Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 3/2015

01-04-2015 | Expert's Opinion

High-energy tibial plateau fractures: external fixation versus plate fixation

Authors: Liang Yu, Zhong Fenglin

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 3/2015

Login to get access

Abstract

Objective

Whether external or plating fixation is more appropriate for high-energy tibial plateau fractures is still being disputed, our aim was to test the hypothesis whether external fixation can provide a fair outcome with fewer complications, when compared to the results with previously reported data of plating fixation for high-energy tibial plateau fractures.

Methods

An Ovid of Medline, Embase, and Cochrane Library search was conducted for the relevant English orthopedic journals, and eligible studies, including twenty-four case series and one comparative study containing 885 patients associated with 892 fractures, were enrolled.

Results

The results showed there were a higher proportion of men, open fractures, malunion, knee instability, and posttraumatic arthritis occurred in external fixation group than those in plating group (P = 0.007, P = 0.000, P = 0.024, P = 0.006, P = 0.000, respectively), while valgus deformity happened at a significantly higher rate in plate group (P = 0.014). No significant differences were found between the two groups in terms of age, Schatzker type, follow-up, mean time to union, mean range of knee motion, and rate of reoperation. With regard to the functional and radiological outcome assessment, despite what assessment tools were used, most of these studies presented less than 90 % good/excellent results in their high-energy fracture series. Besides, there was a trend for patients in plating group to have a higher risk than those in external fixation group in terms of heterotopic ossification and local irritation (1.23 vs 0.17 %, 4 vs 1.94 %, accordingly).

Conclusions

Although lack of good quality randomized control trials, there are rather enough samples supporting the current available results. Meanwhile, future multicentered, randomized, controlled studies should be implemented to test these outcomes.
Literature
1.
go back to reference Schatzker J, McBroom R, Bruce D (1979) The tibial plateau fracture. The Toronto experience 1968–1975. Clin Orthop Relat Res 138:94–104PubMed Schatzker J, McBroom R, Bruce D (1979) The tibial plateau fracture. The Toronto experience 1968–1975. Clin Orthop Relat Res 138:94–104PubMed
2.
go back to reference Fracture and dislocation compendium (1996) Orthopaedic trauma association committee for coding and classification. J Orthop Trauma 10(Suppl 1):1–154 Fracture and dislocation compendium (1996) Orthopaedic trauma association committee for coding and classification. J Orthop Trauma 10(Suppl 1):1–154
3.
go back to reference Shah SN, Karunakar MA (2006) Early wound complications after operative treatment of high energy tibial plateau fractures through two incisions. Bull NYU Hosp Jt Dis 65(2):115–119 Shah SN, Karunakar MA (2006) Early wound complications after operative treatment of high energy tibial plateau fractures through two incisions. Bull NYU Hosp Jt Dis 65(2):115–119
4.
go back to reference Chin TYP, Bardana D, Bailey M et al (2005) Functional outcome of tibial plateau fractures treated with the fine-wire fixator. Injury 36(12):1467–1475CrossRefPubMed Chin TYP, Bardana D, Bailey M et al (2005) Functional outcome of tibial plateau fractures treated with the fine-wire fixator. Injury 36(12):1467–1475CrossRefPubMed
5.
go back to reference Katsenis D, Vasilis A, Panayiotis M et al (2005) Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures. J Orthop Trauma 19(4):241–248CrossRefPubMed Katsenis D, Vasilis A, Panayiotis M et al (2005) Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures. J Orthop Trauma 19(4):241–248CrossRefPubMed
6.
go back to reference Krupp RJ, Malkani AL, Roberts CS et al (2009) Treatment of bicondylar tibia plateau fractures using locked plating versus external fixation. Orthopedics 32(8):559CrossRef Krupp RJ, Malkani AL, Roberts CS et al (2009) Treatment of bicondylar tibia plateau fractures using locked plating versus external fixation. Orthopedics 32(8):559CrossRef
7.
go back to reference Egol KA, Su E, Tejwani NC et al (2004) Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating. J Trauma 57(2):340–346CrossRefPubMed Egol KA, Su E, Tejwani NC et al (2004) Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating. J Trauma 57(2):340–346CrossRefPubMed
8.
go back to reference Spagnolo R, Pace F (2012) Management of the Schatzker VI fractures with lateral locked screw plating. Musculoskelet Surg 96(2):75–80CrossRefPubMed Spagnolo R, Pace F (2012) Management of the Schatzker VI fractures with lateral locked screw plating. Musculoskelet Surg 96(2):75–80CrossRefPubMed
9.
go back to reference Mahadeva D, Costa ML, Gaffey A (2008) Open reduction and internal fixation versus hybrid fixation for bicondylar/severe tibial plateau fractures; a systematic review of the literature. Arch Orthop Trauma Surg 128(10):1169–1175 Mahadeva D, Costa ML, Gaffey A (2008) Open reduction and internal fixation versus hybrid fixation for bicondylar/severe tibial plateau fractures; a systematic review of the literature. Arch Orthop Trauma Surg 128(10):1169–1175
10.
go back to reference Detsky AS, Naylor CD, O’Rourke K et al (1992) Incorporating variations in the quality of individual randomized trials into meta-analysis. J Clin Epidemiol 45:225–265CrossRef Detsky AS, Naylor CD, O’Rourke K et al (1992) Incorporating variations in the quality of individual randomized trials into meta-analysis. J Clin Epidemiol 45:225–265CrossRef
11.
go back to reference Ali AM, Yang L, Hashmi M et al (2001) Bicondylar tibial plateau fractures managed with the Sheffield Hybrid Fixator: biomechanical study and operative technique. Injury 32:86–91CrossRef Ali AM, Yang L, Hashmi M et al (2001) Bicondylar tibial plateau fractures managed with the Sheffield Hybrid Fixator: biomechanical study and operative technique. Injury 32:86–91CrossRef
12.
go back to reference Faldini C, Manca M, Pagkrati S et al. (2005) Surgical treatment of complex tibial plateau fractures by closed reduction and external fixation. A review of 32 consecutive cases operated. J Orthopaed Traumatol 6(4):188–193 Faldini C, Manca M, Pagkrati S et al. (2005) Surgical treatment of complex tibial plateau fractures by closed reduction and external fixation. A review of 32 consecutive cases operated. J Orthopaed Traumatol 6(4):188–193
13.
go back to reference Subasi M, Kapukaya A, Arslan H et al (2007) Outcome of open comminuted tibial plateau fractures treated using an external fixator. J Orthop Sci 12(4):347–353CrossRefPubMed Subasi M, Kapukaya A, Arslan H et al (2007) Outcome of open comminuted tibial plateau fractures treated using an external fixator. J Orthop Sci 12(4):347–353CrossRefPubMed
14.
go back to reference Babis GC, Evangelopoulos DS, Kontovazenitis P et al (2011) High energy tibial plateau fractures treated with hybrid external fixation. J Orthop Surg Res 6(1):1–7CrossRef Babis GC, Evangelopoulos DS, Kontovazenitis P et al (2011) High energy tibial plateau fractures treated with hybrid external fixation. J Orthop Surg Res 6(1):1–7CrossRef
15.
go back to reference Catagni MA, Ottaviani G, Maggioni M (2007) Treatment strategies for complex fractures of the tibial plateau with external circular fixation and limited internal fixation. J Trauma 63(5):1043–1053CrossRefPubMed Catagni MA, Ottaviani G, Maggioni M (2007) Treatment strategies for complex fractures of the tibial plateau with external circular fixation and limited internal fixation. J Trauma 63(5):1043–1053CrossRefPubMed
16.
go back to reference El Barbary H, Ghani HA, Misbah H et al (2005) Complex tibial plateau fractures treated with Ilizarov external fixator with or without minimal internal fixation. Int Orthop 29(3):182–185CrossRefPubMedCentralPubMed El Barbary H, Ghani HA, Misbah H et al (2005) Complex tibial plateau fractures treated with Ilizarov external fixator with or without minimal internal fixation. Int Orthop 29(3):182–185CrossRefPubMedCentralPubMed
17.
go back to reference Gaudinez RF, Mallik AR, Szporn M (1996) Hybrid external fixation of comminuted tibial plateau fractures. Clin Orthop Relat Res 328:203–210CrossRefPubMed Gaudinez RF, Mallik AR, Szporn M (1996) Hybrid external fixation of comminuted tibial plateau fractures. Clin Orthop Relat Res 328:203–210CrossRefPubMed
18.
go back to reference Mikulak SA, Gold SM, Zinar DM (1998) Small wire external fixation of high energy tibial plateau fractures. Clin Orthop Relat Res 356:230–238CrossRefPubMed Mikulak SA, Gold SM, Zinar DM (1998) Small wire external fixation of high energy tibial plateau fractures. Clin Orthop Relat Res 356:230–238CrossRefPubMed
19.
go back to reference Stamer DT, Schenk R, Staggers B et al (1994) Bicondylar tibial plateau fractures treated with a hybrid ring external fixator: a preliminary study. J Orthop Trauma 8(6):455–461CrossRefPubMed Stamer DT, Schenk R, Staggers B et al (1994) Bicondylar tibial plateau fractures treated with a hybrid ring external fixator: a preliminary study. J Orthop Trauma 8(6):455–461CrossRefPubMed
20.
go back to reference El-Alfy B, Othman A, Mansour E (2011) Indirect reduction and hybrid external fixation in management of comminuted tibial plateau fractures. Acta Orthop Belg 77(3):349–354PubMed El-Alfy B, Othman A, Mansour E (2011) Indirect reduction and hybrid external fixation in management of comminuted tibial plateau fractures. Acta Orthop Belg 77(3):349–354PubMed
21.
go back to reference Kataria H, Sharma N, Kanojia RK (2007) Small wire external fixation for high-energy tibial plateau fractures. J Orthop Surg (Hong Kong) 15(2):137–143 Kataria H, Sharma N, Kanojia RK (2007) Small wire external fixation for high-energy tibial plateau fractures. J Orthop Surg (Hong Kong) 15(2):137–143
22.
go back to reference Dendrinos GK, Kontos S, Katsenis D et al (1996) Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator. J Bone Joint Surg Br 78(5):710–717PubMed Dendrinos GK, Kontos S, Katsenis D et al (1996) Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator. J Bone Joint Surg Br 78(5):710–717PubMed
23.
go back to reference Yu Z, Zheng L, Zhang Y et al (2009) Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation. Eur J Med Res 14(5):200CrossRefPubMedCentralPubMed Yu Z, Zheng L, Zhang Y et al (2009) Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation. Eur J Med Res 14(5):200CrossRefPubMedCentralPubMed
24.
go back to reference Luo CF, Sun H, Zhang B et al (2010) Three-column fixation for complex tibial plateau fractures. J Orthop Trauma 24(11):683–692CrossRefPubMed Luo CF, Sun H, Zhang B et al (2010) Three-column fixation for complex tibial plateau fractures. J Orthop Trauma 24(11):683–692CrossRefPubMed
25.
go back to reference Ehlinger M, Rahme M, Moor BK et al (2012) Reliability of locked plating in tibial plateau fractures with a medial component. Orthop Traumatol Surg Res 98(2):173–179CrossRefPubMed Ehlinger M, Rahme M, Moor BK et al (2012) Reliability of locked plating in tibial plateau fractures with a medial component. Orthop Traumatol Surg Res 98(2):173–179CrossRefPubMed
26.
go back to reference Benirschke SK, Agnew SG, Mayo KA et al (1992) Immediate internal fixation of open, complex tibial plateau fractures: treatment by a standard protocol. J Orthop Trauma 6(1):78PubMed Benirschke SK, Agnew SG, Mayo KA et al (1992) Immediate internal fixation of open, complex tibial plateau fractures: treatment by a standard protocol. J Orthop Trauma 6(1):78PubMed
27.
go back to reference Chan YS, Yuan LJ, Hung SS et al (2003) Arthroscopic-assisted reduction with bilateral buttress plate fixation of complex tibial plateau fractures. Arthroscopy 19(9):974–984CrossRefPubMed Chan YS, Yuan LJ, Hung SS et al (2003) Arthroscopic-assisted reduction with bilateral buttress plate fixation of complex tibial plateau fractures. Arthroscopy 19(9):974–984CrossRefPubMed
28.
go back to reference Katsenis D, Dendrinos G, Kouris A et al (2009) Combination of fine wire fixation and limited internal fixation for high-energy tibial plateau fractures: functional results at minimum 5-year follow-up. J Orthop Trauma 23(7):493–501CrossRefPubMed Katsenis D, Dendrinos G, Kouris A et al (2009) Combination of fine wire fixation and limited internal fixation for high-energy tibial plateau fractures: functional results at minimum 5-year follow-up. J Orthop Trauma 23(7):493–501CrossRefPubMed
29.
go back to reference Barei DP, Nork SE, Mills WJ et al (2004) Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Orthop Trauma 18(10):649–657CrossRefPubMed Barei DP, Nork SE, Mills WJ et al (2004) Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Orthop Trauma 18(10):649–657CrossRefPubMed
30.
go back to reference Stannard JP, Wilson TC, Volgas DA et al (2004) The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: short-term results. J Orthop Trauma 18(8):552–558CrossRefPubMed Stannard JP, Wilson TC, Volgas DA et al (2004) The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: short-term results. J Orthop Trauma 18(8):552–558CrossRefPubMed
31.
go back to reference Rasmussen PS (1973) Tibial condylar fractures. Impairment of knee joint stability as an indication for surgical treatment. J Bone Joint Surg Am 55:1331–1350PubMed Rasmussen PS (1973) Tibial condylar fractures. Impairment of knee joint stability as an indication for surgical treatment. J Bone Joint Surg Am 55:1331–1350PubMed
32.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
33.
go back to reference Honkonen SE, Jarvinen MJ (1992) Classification of fractures of the tibial condyles. J Bone Jt Surg Br 74(6):840–847 Honkonen SE, Jarvinen MJ (1992) Classification of fractures of the tibial condyles. J Bone Jt Surg Br 74(6):840–847
34.
go back to reference Hall JA, Beuerlein MJ, McKee MD (2009) Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures surgical technique. J Bone Joint Surg Am 91(Supplement_2_Part_1):74–88 Hall JA, Beuerlein MJ, McKee MD (2009) Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures surgical technique. J Bone Joint Surg Am 91(Supplement_2_Part_1):74–88
35.
go back to reference Bugler KE, Clement ND, Duckworth AD et al (2012) The epidemiology of open fractures in adults. A 15-year review. Injury 43(6):891–897CrossRefPubMed Bugler KE, Clement ND, Duckworth AD et al (2012) The epidemiology of open fractures in adults. A 15-year review. Injury 43(6):891–897CrossRefPubMed
Metadata
Title
High-energy tibial plateau fractures: external fixation versus plate fixation
Authors
Liang Yu
Zhong Fenglin
Publication date
01-04-2015
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 3/2015
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-014-1528-7

Other articles of this Issue 3/2015

European Journal of Orthopaedic Surgery & Traumatology 3/2015 Go to the issue