Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 5/2024

Open Access 12-04-2024 | Hip-TEP | Hip Arthroplasty

Risk factors for femoral stem fracture following total hip arthroplasty: a systematic review and meta analysis

Authors: Gareth S. Turnbull, Sam Soete, Muhammad Adeel Akhtar, James Anderson Ballantyne

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 5/2024

Login to get access

Abstract

Background

Femoral stem fracture following total hip arthroplasty (THA) is an infrequent but nevertheless devastating complication, with an increasing worldwide prevalence as demand for primary THA continues to increase. The aim of this study was to perform a systematic review and meta-analysis of risk factors for femoral stem fracture to help identify at risk patients.

Methods

A systematic search was conducted on EMBASE, MEDLINE and AMED to identify relevant studies. Data regarding study design, source, population, intervention, and outcomes was collated. Data extraction was performed on a custom form generated using Cochrane recommended methodology and analysis of risk factors performed including odds ratios (ORs) with 95% confidence intervals (CIs).

Results

A total of 15 studies reporting a total of 402 stem fractures in 49 723 THAs were identified. The median time from index procedure to stem fracture was 68 months (IQR 42.5–118) whilst mean age at index surgery was 61.8 years (SD 6.9). Male gender (OR = 3.27, 95% CI = 2.59–4.13, p < 0.001), patient weight above 80 kg (OR = 3.55, 95% CI = 2.88–4.37, p < 0.001), age under 63 years (OR = 1.22, 95% CI = 1.01–1.49, p < 0.001), varus stem alignment (OR = 5.77, 95% CI = 3.83–8.7, p < 0.001), use of modular implants (OR = 1.95, 95% CI = 1.56–2.44, p < 0.01) and undergoing revision arthroplasty (OR = 3.33, 95% CI = 2.70–4.1, p < 0.001) were significant risk factors for prosthetic stem fracture. A risk window of 15 years post-surgery was identified.

Conclusions

This review concludes that patient weight, younger age, male sex, varus stem alignment, revision arthroplasty and use of modular stems are significant risk factors for femoral stem fracture. Modifying these risk factors where possible may help reduce incidence of femoral stem fracture in at risk patients.
Literature
1.
go back to reference Lakstein D et al (2010) Revision total hip arthroplasty with a porous-coated modular stem: 5 to 10 years follow-up. Clin Orthop Relat Res 468(5):1310–1315CrossRefPubMed Lakstein D et al (2010) Revision total hip arthroplasty with a porous-coated modular stem: 5 to 10 years follow-up. Clin Orthop Relat Res 468(5):1310–1315CrossRefPubMed
2.
go back to reference Busch CA et al (2005) Fractures of distally-fixed femoral stems after revision arthroplasty. J Bone Joint Surg Br 87(10):1333–1336CrossRefPubMed Busch CA et al (2005) Fractures of distally-fixed femoral stems after revision arthroplasty. J Bone Joint Surg Br 87(10):1333–1336CrossRefPubMed
3.
go back to reference Heck DA et al (1995) Prosthetic component failures in hip arthroplasty surgery. J Arthroplasty 10(5):575–580CrossRefPubMed Heck DA et al (1995) Prosthetic component failures in hip arthroplasty surgery. J Arthroplasty 10(5):575–580CrossRefPubMed
4.
go back to reference Malchau H et al (2002) The Swedish Total Hip Replacement Register. J Bone Joint Surg Am 84-A(Suppl 2):2–20CrossRef Malchau H et al (2002) The Swedish Total Hip Replacement Register. J Bone Joint Surg Am 84-A(Suppl 2):2–20CrossRef
5.
go back to reference Martens M et al (1974) Factors in the mechanical failure of the femoral component in total hip prosthesis. report of six fatigue fractures of the femoral stem and results of experimental loading tests. Acta Orthop Scand 45(5):693–710CrossRefPubMed Martens M et al (1974) Factors in the mechanical failure of the femoral component in total hip prosthesis. report of six fatigue fractures of the femoral stem and results of experimental loading tests. Acta Orthop Scand 45(5):693–710CrossRefPubMed
6.
go back to reference Köksal A et al (2020) Femoral stem fractures after primary and revision hip replacements: a single-center experience. Jt Dis Relat Surg 31(3):557–563PubMedPubMedCentral Köksal A et al (2020) Femoral stem fractures after primary and revision hip replacements: a single-center experience. Jt Dis Relat Surg 31(3):557–563PubMedPubMedCentral
7.
go back to reference Kurtz S et al (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone J Surg Am 89(4):780–785CrossRef Kurtz S et al (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone J Surg Am 89(4):780–785CrossRef
9.
go back to reference Yates PJ et al (2008) Fractures of modern high nitrogen stainless steel cemented stems: cause, mechanism, and avoidance in 14 cases. J Arthroplasty 23(2):188–196CrossRefPubMed Yates PJ et al (2008) Fractures of modern high nitrogen stainless steel cemented stems: cause, mechanism, and avoidance in 14 cases. J Arthroplasty 23(2):188–196CrossRefPubMed
10.
go back to reference Wheeler K, James L (1971) Fatigue behavior of type 316 stainless steel under simulated body conditions. J Biomed Mater Res 5(3):267–281CrossRefPubMed Wheeler K, James L (1971) Fatigue behavior of type 316 stainless steel under simulated body conditions. J Biomed Mater Res 5(3):267–281CrossRefPubMed
11.
go back to reference Wroblewski BM (1979) The mechanism of fracture of the femoral prosthesis in total hip replacement. Int Orthop 3(2):137–139CrossRefPubMed Wroblewski BM (1979) The mechanism of fracture of the femoral prosthesis in total hip replacement. Int Orthop 3(2):137–139CrossRefPubMed
13.
go back to reference Amin AK et al (2006) Does obesity influence the clinical outcome at five years following total knee replacement for osteoarthritis? J Bone Joint Surg Br 88(3):335–340CrossRefPubMed Amin AK et al (2006) Does obesity influence the clinical outcome at five years following total knee replacement for osteoarthritis? J Bone Joint Surg Br 88(3):335–340CrossRefPubMed
14.
go back to reference Turnbull GS et al (2019) Return to activity following revision total hip arthroplasty. Arch Orthop Trauma Surg 139(3):411–421CrossRefPubMed Turnbull GS et al (2019) Return to activity following revision total hip arthroplasty. Arch Orthop Trauma Surg 139(3):411–421CrossRefPubMed
15.
go back to reference C.A.S.P. (2023) CASP (systematic reviews) checklist C.A.S.P. (2023) CASP (systematic reviews) checklist
16.
go back to reference Krueger DR et al (2020) Mechanical failure of 113 uncemented modular revision femoral components. Bone Joint J 102-b(5):573–579CrossRefPubMed Krueger DR et al (2020) Mechanical failure of 113 uncemented modular revision femoral components. Bone Joint J 102-b(5):573–579CrossRefPubMed
17.
go back to reference Herold F, Nötzli H, Eijer H (2021) Short proximal components in modular revision stems carry a higher risk for stem fractures. Hip Int 31(3):398–403CrossRefPubMed Herold F, Nötzli H, Eijer H (2021) Short proximal components in modular revision stems carry a higher risk for stem fractures. Hip Int 31(3):398–403CrossRefPubMed
18.
go back to reference Amstutz HC et al (1990) Stem fracture incidence in trapezoidal-28 stainless steel hip arthroplasty. Clin Orthop Relat Res 256:105–114CrossRef Amstutz HC et al (1990) Stem fracture incidence in trapezoidal-28 stainless steel hip arthroplasty. Clin Orthop Relat Res 256:105–114CrossRef
19.
go back to reference Shah RR et al (2017) Alarmingly high rate of implant fractures in one modular femoral stem design: a comparison of two implants. J Arthroplasty 32(10):3157–3162CrossRefPubMed Shah RR et al (2017) Alarmingly high rate of implant fractures in one modular femoral stem design: a comparison of two implants. J Arthroplasty 32(10):3157–3162CrossRefPubMed
20.
go back to reference Røkkum M et al (1995) Stem fracture with the exeter prosthesis. 3 of 27 hips followed for 10 years. Acta Orthop Scand 66(5):435–439CrossRefPubMed Røkkum M et al (1995) Stem fracture with the exeter prosthesis. 3 of 27 hips followed for 10 years. Acta Orthop Scand 66(5):435–439CrossRefPubMed
21.
go back to reference Kishida Y et al (2002) Stem fracture of the cementless spongy metal Lübeck hip prosthesis. J Arthroplasty 17(8):1021–1027CrossRefPubMed Kishida Y et al (2002) Stem fracture of the cementless spongy metal Lübeck hip prosthesis. J Arthroplasty 17(8):1021–1027CrossRefPubMed
22.
go back to reference Matar HE et al (2020) Fractured femoral stems in primary and revision hip arthroplasties revisited: Wrightington experience. J Arthroplasty 35(5):1344–1350CrossRefPubMed Matar HE et al (2020) Fractured femoral stems in primary and revision hip arthroplasties revisited: Wrightington experience. J Arthroplasty 35(5):1344–1350CrossRefPubMed
23.
go back to reference Merini A et al (2016) Cementless Corail™ femoral stems with laser neck etching: long-term survival, rupture rate and risk factors in 295 stems. Orthop Traumatol Surg Res 102(1):71–76CrossRefPubMed Merini A et al (2016) Cementless Corail™ femoral stems with laser neck etching: long-term survival, rupture rate and risk factors in 295 stems. Orthop Traumatol Surg Res 102(1):71–76CrossRefPubMed
24.
go back to reference Pazzaglia UE et al (1988) Failure of the stem in total hip replacement. a study of aetiology and mechanism of failure in 13 cases (1978). Arch Orthop Trauma Surg 107(4):195–202CrossRefPubMed Pazzaglia UE et al (1988) Failure of the stem in total hip replacement. a study of aetiology and mechanism of failure in 13 cases (1978). Arch Orthop Trauma Surg 107(4):195–202CrossRefPubMed
25.
go back to reference Ritter MA, Campbell ED (1987) Long-term comparison of the Charnley, Muller, and trapezoidal-28 total hip prostheses. A survival analysis. J Arthroplasty 2(4):299–308CrossRefPubMed Ritter MA, Campbell ED (1987) Long-term comparison of the Charnley, Muller, and trapezoidal-28 total hip prostheses. A survival analysis. J Arthroplasty 2(4):299–308CrossRefPubMed
26.
go back to reference Vanbiervliet J et al (2022) High rates of implant fracture of a generic polished tapered femoral stem. Hip Int 32(1):99–105CrossRefPubMed Vanbiervliet J et al (2022) High rates of implant fracture of a generic polished tapered femoral stem. Hip Int 32(1):99–105CrossRefPubMed
27.
go back to reference Markolf KL, Amstutz HC (1976) A comparative experimental study of stresses in femoral total hip replacement components: the effects of prosthesis orientation and acrylic fixation. J Biomech 9(2):73–79CrossRefPubMed Markolf KL, Amstutz HC (1976) A comparative experimental study of stresses in femoral total hip replacement components: the effects of prosthesis orientation and acrylic fixation. J Biomech 9(2):73–79CrossRefPubMed
29.
go back to reference Fink B, Urbansky K, Schuster P (2014) Mid term results with the curved modular tapered, fluted titanium Revitan stem in revision hip replacement. Bone Joint J 96-B(7):889–895CrossRefPubMed Fink B, Urbansky K, Schuster P (2014) Mid term results with the curved modular tapered, fluted titanium Revitan stem in revision hip replacement. Bone Joint J 96-B(7):889–895CrossRefPubMed
30.
go back to reference Ling R (2004) The history and development of the Exeter hip. Stryker, Montreux, Switzerland Ling R (2004) The history and development of the Exeter hip. Stryker, Montreux, Switzerland
Metadata
Title
Risk factors for femoral stem fracture following total hip arthroplasty: a systematic review and meta analysis
Authors
Gareth S. Turnbull
Sam Soete
Muhammad Adeel Akhtar
James Anderson Ballantyne
Publication date
12-04-2024
Publisher
Springer Berlin Heidelberg
Keywords
Hip-TEP
Hip-TEP
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 5/2024
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-024-05281-x

Other articles of this Issue 5/2024

Archives of Orthopaedic and Trauma Surgery 5/2024 Go to the issue