a 3-d measurement tool. In: Engineering in medicine and biology society, 2009. EMBC 2009. Annual international conference of the IEEE, pp 5748–5751 Field M, Clarke D, Strup S, Seales WB (2009) Stereo endoscopy as a 3-d measurement tool. In: Engineering in medicine and biology society, 2009. EMBC 2009. Annual international conference of the IEEE, pp 5748–5751
4.
go back to reference Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330–1334CrossRef Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330–1334CrossRef
5.
go back to reference Bradski G (2000) The opencv library. Dr. Dobb’s J Softw Tools 25:120–126 Bradski G (2000) The opencv library. Dr. Dobb’s J Softw Tools 25:120–126
7.
go back to reference Röhl S, Bodenstedt S, Suwelack S, Kenngott H, Müller-Stich BP, Dillmann R, Speidel S (2012) Dense gpu-enhanced surface reconstruction from stereo endoscopic images for intraoperative registration. Med Phys 39:1632CrossRefPubMed Röhl S, Bodenstedt S, Suwelack S, Kenngott H, Müller-Stich BP, Dillmann R, Speidel S (2012) Dense gpu-enhanced surface reconstruction from stereo endoscopic images for intraoperative registration. Med Phys 39:1632CrossRefPubMed
8.
go back to reference Maier-Hein L, Groch A, Bartoli A, Bodenstedt S, Boissonnat G, Chang PL, Clancy NT, Elson DS, Haase S, Heim E, Hornegger J, Jannin P, Kenngott H, Kilgus T, Müller-Stich B, OladokunD Röhl S, Dos Santos TR, Schlemmer HP, Seitel A, Speidel S, Wagner M, Stoyanov D (2014) Comparative validation of single-shot optical techniques for laparoscopic 3-D surface reconstruction. IEEE Trans Med Imaging 33(10):1913–1930. doi:10.1109/TMI.2014.2325607 CrossRefPubMed Maier-Hein L, Groch A, Bartoli A, Bodenstedt S, Boissonnat G, Chang PL, Clancy NT, Elson DS, Haase S, Heim E, Hornegger J, Jannin P, Kenngott H, Kilgus T, Müller-Stich B, OladokunD Röhl S, Dos Santos TR, Schlemmer HP, Seitel A, Speidel S, Wagner M, Stoyanov D (2014) Comparative validation of single-shot optical techniques for laparoscopic 3-D surface reconstruction. IEEE Trans Med Imaging 33(10):1913–1930. doi:10.​1109/​TMI.​2014.​2325607 CrossRefPubMed
9.
go back to reference Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3d surface construction algorithm. ACM Siggraph Comput Graph 21:163–169 ACMCrossRef Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3d surface construction algorithm. ACM Siggraph Comput Graph 21:163–169 ACMCrossRef
10.
go back to reference Surazhsky V, Surazhsky T, Kirsanov D, Gortler SJ, Hoppe H (2005) Fast exact and approximate geodesics on meshes. ACM TOG 24:553–560 ACM Surazhsky V, Surazhsky T, Kirsanov D, Gortler SJ, Hoppe H (2005) Fast exact and approximate geodesics on meshes. ACM TOG 24:553–560 ACM
11.
go back to reference Lipman Y, Chen X, Daubechies I, Funkhouser T (2010) Symmetry factored embedding and distance. ACM TOG 29:103 ACM Lipman Y, Chen X, Daubechies I, Funkhouser T (2010) Symmetry factored embedding and distance. ACM TOG 29:103 ACM
12.
go back to reference Dijkstra EW (1959) A note on two problems in connexion with graphs. Numer Math 1(1):269–271CrossRef Dijkstra EW (1959) A note on two problems in connexion with graphs. Numer Math 1(1):269–271CrossRef
Metadata
Title
Image-based laparoscopic bowel measurement
Authors
Sebastian Bodenstedt
Martin Wagner
Benjamin Mayer
Katherine Stemmer
Hannes Kenngott
Beat Müller-Stich
Rüdiger Dillmann
Stefanie Speidel
Publication date
01-03-2016
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 3/2016
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1291-1

Other articles of this Issue 3/2016

International Journal of Computer Assisted Radiology and Surgery 3/2016 Go to the issue