Skip to main content
Top
Published in: International Orthopaedics 2/2007

01-04-2007 | Original Paper

Histoacryl glue in meniscal repairs (a biomechanical study)

Authors: Irfan Ayan, Mehmet Colak, Ulku Comelekoglu, Abtullah Milcan, Oya Ogenler, Volkan Oztuna, Fehmi Kuyurtar

Published in: International Orthopaedics | Issue 2/2007

Login to get access

Abstract

The purpose of this study was to investigate the biomechanical efficacy of Histoacryl (cyanoacrylate, N-asetil 2 butyl sistein) in meniscal tear repair. In our study, the primary stability of three different repair techniques in delaying the formation of a gap of 2 mm was investigated. A meniscal tear was repaired with two vertical sutures and Histoacryl in the first group; it was repaired only with Histoacryl in the second group, and with only two vertical sutures in the third group. Menisci were then placed in a tensile loading machine, and the primary stability of the repair zones was measured until a displacement of 2 mm occurred. Biomechanical force was significantly (P<0.05) high (112.0±17.20 N) in all groups when vertical suture and Histoacryl glue were used together during displacements of 0.5, 1.0, 1.5 and 2.0 mm. We believe that Histoacryl is superior to vertical sutures regarding gap delaying. It potentiates the effect of vertical suture strength, permits early motion and thus merits an in vivo study.
Literature
1.
go back to reference Ahn DK, Sims CD, Randolph MA et al (1997) Craniofacial skeletal fixation using biodegradable plates and cyanoacrylate glue. Plast Reconstr Surg 99(6):1508–1515PubMedCrossRef Ahn DK, Sims CD, Randolph MA et al (1997) Craniofacial skeletal fixation using biodegradable plates and cyanoacrylate glue. Plast Reconstr Surg 99(6):1508–1515PubMedCrossRef
2.
go back to reference Ahn JH, Wang JH, Yoo JC (2004) Arthroscopic all-inside suture repair of medial meniscus lesion in anterior cruciate ligament deficient knees: results of second-look arthroscopies in 39 cases. Arthroscopy 20(9):936–945PubMed Ahn JH, Wang JH, Yoo JC (2004) Arthroscopic all-inside suture repair of medial meniscus lesion in anterior cruciate ligament deficient knees: results of second-look arthroscopies in 39 cases. Arthroscopy 20(9):936–945PubMed
3.
go back to reference Amarante MT, Constantinescu MA, O’Connor D, Yaremchuk MJ (1995) Cyanoacrylate fixation of the craniofacial skeleton: an experimental study. Plast Reconstr Surg 95(4):639–646PubMedCrossRef Amarante MT, Constantinescu MA, O’Connor D, Yaremchuk MJ (1995) Cyanoacrylate fixation of the craniofacial skeleton: an experimental study. Plast Reconstr Surg 95(4):639–646PubMedCrossRef
4.
go back to reference Asik M, Sen C, Taser OF, Sozen YV, Alturfan AK (2002) Arthroscopic meniscal repair with the use of conventional suturing materials. Acta Orthop Traumatol Turc 36(3):228–235. TurkishPubMed Asik M, Sen C, Taser OF, Sozen YV, Alturfan AK (2002) Arthroscopic meniscal repair with the use of conventional suturing materials. Acta Orthop Traumatol Turc 36(3):228–235. TurkishPubMed
5.
go back to reference Asik M, Sener N, Akpinar S, Durmaz H, Goksan A (1997) Strength of different meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 5(2):80–83PubMedCrossRef Asik M, Sener N, Akpinar S, Durmaz H, Goksan A (1997) Strength of different meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 5(2):80–83PubMedCrossRef
6.
go back to reference Asik M, Sener N (2002) Failure strength of repair devices versus meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 10(1):25–29PubMedCrossRef Asik M, Sener N (2002) Failure strength of repair devices versus meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 10(1):25–29PubMedCrossRef
7.
go back to reference Barber FA, Herbert MA, Richards DP (2004) Load to failure testing of new meniscal repair devices. Arthroscopy 20(1):45–50PubMedCrossRef Barber FA, Herbert MA, Richards DP (2004) Load to failure testing of new meniscal repair devices. Arthroscopy 20(1):45–50PubMedCrossRef
8.
go back to reference Bellemans J, Vandenneucker H, Labey L, Van Audekercke R (2002) Fixation strength of meniscal repair devices. Knee 9(1):11–14PubMedCrossRef Bellemans J, Vandenneucker H, Labey L, Van Audekercke R (2002) Fixation strength of meniscal repair devices. Knee 9(1):11–14PubMedCrossRef
9.
go back to reference Bonutti PM, Weiker GG, Andrish JT (1988) Isobutyl cyanoacrylate as a soft tissue adhesive. An in vitro study in the rabbit Achilles tendon. Clin Orthop Relat Res 229:241–248PubMed Bonutti PM, Weiker GG, Andrish JT (1988) Isobutyl cyanoacrylate as a soft tissue adhesive. An in vitro study in the rabbit Achilles tendon. Clin Orthop Relat Res 229:241–248PubMed
10.
go back to reference Cheski PJ, Matthews TW (1997) Endoscopic reduction and internal cyanoacrylate fixation of the zygoma. J Otolaryngol 26(2):75–79PubMed Cheski PJ, Matthews TW (1997) Endoscopic reduction and internal cyanoacrylate fixation of the zygoma. J Otolaryngol 26(2):75–79PubMed
11.
go back to reference Arendt Elizabeth A (ed) (1999) Orthopaedic knowledge update sports medicine 2. In: Luc Teurlings, Meniscal Injuries. American Academy of Orthopaedic Surgeon, Ilinois, pp 349–353 Arendt Elizabeth A (ed) (1999) Orthopaedic knowledge update sports medicine 2. In: Luc Teurlings, Meniscal Injuries. American Academy of Orthopaedic Surgeon, Ilinois, pp 349–353
12.
go back to reference Farng E, Sherman O (2004) Meniscal repair devices: a clinical and biomechanical literature review. Arthroscopy 20(3):273–286. ReviewPubMedCrossRef Farng E, Sherman O (2004) Meniscal repair devices: a clinical and biomechanical literature review. Arthroscopy 20(3):273–286. ReviewPubMedCrossRef
13.
go back to reference Fisher SR, Markel DC, Koman JD (2002) Atkinson TS. Pull-out and shear failure strengths of arthroscopic meniscal repair systems. Knee Surg Sports Traumatol Arthrosc 10(5):294–299PubMed Fisher SR, Markel DC, Koman JD (2002) Atkinson TS. Pull-out and shear failure strengths of arthroscopic meniscal repair systems. Knee Surg Sports Traumatol Arthrosc 10(5):294–299PubMed
14.
go back to reference Jakob RP, Staubli HU, Zuber K, Esser M (1988) The arthroscopic meniscal repair. Techniques and clinical experience. Am J Sports Med 16(2):137–142PubMed Jakob RP, Staubli HU, Zuber K, Esser M (1988) The arthroscopic meniscal repair. Techniques and clinical experience. Am J Sports Med 16(2):137–142PubMed
15.
go back to reference Buckwalter Joseph A, Einhorn Thomas A, Simon Sheldon R (eds) (2000) Orthopaedic basic science: biology and biomechanics of the musculoskeletal system. In: Arnoczky Steven P, McDevitt Cahir A (eds) The meniscus: structure, function, repair, and replacement. American Academy of Orthopaedic Surgeon, Ilinois, pp 531–545 Buckwalter Joseph A, Einhorn Thomas A, Simon Sheldon R (eds) (2000) Orthopaedic basic science: biology and biomechanics of the musculoskeletal system. In: Arnoczky Steven P, McDevitt Cahir A (eds) The meniscus: structure, function, repair, and replacement. American Academy of Orthopaedic Surgeon, Ilinois, pp 531–545
16.
go back to reference Kimura M, Shirakura K, Hasegawa A, Kobuna Y, Niijima M (1995) Second look arthroscopy after meniscal repair. Factors affecting the healing rate. Clin Orthop Relat Res 314:185–191PubMed Kimura M, Shirakura K, Hasegawa A, Kobuna Y, Niijima M (1995) Second look arthroscopy after meniscal repair. Factors affecting the healing rate. Clin Orthop Relat Res 314:185–191PubMed
17.
go back to reference Koukoubis TD, Glisson RR, Feagin JA Jr, Seaber AV, Vail TP (1995) Augmentation of meniscal repairs with cyanoacrylate glue. J Biomed Mater Res 29(6):715–720PubMedCrossRef Koukoubis TD, Glisson RR, Feagin JA Jr, Seaber AV, Vail TP (1995) Augmentation of meniscal repairs with cyanoacrylate glue. J Biomed Mater Res 29(6):715–720PubMedCrossRef
18.
19.
20.
go back to reference Shermak MA, Wong L, Inoue N, Chao EY, Manson PN (1998) Butyl-2-cyanoacrylate fixation of mandibular osteotomies. Plast Reconstr Surg 102(2):319–324PubMedCrossRef Shermak MA, Wong L, Inoue N, Chao EY, Manson PN (1998) Butyl-2-cyanoacrylate fixation of mandibular osteotomies. Plast Reconstr Surg 102(2):319–324PubMedCrossRef
21.
go back to reference Shermak MA, Wong L, Inoue N et al (1998) Fixation of the craniofacial skeleton with butyl-2-cyanoacrylate and its effects on histotoxicity and healing. Plast Reconstr Surg 102(2):309–318PubMedCrossRef Shermak MA, Wong L, Inoue N et al (1998) Fixation of the craniofacial skeleton with butyl-2-cyanoacrylate and its effects on histotoxicity and healing. Plast Reconstr Surg 102(2):309–318PubMedCrossRef
22.
go back to reference Trail IA, Powell ES, Noble J, Crank S (1992) The role of an adhesive (Histoacryl) in tendon repair. J Hand Surg [Br] 17(5):544–549CrossRef Trail IA, Powell ES, Noble J, Crank S (1992) The role of an adhesive (Histoacryl) in tendon repair. J Hand Surg [Br] 17(5):544–549CrossRef
23.
go back to reference Vihtonen K, Vainionpaa S, Mero M et al (1986) Fixation of experimental osteotomies of the distal femur in rabbits with bone cement and cyanoacrylate. Arch Orthop Trauma Surg 105(3):133–136PubMedCrossRef Vihtonen K, Vainionpaa S, Mero M et al (1986) Fixation of experimental osteotomies of the distal femur in rabbits with bone cement and cyanoacrylate. Arch Orthop Trauma Surg 105(3):133–136PubMedCrossRef
24.
go back to reference Yilmaz C, Kuyurtar F (2005) Fixation of a talar osteochondral fracture with cyanoacrylate glue. Arthroscopy 21(8):1009PubMedCrossRef Yilmaz C, Kuyurtar F (2005) Fixation of a talar osteochondral fracture with cyanoacrylate glue. Arthroscopy 21(8):1009PubMedCrossRef
25.
go back to reference Zhao C, Amadio PC, Tanaka T et al (2004) Effect of gap size on gliding resistance after flexor tendon repair. J Bone Joint Surg Am 86-A(11):2482–2488PubMed Zhao C, Amadio PC, Tanaka T et al (2004) Effect of gap size on gliding resistance after flexor tendon repair. J Bone Joint Surg Am 86-A(11):2482–2488PubMed
Metadata
Title
Histoacryl glue in meniscal repairs (a biomechanical study)
Authors
Irfan Ayan
Mehmet Colak
Ulku Comelekoglu
Abtullah Milcan
Oya Ogenler
Volkan Oztuna
Fehmi Kuyurtar
Publication date
01-04-2007
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 2/2007
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0158-z

Other articles of this Issue 2/2007

International Orthopaedics 2/2007 Go to the issue