Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 5/2010

01-05-2010 | Symposium: Current Issues in Knee Reconstruction

Hinged Total Knee Arthroplasty in the Presence of Ligamentous Deficiency

Authors: Daniel Hernández-Vaquero, PhD, Manuel A. Sandoval-García, PhD

Published in: Clinical Orthopaedics and Related Research® | Issue 5/2010

Login to get access

Abstract

Background

Rotating-hinge total knee prostheses may be used for the treatment of global instability about the knee. The designs of previous generations were associated with suboptimal outcomes.

Questions/purposes

We evaluated the clinical and radiographic outcomes of salvage knee reconstructions using modern-generation, modular, kinematic rotating-hinge total knee prostheses.

Methods

We retrospectively reviewed 26 rotating-hinge arthroplasty devices to examine whether acceptable results were obtainable using a single arthroplasty design. The average age of the patients was 77 years (SD, 9 years); the minimum followup was 24 months (mean, 46 months; range, 24–107 months). The indication was revision surgery in 21 patients and complex primary surgery in five. Patients were evaluated clinically (Knee Society score) and radiographically (positions of components, signs of loosening, bone loss).

Results

Knee Society pain scores improved from 40 preoperatively to 77 postoperatively, and function scores improved from 36 to 51. ROM improved from –15º to –10º. None of the patients’ knee pain or function worsened. No loosening of implants was observed. Nonprogressive radiolucent lines were identified around the femoral and tibial components in three knees. Three patients required reoperations: one showed a supracondylar periprosthetic fracture treated by open reduction and internal fixation, whereas the other two had periprosthetic infections.

Conclusions

Reconstruction with rotating-hinge total knee prostheses can provide substantial improvement in function and a reduction in pain in extreme circumstances, such as gross instability. We believe this salvage procedure should be reserved for severe ligamentous deficiencies in elderly and sedentary patients or whenever revision surgery techniques fail.

Level of Evidence

Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Anderson JA, Baldini A, MacDonald JH, Pellicci PM, Sculco TP. Primary constrained condylar knee arthroplasty without stems extensions for the valgus knee. Clin Orthop Relat Res. 2006;442:199–203.CrossRefPubMed Anderson JA, Baldini A, MacDonald JH, Pellicci PM, Sculco TP. Primary constrained condylar knee arthroplasty without stems extensions for the valgus knee. Clin Orthop Relat Res. 2006;442:199–203.CrossRefPubMed
2.
go back to reference Barrack RL. Evolution of the rotating hinge for complex total knee arthroplasty. Clin Orthop Relat Res. 2001;392:292–299.CrossRefPubMed Barrack RL. Evolution of the rotating hinge for complex total knee arthroplasty. Clin Orthop Relat Res. 2001;392:292–299.CrossRefPubMed
3.
go back to reference Barrack RL. Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics. 2002;25:1020, 1058. Barrack RL. Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics. 2002;25:1020, 1058.
4.
go back to reference Barrack RL, Lyons TR, Ingraham RQ, Johnson JC. The use of a modular rotating hinge component in salvage revision total knee arthroplasty. J Arthroplasty. 2000;15:858–866.CrossRefPubMed Barrack RL, Lyons TR, Ingraham RQ, Johnson JC. The use of a modular rotating hinge component in salvage revision total knee arthroplasty. J Arthroplasty. 2000;15:858–866.CrossRefPubMed
5.
go back to reference Berend KR, Lombardi AV Jr. Distal femoral replacement in nontumor cases with severe bone loss and instability. Clin Orthop Relat Res. 2009;467:485–492.CrossRefPubMed Berend KR, Lombardi AV Jr. Distal femoral replacement in nontumor cases with severe bone loss and instability. Clin Orthop Relat Res. 2009;467:485–492.CrossRefPubMed
6.
go back to reference Böhm P, Holy T. Is there a future for hinged prostheses in primary total knee arthroplasty? J Bone Joint Surg Br. 1998;80:302–309.CrossRefPubMed Böhm P, Holy T. Is there a future for hinged prostheses in primary total knee arthroplasty? J Bone Joint Surg Br. 1998;80:302–309.CrossRefPubMed
7.
go back to reference Deehan DJ, Murray J, Birdsall PD, Holland JP, Pinder IM. The role of the rotating hinge prosthesis in the salvage arthroplasty setting. J Arthroplasty. 2008;23:683–688.CrossRefPubMed Deehan DJ, Murray J, Birdsall PD, Holland JP, Pinder IM. The role of the rotating hinge prosthesis in the salvage arthroplasty setting. J Arthroplasty. 2008;23:683–688.CrossRefPubMed
8.
go back to reference Hartford JM, Goodman SB, Schurman DJ, Knoblick G. Complex primary and revision total knee arthroplasty using the condylar constrained prosthesis: an average 5-year follow-up. J Arthroplasty. 1998;13:380–387.CrossRefPubMed Hartford JM, Goodman SB, Schurman DJ, Knoblick G. Complex primary and revision total knee arthroplasty using the condylar constrained prosthesis: an average 5-year follow-up. J Arthroplasty. 1998;13:380–387.CrossRefPubMed
9.
go back to reference Huff TW, Sculco TP. Management of bone loss in revision total knee arthroplasty. J Arthroplasty. 2007;22(7 Suppl 3):32–36.CrossRefPubMed Huff TW, Sculco TP. Management of bone loss in revision total knee arthroplasty. J Arthroplasty. 2007;22(7 Suppl 3):32–36.CrossRefPubMed
10.
go back to reference Joshi N, Navarro-Quilis A. Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening? J Arthroplasty. 2008;23:1204–1211.CrossRefPubMed Joshi N, Navarro-Quilis A. Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening? J Arthroplasty. 2008;23:1204–1211.CrossRefPubMed
11.
go back to reference Kester MA, Cook SD, Harding AF, Rodriguez RP, Pipkin CS. An evaluation of the mechanical failure modalities of a rotating hinge knee prosthesis. Clin Orthop Relat Res. 1988;228:156–163.PubMed Kester MA, Cook SD, Harding AF, Rodriguez RP, Pipkin CS. An evaluation of the mechanical failure modalities of a rotating hinge knee prosthesis. Clin Orthop Relat Res. 1988;228:156–163.PubMed
12.
go back to reference McAuley JP, Engh GA. Constraint in total knee arthroplasty: when and what? J Arthroplasty. 2003;18:51–54.CrossRefPubMed McAuley JP, Engh GA. Constraint in total knee arthroplasty: when and what? J Arthroplasty. 2003;18:51–54.CrossRefPubMed
13.
go back to reference Nelson CL, Lonner JH, Rand JA, Lotke PA. Strategies of stems fixation and the role of supplemental bone graft in revision total knee arthroplasty. J Bone Joint Surg Am. 2003;85(Suppl 1):S52–S57.PubMed Nelson CL, Lonner JH, Rand JA, Lotke PA. Strategies of stems fixation and the role of supplemental bone graft in revision total knee arthroplasty. J Bone Joint Surg Am. 2003;85(Suppl 1):S52–S57.PubMed
14.
go back to reference Parsley BS, Sugano N, Bertolusso R, Conditt MA. Mechanical alignment of tibial stems in revision total knee arthroplasty. J Arthroplasty. 2003;18(7 Suppl 1):33–36.CrossRefPubMed Parsley BS, Sugano N, Bertolusso R, Conditt MA. Mechanical alignment of tibial stems in revision total knee arthroplasty. J Arthroplasty. 2003;18(7 Suppl 1):33–36.CrossRefPubMed
15.
go back to reference Petrou G, Petrou H, Tilkeridis C, Stavrakis T, Kapetsis T, Kremmidas N, Gavras M. Medium-term results with a primary cemented rotating-hinge total knee replacement: a 7- to 15-year follow-up. J Bone Joint Surg Br. 2004;86:813–817.CrossRefPubMed Petrou G, Petrou H, Tilkeridis C, Stavrakis T, Kapetsis T, Kremmidas N, Gavras M. Medium-term results with a primary cemented rotating-hinge total knee replacement: a 7- to 15-year follow-up. J Bone Joint Surg Br. 2004;86:813–817.CrossRefPubMed
16.
go back to reference Pour AE, Parvizi J, Slenker N, Purtill JJ, Sharkey PF. Rotating hinged total knee replacement: use with caution. J Bone Joint Surg Am. 2007;89:1735–1741.CrossRefPubMed Pour AE, Parvizi J, Slenker N, Purtill JJ, Sharkey PF. Rotating hinged total knee replacement: use with caution. J Bone Joint Surg Am. 2007;89:1735–1741.CrossRefPubMed
17.
go back to reference Pradhan NR, Bale L, Kay P, Porter ML Salvage revision total knee replacement using the Endo-Model rotating hinge prosthesis. Knee. 2004;11:469–473.CrossRefPubMed Pradhan NR, Bale L, Kay P, Porter ML Salvage revision total knee replacement using the Endo-Model rotating hinge prosthesis. Knee. 2004;11:469–473.CrossRefPubMed
18.
go back to reference Rand JA, Chao EY, Stauffer RN. Kinematic rotating-hinge total knee arthroplasty. J Bone Joint Surg Am. 1987;69:489–497.PubMed Rand JA, Chao EY, Stauffer RN. Kinematic rotating-hinge total knee arthroplasty. J Bone Joint Surg Am. 1987;69:489–497.PubMed
19.
go back to reference Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002;404:7–13.CrossRefPubMed Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002;404:7–13.CrossRefPubMed
20.
go back to reference Springer BD, Hanssen AD, Sim FH, Lewallen DG. The kinematic rotating hinge prosthesis for complex knee arthroplasty. Clin Orthop Relat Res. 2001;392:283–291.CrossRefPubMed Springer BD, Hanssen AD, Sim FH, Lewallen DG. The kinematic rotating hinge prosthesis for complex knee arthroplasty. Clin Orthop Relat Res. 2001;392:283–291.CrossRefPubMed
21.
go back to reference Springer BD, Sim FH, Hanssen AD, Lewallen DG. The modular segmental kinematic rotating hinge for nonneoplastic limb salvage. Clin Orthop Relat Res. 2004;421:181–187.CrossRefPubMed Springer BD, Sim FH, Hanssen AD, Lewallen DG. The modular segmental kinematic rotating hinge for nonneoplastic limb salvage. Clin Orthop Relat Res. 2004;421:181–187.CrossRefPubMed
22.
go back to reference Wang CJ, Wang HE. Early catastrophic failure of rotating hinge total knee prosthesis. J Arthroplasty. 2000;15:387–391.CrossRefPubMed Wang CJ, Wang HE. Early catastrophic failure of rotating hinge total knee prosthesis. J Arthroplasty. 2000;15:387–391.CrossRefPubMed
23.
go back to reference Westrich GH, Molano AV, Sculco TP, Buly RL, Laskin RS, Windsor R. Rotating hinge total knee arthroplasty affected knees. Clin Orthop Relat Res. 2000;379:195–208.CrossRefPubMed Westrich GH, Molano AV, Sculco TP, Buly RL, Laskin RS, Windsor R. Rotating hinge total knee arthroplasty affected knees. Clin Orthop Relat Res. 2000;379:195–208.CrossRefPubMed
Metadata
Title
Hinged Total Knee Arthroplasty in the Presence of Ligamentous Deficiency
Authors
Daniel Hernández-Vaquero, PhD
Manuel A. Sandoval-García, PhD
Publication date
01-05-2010
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 5/2010
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-1226-7

Other articles of this Issue 5/2010

Clinical Orthopaedics and Related Research® 5/2010 Go to the issue

Orthopaedic · Radiology · Pathology Conference

Chest Wall Mass in a 50-year-old Woman