High reliability of an algorithm for choice of implants in hip fracture patients

Authors: Henrik Palm, Eva Posner, Hans-Ulrik Ahler-Toftehøj, Peter Siesing, Silas Gylvin, Tobias Aasvang, Kim Holck, Kenneth Brian Holtz

Published in: International Orthopaedics | Issue 6/2013

Login to get access

Abstract

Purpose

Hip fracture treatment is controversial, with high complication rates. An algorithm for hip fracture surgery has shown reduced reoperation rates, but choice of implant is based on the commonly used fracture classifications, which were previously evaluated to be unreliable. The purpose of this study was to investigate the reliability of the algorithm.

Methods

From two hospitals, four observers (orthopaedic consultant, fellow, resident and intern) used the algorithm to classify into 15 hip fracture types [Garden type I–IV femoral neck including posterior tilt, vertical femoral neck, basocervical and Arbeitsgemeinschaft für Osteosynthesefragen (AO)-31 A1.1 to A3.3 trochanteric fractures] and to choose between five surgical procedures [parallel implants, prosthesis, two-or four-hole sliding hip screw (SHS) and intermedullary (IM) nail]. After individual assessment, each hospital made a consensus decision. Observations were performed twice, ten weeks apart, on pelvic, anteroposterior (AP) and axial X-rays from 100 consecutive patients.

Results

For fracture classification, mean kappa values were 0.60 for intra and 0.62 for interobserver variation, with interobserver variation between hospitals at 0.65. For posterior tilt, mean intraclass correlation coefficient was 0.91 for intra and 0.87 for interobserver variation. For choice of implant type, mean kappa values were 0.86 for both intra and interobserver variation. The two hospital consensus decisions chose same implant in 91 of 100 patients, giving a kappa value at 0.88.

Conclusion

Although hip fracture classification confirmed to be somewhat unreliable in this study, posterior tilt measurement and subsequent choice of implant type by the algorithm was found to be reliable, which opens up the possibility for a more standardized treatment of hip fracture patients between hospitals.
Literature
1.
go back to reference Palm H, Krasheninnikoff M, Holck K, Lemser T, Foss NB, Jacobsen S, Kehlet H, Gebuhr P (2012) A new algorithm for hip fracture surgery. Acta Orthop 83:26–30PubMedCrossRef Palm H, Krasheninnikoff M, Holck K, Lemser T, Foss NB, Jacobsen S, Kehlet H, Gebuhr P (2012) A new algorithm for hip fracture surgery. Acta Orthop 83:26–30PubMedCrossRef
2.
go back to reference Garden RS (1961) Low-angle fixation in fractures of the femoral neck. J Bone Joint Surg Br 43:647–663 Garden RS (1961) Low-angle fixation in fractures of the femoral neck. J Bone Joint Surg Br 43:647–663
3.
go back to reference Orthopaedic Trauma Association Classification, Database and Outcomes Committee (2007) Fracture and dislocation classification compendium-2007. J Orthop Trauma 10:Suppl. Orthopaedic Trauma Association Classification, Database and Outcomes Committee (2007) Fracture and dislocation classification compendium-2007. J Orthop Trauma 10:Suppl.
4.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef
5.
go back to reference van Embden D, Rhemrev SJ, Genelin F, Meylaerts SAG, Roukema GR (2012) The reliability of a simplified Garden classification for intracapsular hip fractures. Orthop Traumatol Surg Res 98:405–408PubMedCrossRef van Embden D, Rhemrev SJ, Genelin F, Meylaerts SAG, Roukema GR (2012) The reliability of a simplified Garden classification for intracapsular hip fractures. Orthop Traumatol Surg Res 98:405–408PubMedCrossRef
6.
go back to reference van Embden D, Rhemrev SJ, Meylaerts SAG, Roukema GR (2010) The comparison of two classifications for trochanteric femur fractures: The AO/ASIF classification and the Jensen classification. Injury 41:377–381PubMedCrossRef van Embden D, Rhemrev SJ, Meylaerts SAG, Roukema GR (2010) The comparison of two classifications for trochanteric femur fractures: The AO/ASIF classification and the Jensen classification. Injury 41:377–381PubMedCrossRef
7.
go back to reference Pervez H, Parker MJ, Pryor GA, Lutchman L, Chirodian N (2002) Classification of trochanteric fracture of the proximal femur: a study of the reliability of current systems. Injury 33:713–715PubMedCrossRef Pervez H, Parker MJ, Pryor GA, Lutchman L, Chirodian N (2002) Classification of trochanteric fracture of the proximal femur: a study of the reliability of current systems. Injury 33:713–715PubMedCrossRef
8.
go back to reference Schipper IB, Steyerberg EW, Castelein RM, van Vugt AB (2001) Reliability of the AO/ASIF classification for pertrochanteric femoral fractures. Acta Orthop Scand 72:36–41PubMedCrossRef Schipper IB, Steyerberg EW, Castelein RM, van Vugt AB (2001) Reliability of the AO/ASIF classification for pertrochanteric femoral fractures. Acta Orthop Scand 72:36–41PubMedCrossRef
9.
go back to reference Parker MJ (2009) Results of internal fixation of Pauwels type-3 vertical femoral neck fractures. Letter to the editor with reply from Haidukewych GJ. Joint Surg Am 91:490–491 Parker MJ (2009) Results of internal fixation of Pauwels type-3 vertical femoral neck fractures. Letter to the editor with reply from Haidukewych GJ. Joint Surg Am 91:490–491
10.
go back to reference van Embden D, Roukema GR, Rhemrev SJ, Genelin F, Meylaerts SAG (2011) The pauwel classification for intracapsular hip fractures: is it reliable? Injury 42:1238–1240PubMedCrossRef van Embden D, Roukema GR, Rhemrev SJ, Genelin F, Meylaerts SAG (2011) The pauwel classification for intracapsular hip fractures: is it reliable? Injury 42:1238–1240PubMedCrossRef
11.
go back to reference Mallick A, Parker MJ (2004) Basal fractures of the femoral neck: intra or extracapsular. Injury 35:989–993PubMedCrossRef Mallick A, Parker MJ (2004) Basal fractures of the femoral neck: intra or extracapsular. Injury 35:989–993PubMedCrossRef
12.
13.
go back to reference Palm H, Gosvig KK, Krasheninnikoff M, Jacobsen S, Gebuhr P (2009) A new measurement for posterior tilt predicts reoperation in undisplaced femoral neck fractures. Acta Orthop 80:303–307PubMedCrossRef Palm H, Gosvig KK, Krasheninnikoff M, Jacobsen S, Gebuhr P (2009) A new measurement for posterior tilt predicts reoperation in undisplaced femoral neck fractures. Acta Orthop 80:303–307PubMedCrossRef
14.
go back to reference Bjorgul K, Novicoff WM, Saleh KJ (2011) Learning curves in hip fracture surgery. Int Orthop 35:113–119PubMedCrossRef Bjorgul K, Novicoff WM, Saleh KJ (2011) Learning curves in hip fracture surgery. Int Orthop 35:113–119PubMedCrossRef
15.
go back to reference Alho A, Benterud JG, Roenningen H, Hoeiseth A (1991) Radiographic prediction of early failure in fermoral neck fracture. Acta Orthop 62:422–426CrossRef Alho A, Benterud JG, Roenningen H, Hoeiseth A (1991) Radiographic prediction of early failure in fermoral neck fracture. Acta Orthop 62:422–426CrossRef
Metadata
Title
High reliability of an algorithm for choice of implants in hip fracture patients
Authors
Henrik Palm
Eva Posner
Hans-Ulrik Ahler-Toftehøj
Peter Siesing
Silas Gylvin
Tobias Aasvang
Kim Holck
Kenneth Brian Holtz
Publication date
01-06-2013
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 6/2013
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-1831-7

Other articles of this Issue 6/2013

International Orthopaedics 6/2013 Go to the issue