Skip to main content
Top
Published in: BMC Clinical Pharmacology 1/2006

Open Access 01-12-2006 | Technical advance

High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection

Authors: Anders Andersen, David J Warren, Paal F Brunsvig, Steinar Aamdal, Gunnar B Kristensen, Harald Olsen

Published in: BMC Clinical Pharmacology | Issue 1/2006

Login to get access

Abstract

Background

The taxanes paclitaxel and docetaxel have traditionally been used in high doses every third week in the treatment of cancer. Lately there has been a trend towards giving weekly low doses to improve the therapeutic index. This article describes the development of high performance liquid chromatographic (HPLC) methods suitable for monitoring taxane levels in patients, focusing on patients receiving low-dose therapy.

Methods

Paclitaxel and docetaxel were extracted from human plasma by solid phase extraction, and detected by absorbance at 227 nm after separation by reversed phase high performance liquid chromatography. The methods were validated and their performance were tested using samples from patients receiving paclitaxel or docetaxel.

Results

The limits of quantitation were 1 nM for docetaxel and 1.2 nM for paclitaxel. For both compounds linearity was confirmed from the limit of quantitation up to 1000 nM in plasma. The recoveries ranged between 92% and 118% for docetaxel and between 76% and 104% for paclitaxel. Accuracy and precision were within international acceptance criteria, that is within ± 15%, except at the limit of quantitation where values within ± 20% are acceptable. Low-dose patients included in an on going clinical trial had a median docetaxel concentration of 2.8 nM at 72 hours post infusion. Patients receiving 100 mg/m2 of paclitaxel had a mean paclitaxel concentration of 21 nM 48 hours after the end of infusion.

Conclusion

We have developed an HPLC method using UV detection capable of quantifying 1 nM of docetaxel in plasma samples. The method should be useful for pharmacokinetic determinations at all relevant doses of docetaxel. Using a similar methodology paclitaxel can be quantified down to a concentration of 1.2 nM in plasma with acceptable accuracy and precision. We further demonstrate that the previously reported negative influence of Cremophor EL on assay performance may be overcome by degradation of the detergent by incubation with lipase.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sonnichsen DS, Relling MV: Clinical pharmacokinetics of paclitaxel. Clin Pharmacokinet. 1994, 27: 256-269.CrossRefPubMed Sonnichsen DS, Relling MV: Clinical pharmacokinetics of paclitaxel. Clin Pharmacokinet. 1994, 27: 256-269.CrossRefPubMed
2.
go back to reference Clarke SJ, Rivory LP: Clinical pharmacokinetics of docetaxel. Clin Pharmacokinet. 1999, 36: 99-114. 10.2165/00003088-199936020-00002.CrossRefPubMed Clarke SJ, Rivory LP: Clinical pharmacokinetics of docetaxel. Clin Pharmacokinet. 1999, 36: 99-114. 10.2165/00003088-199936020-00002.CrossRefPubMed
3.
go back to reference Sparreboom A, van Tellingen O, Nooijen WJ, Beijnen JH: Preclinical pharmacokinetics of paclitaxel and docetaxel. Anticancer Drugs. 1998, 9: 1-17.CrossRefPubMed Sparreboom A, van Tellingen O, Nooijen WJ, Beijnen JH: Preclinical pharmacokinetics of paclitaxel and docetaxel. Anticancer Drugs. 1998, 9: 1-17.CrossRefPubMed
4.
go back to reference Baker SD, Zhao M, He P, Carducci MA, Verweij J, Sparreboom A: Simultaneous analysis of docetaxel and the formulation vehicle polysorbate 80 in human plasma by liquid chromatography/tandem mass spectrometry. Analytical Biochemistry. 2004, 324: 276-284. 10.1016/j.ab.2003.09.038.CrossRefPubMed Baker SD, Zhao M, He P, Carducci MA, Verweij J, Sparreboom A: Simultaneous analysis of docetaxel and the formulation vehicle polysorbate 80 in human plasma by liquid chromatography/tandem mass spectrometry. Analytical Biochemistry. 2004, 324: 276-284. 10.1016/j.ab.2003.09.038.CrossRefPubMed
5.
go back to reference van Tellingen O, Beijnen JH, Verweij J, Scherrenburg EJ, Nooijen WJ, Sparreboom A: Rapid esterase-sensitive breakdown of polysorbate 80 and its impact on the plasma pharmacokinetics of docetaxel and metabolites in mice. Clin Cancer Res. 1999, 5: 2918-2924.PubMed van Tellingen O, Beijnen JH, Verweij J, Scherrenburg EJ, Nooijen WJ, Sparreboom A: Rapid esterase-sensitive breakdown of polysorbate 80 and its impact on the plasma pharmacokinetics of docetaxel and metabolites in mice. Clin Cancer Res. 1999, 5: 2918-2924.PubMed
6.
go back to reference Rischin D, Webster LK, Millward MJ, Linahan BM, Toner GC, Woollett AM, Morton CG, Bishop JF: Cremophor pharmacokinetics in patients receiving 3-, 6-, and 24-hour infusions of paclitaxel. J Natl Cancer Inst. 1996, 88: 1297-1301.CrossRefPubMed Rischin D, Webster LK, Millward MJ, Linahan BM, Toner GC, Woollett AM, Morton CG, Bishop JF: Cremophor pharmacokinetics in patients receiving 3-, 6-, and 24-hour infusions of paclitaxel. J Natl Cancer Inst. 1996, 88: 1297-1301.CrossRefPubMed
7.
go back to reference Meerum TJ, van Tellingen O, Nannan PV, Huizing MT, Schellens JH, Ten Bokkel Huinink WW, Boschma MU, Giaccone G, Veenhof CH, Beijnen JH: Cremophor EL pharmacokinetics in a phase I study of paclitaxel (Taxol) and carboplatin in non-small cell lung cancer patients. Anticancer Drugs. 2000, 11: 687-694.CrossRef Meerum TJ, van Tellingen O, Nannan PV, Huizing MT, Schellens JH, Ten Bokkel Huinink WW, Boschma MU, Giaccone G, Veenhof CH, Beijnen JH: Cremophor EL pharmacokinetics in a phase I study of paclitaxel (Taxol) and carboplatin in non-small cell lung cancer patients. Anticancer Drugs. 2000, 11: 687-694.CrossRef
8.
go back to reference Brouwer E, Verweij J, Hauns B, Loos WJ, Nooter K, Mross K, Stoter G, Sparreboom A: Linearized colorimetric assay for cremophor EL: application to pharmacokinetics after 1-hour paclitaxel infusions. Anal Biochem. 1998, 261: 198-202. 10.1006/abio.1998.2746.CrossRefPubMed Brouwer E, Verweij J, Hauns B, Loos WJ, Nooter K, Mross K, Stoter G, Sparreboom A: Linearized colorimetric assay for cremophor EL: application to pharmacokinetics after 1-hour paclitaxel infusions. Anal Biochem. 1998, 261: 198-202. 10.1006/abio.1998.2746.CrossRefPubMed
9.
go back to reference van Zuylen L, Gianni L, Verweij J, Mross K, Brouwer E, Loos WJ, Sparreboom A: Inter-relationships of paclitaxel disposition, infusion duration and cremophor EL kinetics in cancer patients. Anticancer Drugs. 2000, 11: 331-337. 10.1097/00001813-200006000-00003.CrossRefPubMed van Zuylen L, Gianni L, Verweij J, Mross K, Brouwer E, Loos WJ, Sparreboom A: Inter-relationships of paclitaxel disposition, infusion duration and cremophor EL kinetics in cancer patients. Anticancer Drugs. 2000, 11: 331-337. 10.1097/00001813-200006000-00003.CrossRefPubMed
10.
go back to reference van Tellingen O, Huizing MT, Panday VR, Schellens JH, Nooijen WJ, Beijnen JH: Cremophor EL causes (pseudo-) non-linear pharmacokinetics of paclitaxel in patients. Br J Cancer. 1999, 81: 330-335. 10.1038/sj.bjc.6690696.CrossRefPubMed van Tellingen O, Huizing MT, Panday VR, Schellens JH, Nooijen WJ, Beijnen JH: Cremophor EL causes (pseudo-) non-linear pharmacokinetics of paclitaxel in patients. Br J Cancer. 1999, 81: 330-335. 10.1038/sj.bjc.6690696.CrossRefPubMed
11.
go back to reference Huizing MT, Rosing H, Koopmans FP, Beijnen JH: Influence of Cremophor EL on the quantification of paclitaxel in plasma using high-performance liquid chromatography with solid-phase extraction as sample pretreatment. J Chromatogr B Biomed Sci Appl. 1998, 709: 161-165. 10.1016/S0378-4347(98)00043-7.CrossRefPubMed Huizing MT, Rosing H, Koopmans FP, Beijnen JH: Influence of Cremophor EL on the quantification of paclitaxel in plasma using high-performance liquid chromatography with solid-phase extraction as sample pretreatment. J Chromatogr B Biomed Sci Appl. 1998, 709: 161-165. 10.1016/S0378-4347(98)00043-7.CrossRefPubMed
12.
go back to reference Willey TA, Bekos EJ, Gaver RC, Duncan GF, Tay LK, Beijnen JH, Farmen RH: High-performance liquid chromatographic procedure for the quantitative determination of paclitaxel (Taxol) in human plasma. J Chromatogr. 1993, 621: 231-238.CrossRefPubMed Willey TA, Bekos EJ, Gaver RC, Duncan GF, Tay LK, Beijnen JH, Farmen RH: High-performance liquid chromatographic procedure for the quantitative determination of paclitaxel (Taxol) in human plasma. J Chromatogr. 1993, 621: 231-238.CrossRefPubMed
13.
go back to reference Sparreboom A, de Bruijn P, Nooter K, Loos WJ, Stoter G, Verweij J: Determination of paclitaxel in human plasma using single solvent extraction prior to isocratic reversed-phase high-performance liquid chromatography with ultraviolet detection. J Chromatogr B Biomed Sci Appl. 1998, 705: 159-164. 10.1016/S0378-4347(97)00502-1.CrossRefPubMed Sparreboom A, de Bruijn P, Nooter K, Loos WJ, Stoter G, Verweij J: Determination of paclitaxel in human plasma using single solvent extraction prior to isocratic reversed-phase high-performance liquid chromatography with ultraviolet detection. J Chromatogr B Biomed Sci Appl. 1998, 705: 159-164. 10.1016/S0378-4347(97)00502-1.CrossRefPubMed
14.
go back to reference Loos WJ, Verweij J, Nooter K, Stoter G, Sparreboom A: Sensitive determination of docetaxel in human plasma by liquid-liquid extraction and reversed-phase high-performance liquid chromatography. J Chromatogr B Biomed Sci Appl. 1997, 693: 437-441. 10.1016/S0378-4347(97)00089-3.CrossRefPubMed Loos WJ, Verweij J, Nooter K, Stoter G, Sparreboom A: Sensitive determination of docetaxel in human plasma by liquid-liquid extraction and reversed-phase high-performance liquid chromatography. J Chromatogr B Biomed Sci Appl. 1997, 693: 437-441. 10.1016/S0378-4347(97)00089-3.CrossRefPubMed
15.
go back to reference Ciccolini J, Catalin J, Blachon MF, Durand A: Rapid high-performance liquid chromatographic determination of docetaxel (Taxotere) in plasma using liquid-liquid extraction. J Chromatogr B Biomed Sci Appl. 2001, 759: 299-306. 10.1016/S0378-4347(01)00238-9.CrossRefPubMed Ciccolini J, Catalin J, Blachon MF, Durand A: Rapid high-performance liquid chromatographic determination of docetaxel (Taxotere) in plasma using liquid-liquid extraction. J Chromatogr B Biomed Sci Appl. 2001, 759: 299-306. 10.1016/S0378-4347(01)00238-9.CrossRefPubMed
16.
go back to reference Parise RA, Ramanathan RK, Zamboni WC, Egorin MJ: Sensitive liquid chromatography-mass spectrometry assay for quantitation of docetaxel and paclitaxel in human plasma. Journal of Chromatography B. 2003, 783: 231-236. 10.1016/S1570-0232(02)00659-1.CrossRef Parise RA, Ramanathan RK, Zamboni WC, Egorin MJ: Sensitive liquid chromatography-mass spectrometry assay for quantitation of docetaxel and paclitaxel in human plasma. Journal of Chromatography B. 2003, 783: 231-236. 10.1016/S1570-0232(02)00659-1.CrossRef
17.
go back to reference Alexander MS, Kiser MM, Culley T, Kern JR, Dolan JW, McChesney JD, Zygmunt J, Bannister SJ: Measurement of paclitaxel in biological matrices: high-throughput liquid chromatographic-tandem mass spectrometric quantification of paclitaxel and metabolites in human and dog plasma. J Chromatogr B Analyt Technol Biomed Life Sci. 2003, 785: 253-261.CrossRefPubMed Alexander MS, Kiser MM, Culley T, Kern JR, Dolan JW, McChesney JD, Zygmunt J, Bannister SJ: Measurement of paclitaxel in biological matrices: high-throughput liquid chromatographic-tandem mass spectrometric quantification of paclitaxel and metabolites in human and dog plasma. J Chromatogr B Analyt Technol Biomed Life Sci. 2003, 785: 253-261.CrossRefPubMed
18.
go back to reference Wang LZ, Goh BC, Grigg ME, Lee SC, Khoo YM, Lee HS: A rapid and sensitive liquid chromatography/tandem mass spectrometry method for determination of docetaxel in human plasma. Rapid Commun Mass Spectrom. 2003, 17: 1548-1552. 10.1002/rcm.1091.CrossRefPubMed Wang LZ, Goh BC, Grigg ME, Lee SC, Khoo YM, Lee HS: A rapid and sensitive liquid chromatography/tandem mass spectrometry method for determination of docetaxel in human plasma. Rapid Commun Mass Spectrom. 2003, 17: 1548-1552. 10.1002/rcm.1091.CrossRefPubMed
19.
go back to reference Grozav AG, Hutson TE, Zhou X, Bukowski RM, Ganapathi R, Xu Y: Rapid analysis of docetaxel in human plasma by tandem mass spectrometry with on-line sample extraction. Journal of Pharmaceutical and Biomedical Analysis. 2004, 36: 125-131. 10.1016/j.jpba.2004.05.014.CrossRefPubMed Grozav AG, Hutson TE, Zhou X, Bukowski RM, Ganapathi R, Xu Y: Rapid analysis of docetaxel in human plasma by tandem mass spectrometry with on-line sample extraction. Journal of Pharmaceutical and Biomedical Analysis. 2004, 36: 125-131. 10.1016/j.jpba.2004.05.014.CrossRefPubMed
20.
go back to reference Gustafson DL, Long ME, Zirrolli JA, Duncan MW, Holden SN, Pierson AS, Eckhardt SG: Analysis of docetaxel pharmacokinetics in humans with the inclusion of later sampling time-points afforded by the use of a sensitive tandem LCMS assay. Cancer Chemother Pharmacol. 2003, 52: 159-166. 10.1007/s00280-003-0622-z.CrossRefPubMed Gustafson DL, Long ME, Zirrolli JA, Duncan MW, Holden SN, Pierson AS, Eckhardt SG: Analysis of docetaxel pharmacokinetics in humans with the inclusion of later sampling time-points afforded by the use of a sensitive tandem LCMS assay. Cancer Chemother Pharmacol. 2003, 52: 159-166. 10.1007/s00280-003-0622-z.CrossRefPubMed
21.
go back to reference Baker SD, Zhao M, Lee CKK, Verweij J, Zabelina Y, Brahmer JR, Wolff AC, Sparreboom A, Carducci MA: Comparative Pharmacokinetics of Weekly and Every-Three-Weeks Docetaxel. Clin Cancer Res. 2004, 10: 1976-1983. 10.1158/1078-0432.CCR-0842-03.CrossRefPubMed Baker SD, Zhao M, Lee CKK, Verweij J, Zabelina Y, Brahmer JR, Wolff AC, Sparreboom A, Carducci MA: Comparative Pharmacokinetics of Weekly and Every-Three-Weeks Docetaxel. Clin Cancer Res. 2004, 10: 1976-1983. 10.1158/1078-0432.CCR-0842-03.CrossRefPubMed
22.
go back to reference Sparreboom A, Loos WJ, Verweij J, de Vos AI, van der Burg ME, Stoter G, Nooter K: Quantitation of Cremophor EL in human plasma samples using a colorimetric dye-binding microassay. Anal Biochem. 1998, 255: 171-175. 10.1006/abio.1997.2467.CrossRefPubMed Sparreboom A, Loos WJ, Verweij J, de Vos AI, van der Burg ME, Stoter G, Nooter K: Quantitation of Cremophor EL in human plasma samples using a colorimetric dye-binding microassay. Anal Biochem. 1998, 255: 171-175. 10.1006/abio.1997.2467.CrossRefPubMed
23.
go back to reference Shah VP, Midha KK, Dighe S, McGilveray IJ, Skelly JP, Yacobi A, Layloff T, Viswanathan CT, Cook CE, McDowall RD: Analytical methods validation: bioavailability, bioequivalence and pharmacokinetic studies. Conference report. J Pharm Sci. 1992, 81: 309-312.CrossRef Shah VP, Midha KK, Dighe S, McGilveray IJ, Skelly JP, Yacobi A, Layloff T, Viswanathan CT, Cook CE, McDowall RD: Analytical methods validation: bioavailability, bioequivalence and pharmacokinetic studies. Conference report. J Pharm Sci. 1992, 81: 309-312.CrossRef
24.
go back to reference Rosing H, Lustig V, Koopman FP, ten Bokkel H, Beijnen JH: Bio-analysis of docetaxel and hydroxylated metabolites in human plasma by high-performance liquid chromatography and automated solid-phase extraction. J Chromatogr B Biomed Sci Appl. 1997, 696: 89-98. 10.1016/S0378-4347(97)00209-0.CrossRefPubMed Rosing H, Lustig V, Koopman FP, ten Bokkel H, Beijnen JH: Bio-analysis of docetaxel and hydroxylated metabolites in human plasma by high-performance liquid chromatography and automated solid-phase extraction. J Chromatogr B Biomed Sci Appl. 1997, 696: 89-98. 10.1016/S0378-4347(97)00209-0.CrossRefPubMed
25.
go back to reference Almeida AM, Castel-Branco MM, Falcao AC: Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods. Journal of Chromatography B. 2002, 774: 215-222. 10.1016/S1570-0232(02)00244-1.CrossRef Almeida AM, Castel-Branco MM, Falcao AC: Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods. Journal of Chromatography B. 2002, 774: 215-222. 10.1016/S1570-0232(02)00244-1.CrossRef
26.
go back to reference Nagaraja NV, Paliwal JK, Gupta RC: Choosing the calibration model in assay validation. J Pharm Biomed Anal. 1999, 20: 433-438. 10.1016/S0731-7085(98)00256-8.CrossRefPubMed Nagaraja NV, Paliwal JK, Gupta RC: Choosing the calibration model in assay validation. J Pharm Biomed Anal. 1999, 20: 433-438. 10.1016/S0731-7085(98)00256-8.CrossRefPubMed
27.
go back to reference Song D, Au JL: Isocratic high-performance liquid chromatographic assay of taxol in biological fluids and tissues using automated column switching. J Chromatogr B Biomed Appl. 1995, 663: 337-344. 10.1016/0378-4347(94)00456-F.CrossRefPubMed Song D, Au JL: Isocratic high-performance liquid chromatographic assay of taxol in biological fluids and tissues using automated column switching. J Chromatogr B Biomed Appl. 1995, 663: 337-344. 10.1016/0378-4347(94)00456-F.CrossRefPubMed
Metadata
Title
High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection
Authors
Anders Andersen
David J Warren
Paal F Brunsvig
Steinar Aamdal
Gunnar B Kristensen
Harald Olsen
Publication date
01-12-2006
Publisher
BioMed Central
Published in
BMC Clinical Pharmacology / Issue 1/2006
Electronic ISSN: 1472-6904
DOI
https://doi.org/10.1186/1472-6904-6-2

Other articles of this Issue 1/2006

BMC Clinical Pharmacology 1/2006 Go to the issue