Abstract

Purpose

One of the most challenging tasks in laparoscopic gynecological surgeries is suturing. Knotless barbed sutures are intended to enable faster suturing and hemostasis. We carried out a meta-analysis to compare the efficacy and safety of V-Loc barbed sutures (VBS) with conventional sutures (CS) in gynecological surgeries.

Methods

We systematically searched PubMed and EMBASE for studies published between 2010 and September 2021 comparing VBS to CS for OB/GYN procedures. All comparative studies were included. Primary analysis and subgroup analyses for the different surgery and suturing types were performed. Primary outcomes were operation time and suture time; secondary outcomes included post-operative complications, surgical site infections, estimated blood loss, length of stay, granulation tissue formation, and surgical difficulty. Results were calculated as weighted mean difference (WMD) or risk ratio (RR) and 95% confidence intervals (CI) with a random effects model, and a sensitivity analysis for study quality, study size, and outlier results was performed. PROSPERO registration: CRD42022363187.

Results

In total, 25 studies involving 4452 women undergoing hysterectomy, myomectomy, or excision of endometrioma. VBS were associated with a reduction in operation time (WMD – 17.08 min; 95% CI – 21.57, – 12.59), suture time (WMD – 5.39 min; 95% CI – 7.06, – 3.71), surgical site infection (RR 0.26; 95% CI 0.09, 0.78), estimated blood loss (WMD – 44.91 ml; 95% CI – 66.01, – 23.81), granulation tissue formation (RR 0.48; 95% CI 0.25, 0.89), and surgical difficulty (WMD – 1.98 VAS score; 95% CI – 2.83, – 1.13). No difference between VBS and CS was found regarding total postoperative complications or length of stay. Many of the outcomes showed high heterogeneity, likely due to the inclusion of different surgery types and comparators. Most results were shown to be robust in the sensitivity analysis except for the reduction in granulation tissue formation.

Conclusion

This meta-analysis indicates that V-Loc barbed sutures are safe and effective in gynecological surgeries as they reduce operation time, suture time, blood loss, infections, and surgical difficulty without increasing post-operative complications or length of stay compared to conventional sutures.
Appendix
Available only for authorised users
Literature
6.
go back to reference Greenberg JA, Goldman RH (2013) Barbed suture: a review of the technology and clinical uses in obstetrics and gynecology. Rev Obstet Gynecol 6(3–4):107–115PubMedPubMedCentral Greenberg JA, Goldman RH (2013) Barbed suture: a review of the technology and clinical uses in obstetrics and gynecology. Rev Obstet Gynecol 6(3–4):107–115PubMedPubMedCentral
7.
go back to reference van Rijssel EJ, Brand R, Admiraal C, Smit I, Trimbos JB (1989) Tissue reaction and surgical knots: the effect of suture size, knot configuration, and knot volume. Obstet Gynecol 74(1):64–68PubMed van Rijssel EJ, Brand R, Admiraal C, Smit I, Trimbos JB (1989) Tissue reaction and surgical knots: the effect of suture size, knot configuration, and knot volume. Obstet Gynecol 74(1):64–68PubMed
21.
go back to reference Gingras K, Zaruby J, Maul D (2012) Comparison of V-Loc™ 180 wound closure device and Quill™ PDO knotless tissue-closure device for intradermal closure in a porcine in vivo model: evaluation of biomechanical wound strength. J Biomed Mater Res Part B, Appl Biomater 100(4):1053–1058. https://doi.org/10.1002/jbm.b.32670CrossRef Gingras K, Zaruby J, Maul D (2012) Comparison of V-Loc™ 180 wound closure device and Quill™ PDO knotless tissue-closure device for intradermal closure in a porcine in vivo model: evaluation of biomechanical wound strength. J Biomed Mater Res Part B, Appl Biomater 100(4):1053–1058. https://​doi.​org/​10.​1002/​jbm.​b.​32670CrossRef
30.
go back to reference Morgan-Ortiz F, Contreras-Soto JO, Soto-Pineda JM, Zepeda MAL, Peraza-Garay FJ (2013) Comparison between unidirectional barbed and polyglactin 910 suture in vaginal cuff closure in patients undergoing total laparoscopic hysterectomy. Surg Technol Int 23:143–148PubMed Morgan-Ortiz F, Contreras-Soto JO, Soto-Pineda JM, Zepeda MAL, Peraza-Garay FJ (2013) Comparison between unidirectional barbed and polyglactin 910 suture in vaginal cuff closure in patients undergoing total laparoscopic hysterectomy. Surg Technol Int 23:143–148PubMed
Metadata
Title
Efficacy and safety of V-Loc™ barbed sutures versus conventional suture techniques in gynecological surgery: a systematic review and meta-analysis
Authors
Juliane Hafermann
Ubong Silas
Rhodri Saunders
Publication date
21-12-2023
Publisher
Springer Berlin Heidelberg
Published in
Archives of Gynecology and Obstetrics / Issue 4/2024
Print ISSN: 0932-0067
Electronic ISSN: 1432-0711
DOI
https://doi.org/10.1007/s00404-023-07291-3

Other articles of this Issue 4/2024

Archives of Gynecology and Obstetrics 4/2024 Go to the issue