Skip to main content
Top
Published in: Journal of NeuroEngineering and Rehabilitation 1/2012

Open Access 01-12-2012 | Research

High-density surface EMG maps from upper-arm and forearm muscles

Authors: Monica Rojas-Martínez, Miguel A Mañanas, Joan F Alonso

Published in: Journal of NeuroEngineering and Rehabilitation | Issue 1/2012

Login to get access

Abstract

Background

sEMG signal has been widely used in different applications in kinesiology and rehabilitation as well as in the control of human-machine interfaces. In general, the signals are recorded with bipolar electrodes located in different muscles. However, such configuration may disregard some aspects of the spatial distribution of the potentials like location of innervation zones and the manifestation of inhomogineties in the control of the muscular fibers. On the other hand, the spatial distribution of motor unit action potentials has recently been assessed with activation maps obtained from High Density EMG signals (HD-EMG), these lasts recorded with arrays of closely spaced electrodes. The main objective of this work is to analyze patterns in the activation maps, associating them with four movement directions at the elbow joint and with different strengths of those tasks. Although the activation pattern can be assessed with bipolar electrodes, HD-EMG maps could enable the extraction of features that depend on the spatial distribution of the potentials and on the load-sharing between muscles, in order to have a better differentiation between tasks and effort levels.

Methods

An experimental protocol consisting of isometric contractions at three levels of effort during flexion, extension, supination and pronation at the elbow joint was designed and HD-EMG signals were recorded with 2D electrode arrays on different upper-limb muscles. Techniques for the identification and interpolation of artifacts are explained, as well as a method for the segmentation of the activation areas. In addition, variables related to the intensity and spatial distribution of the maps were obtained, as well as variables associated to signal power of traditional single bipolar recordings. Finally, statistical tests were applied in order to assess differences between information extracted from single bipolar signals or from HD-EMG maps and to analyze differences due to type of task and effort level.

Results

Significant differences were observed between EMG signal power obtained from single bipolar configuration and HD-EMG and better results regarding the identification of tasks and effort levels were obtained with the latter. Additionally, average maps for a population of 12 subjects were obtained and differences in the co-activation pattern of muscles were found not only from variables related to the intensity of the maps but also to their spatial distribution.

Conclusions

Intensity and spatial distribution of HD-EMG maps could be useful in applications where the identification of movement intention and its strength is needed, for example in robotic-aided therapies or for devices like powered- prostheses or orthoses. Finally, additional data transformations or other features are necessary in order to improve the performance of tasks identification.
Appendix
Available only for authorised users
Literature
1.
go back to reference Nishikawa D, Wenwei Y, Yokoi H, Kakazu Y: EMG prosthetic hand controller using real-time learning method. Proc IEEE Int Conf Syst Man Cybern 1999, 1: 153-158. Nishikawa D, Wenwei Y, Yokoi H, Kakazu Y: EMG prosthetic hand controller using real-time learning method. Proc IEEE Int Conf Syst Man Cybern 1999, 1: 153-158.
2.
go back to reference Dipietro L, Ferraro M, Palazzolo JJ, Krebs HI, Volpe BT, Hogan N: Customized interactive robotic treatment for stroke: EMG-triggered therapy. IEEE Trans Neural Syst Rehabil Eng 2005,13(3):325-334. 10.1109/TNSRE.2005.850423PubMedCentralCrossRefPubMed Dipietro L, Ferraro M, Palazzolo JJ, Krebs HI, Volpe BT, Hogan N: Customized interactive robotic treatment for stroke: EMG-triggered therapy. IEEE Trans Neural Syst Rehabil Eng 2005,13(3):325-334. 10.1109/TNSRE.2005.850423PubMedCentralCrossRefPubMed
3.
go back to reference Drost G, Stegeman DF, Schillings ML, Horemans HLD, Janssen HMHA, Massa M, et al.: Motor unit characteristics in healthy subjects and those with postpoliomyelitis syndrome: A high-density surface EMG study. Muscle Nerve 2004,30(3):269-276. 10.1002/mus.20104CrossRefPubMed Drost G, Stegeman DF, Schillings ML, Horemans HLD, Janssen HMHA, Massa M, et al.: Motor unit characteristics in healthy subjects and those with postpoliomyelitis syndrome: A high-density surface EMG study. Muscle Nerve 2004,30(3):269-276. 10.1002/mus.20104CrossRefPubMed
4.
go back to reference Kleine BU, van Dijk JP, Lapatki BG, Zwarts MJ, Stegeman DF: Using two-dimensional spatial information in decomposition of surface EMG signals. J Electromyogr Kinesiol 2007,17(5):535-548. 10.1016/j.jelekin.2006.05.003CrossRefPubMed Kleine BU, van Dijk JP, Lapatki BG, Zwarts MJ, Stegeman DF: Using two-dimensional spatial information in decomposition of surface EMG signals. J Electromyogr Kinesiol 2007,17(5):535-548. 10.1016/j.jelekin.2006.05.003CrossRefPubMed
5.
go back to reference Zwarts MJ, Stegeman DF: Multichannel surface EMG: Basic aspects and clinical utility. Muscle Nerve 2003,28(1):1-17. 10.1002/mus.10358CrossRefPubMed Zwarts MJ, Stegeman DF: Multichannel surface EMG: Basic aspects and clinical utility. Muscle Nerve 2003,28(1):1-17. 10.1002/mus.10358CrossRefPubMed
6.
go back to reference Holobar A, Minetto MA, Botter A, Negro F, Farina D: Experimental analysis of accuracy in the identification of motor unit spike trains from high-density surface EMG. IEEE Trans Neural Syst Rehabil Eng 2010,18(3):221-229.CrossRefPubMed Holobar A, Minetto MA, Botter A, Negro F, Farina D: Experimental analysis of accuracy in the identification of motor unit spike trains from high-density surface EMG. IEEE Trans Neural Syst Rehabil Eng 2010,18(3):221-229.CrossRefPubMed
7.
go back to reference Merletti R, Holobar A, Farina D: Analysis of motor units with high-density surface electromyography. J Electromyogr Kinesiol 2008,18(6):879-890. 10.1016/j.jelekin.2008.09.002CrossRefPubMed Merletti R, Holobar A, Farina D: Analysis of motor units with high-density surface electromyography. J Electromyogr Kinesiol 2008,18(6):879-890. 10.1016/j.jelekin.2008.09.002CrossRefPubMed
8.
go back to reference Farina D, Lorrain T, Negro F, Jiang N: High-density EMG E-textile systems for the control of active prostheses. Proc IEEE Int Conf Eng Med Biol Soc 2010, 3591-3593. Farina D, Lorrain T, Negro F, Jiang N: High-density EMG E-textile systems for the control of active prostheses. Proc IEEE Int Conf Eng Med Biol Soc 2010, 3591-3593.
9.
go back to reference Vieira TMM, Merletti R, Mesin L: Automatic segmentation of surface EMG images: Improving the estimation of neuromuscular activity. J Biomech 2010,43(11):2149-2158. 10.1016/j.jbiomech.2010.03.049CrossRefPubMed Vieira TMM, Merletti R, Mesin L: Automatic segmentation of surface EMG images: Improving the estimation of neuromuscular activity. J Biomech 2010,43(11):2149-2158. 10.1016/j.jbiomech.2010.03.049CrossRefPubMed
10.
go back to reference Tucker K, Falla D, Graven-Nielsen T, Farina D: Electromyographic mapping of the erector spinae muscle with varying load and during sustained contraction. J Electromyogr Kinesiol 2009,19(3):373-379. 10.1016/j.jelekin.2007.10.003CrossRefPubMed Tucker K, Falla D, Graven-Nielsen T, Farina D: Electromyographic mapping of the erector spinae muscle with varying load and during sustained contraction. J Electromyogr Kinesiol 2009,19(3):373-379. 10.1016/j.jelekin.2007.10.003CrossRefPubMed
11.
go back to reference Holtermann A, Roeleveld K, Karlsson JS: Inhomogeneities in muscle activation reveal motor unit recruitment. J Electromyogr Kinesiol 2005,15(2):131-137. 10.1016/j.jelekin.2004.09.003CrossRefPubMed Holtermann A, Roeleveld K, Karlsson JS: Inhomogeneities in muscle activation reveal motor unit recruitment. J Electromyogr Kinesiol 2005,15(2):131-137. 10.1016/j.jelekin.2004.09.003CrossRefPubMed
12.
go back to reference Staudenmann D, Kingma I, Daffertshofer A, Stegeman DF, van Dieën JH: Heterogeneity of muscle activation in relation to force direction: A multi-channel surface electromyography study on the triceps surae muscle. J Electromyogr Kinesiol 2009,19(5):882-895. 10.1016/j.jelekin.2008.04.013CrossRefPubMed Staudenmann D, Kingma I, Daffertshofer A, Stegeman DF, van Dieën JH: Heterogeneity of muscle activation in relation to force direction: A multi-channel surface electromyography study on the triceps surae muscle. J Electromyogr Kinesiol 2009,19(5):882-895. 10.1016/j.jelekin.2008.04.013CrossRefPubMed
13.
go back to reference Merletti R, Aventaggiato M, Botter A, Holobar A, Marateb H, Vieira TMM: Advances in surface EMG: Recent progress in detection and processing techniques. Crit Rev Biomed Eng 2010,38(4):305-345. 10.1615/CritRevBiomedEng.v38.i4.10CrossRefPubMed Merletti R, Aventaggiato M, Botter A, Holobar A, Marateb H, Vieira TMM: Advances in surface EMG: Recent progress in detection and processing techniques. Crit Rev Biomed Eng 2010,38(4):305-345. 10.1615/CritRevBiomedEng.v38.i4.10CrossRefPubMed
14.
go back to reference Merletti R, Botter A, Cescon C, Minetto MA, Vieira TMM: Advances in surface EMG: Recent progress in clinical research applications. Crit Rev Biomed Eng 2010,38(4):347-379. 10.1615/CritRevBiomedEng.v38.i4.20CrossRefPubMed Merletti R, Botter A, Cescon C, Minetto MA, Vieira TMM: Advances in surface EMG: Recent progress in clinical research applications. Crit Rev Biomed Eng 2010,38(4):347-379. 10.1615/CritRevBiomedEng.v38.i4.20CrossRefPubMed
15.
go back to reference Gronlund C, Roeleveld K, Holtermann A, Karlsson JS: On-line signal quality estimation of multichannel surface electromyograms. Med Biol Eng Comput 2005,43(3):357-364. 10.1007/BF02345813CrossRefPubMed Gronlund C, Roeleveld K, Holtermann A, Karlsson JS: On-line signal quality estimation of multichannel surface electromyograms. Med Biol Eng Comput 2005,43(3):357-364. 10.1007/BF02345813CrossRefPubMed
16.
go back to reference Marateb HR, Rojas-Martinez M, Mansourian M, Merletti R, Mananas Villanueva MA: Outlier detection in high-density surface electromyographic signals. Med Biol Eng Comput 2012,50(1):79-89. 10.1007/s11517-011-0790-7CrossRefPubMed Marateb HR, Rojas-Martinez M, Mansourian M, Merletti R, Mananas Villanueva MA: Outlier detection in high-density surface electromyographic signals. Med Biol Eng Comput 2012,50(1):79-89. 10.1007/s11517-011-0790-7CrossRefPubMed
17.
go back to reference Vincent L: Morphological grayscale reconstruction in image analysis: Applications and efficient algorithms. IEEE Trans Image Process 1993,2(2):176-201. 10.1109/83.217222CrossRefPubMed Vincent L: Morphological grayscale reconstruction in image analysis: Applications and efficient algorithms. IEEE Trans Image Process 1993,2(2):176-201. 10.1109/83.217222CrossRefPubMed
18.
go back to reference Metting Van Rijn A, Peper A, Grimbergen C: High-quality recording of bioelectric events. Med Biol Eng Comput 1990,28(5):389-397. 10.1007/BF02441961CrossRefPubMed Metting Van Rijn A, Peper A, Grimbergen C: High-quality recording of bioelectric events. Med Biol Eng Comput 1990,28(5):389-397. 10.1007/BF02441961CrossRefPubMed
19.
go back to reference Kendall F, McCreary E, Provance P: Muscles: Testing and Function. 4th edition. Baltimore, Md: Williams & Wilkins; 1993. Kendall F, McCreary E, Provance P: Muscles: Testing and Function. 4th edition. Baltimore, Md: Williams & Wilkins; 1993.
20.
go back to reference Freriks B, Hermens HJ: SENIAM9: European Recommendations for Surface ElectroMyoGraphy, Results of the SENIAM Project, ISBN: 90-75452-14-4 (CD-rom). The Netherlands: Roessingh Research and Development; 1999. Freriks B, Hermens HJ: SENIAM9: European Recommendations for Surface ElectroMyoGraphy, Results of the SENIAM Project, ISBN: 90-75452-14-4 (CD-rom). The Netherlands: Roessingh Research and Development; 1999.
21.
go back to reference Clancy EA, Morin EL, Merletti R: Sampling, noise-reduction and amplitude estimation issues in surface electromyography. J Electromyogr Kinesiol 2002,12(1):1-16. 10.1016/S1050-6411(01)00033-5CrossRefPubMed Clancy EA, Morin EL, Merletti R: Sampling, noise-reduction and amplitude estimation issues in surface electromyography. J Electromyogr Kinesiol 2002,12(1):1-16. 10.1016/S1050-6411(01)00033-5CrossRefPubMed
22.
go back to reference Hampel FR: A general qualitative definition of robustness. Ann Math Stat 1971,42(6):1887-1896. 10.1214/aoms/1177693054CrossRef Hampel FR: A general qualitative definition of robustness. Ann Math Stat 1971,42(6):1887-1896. 10.1214/aoms/1177693054CrossRef
23.
go back to reference Farina D, Colombo R, Merletti R, Baare Olsen H: Evaluation of intra-muscular EMG signal decomposition algorithms. J Electromyogr Kinesiol 2001,11(3):175-187. 10.1016/S1050-6411(00)00051-1CrossRefPubMed Farina D, Colombo R, Merletti R, Baare Olsen H: Evaluation of intra-muscular EMG signal decomposition algorithms. J Electromyogr Kinesiol 2001,11(3):175-187. 10.1016/S1050-6411(00)00051-1CrossRefPubMed
24.
go back to reference Fleiss JL: Measuring nominal scale agreement among many raters. Psychol Bull 1971,76(5):378-382.CrossRef Fleiss JL: Measuring nominal scale agreement among many raters. Psychol Bull 1971,76(5):378-382.CrossRef
25.
go back to reference Fawcett T: An introduction to ROC analysis. Pattern Recog Lett. 2006,27(8):861-874. 10.1016/j.patrec.2005.10.010CrossRef Fawcett T: An introduction to ROC analysis. Pattern Recog Lett. 2006,27(8):861-874. 10.1016/j.patrec.2005.10.010CrossRef
26.
go back to reference Landgrebe TC, Paclik P, Duin RP, Bradley AP: Precision-recall operating characteristic (P-ROC) curves in imprecise environments. In Proceedings of 18th International Conference on Pattern Recognition. Los Alamitos, California USA . IEEE Computer Society 2006, 4: 123-127. Landgrebe TC, Paclik P, Duin RP, Bradley AP: Precision-recall operating characteristic (P-ROC) curves in imprecise environments. In Proceedings of 18th International Conference on Pattern Recognition. Los Alamitos, California USA . IEEE Computer Society 2006, 4: 123-127.
27.
go back to reference Hermens H, Freriks B, Disselhorst-Klug C, Rau G: Development of recommendations for sensors and sensor placement procedures. J Electromyogr Kinesiol 2000,10(5):361-374. 10.1016/S1050-6411(00)00027-4CrossRefPubMed Hermens H, Freriks B, Disselhorst-Klug C, Rau G: Development of recommendations for sensors and sensor placement procedures. J Electromyogr Kinesiol 2000,10(5):361-374. 10.1016/S1050-6411(00)00027-4CrossRefPubMed
28.
go back to reference Bradford Barber C, Dobkin DP, Huhdanpaa H: The quickhull algorithm for convex hulls. ACM Trans Math Softw 1996,22(4):469-483. 10.1145/235815.235821CrossRef Bradford Barber C, Dobkin DP, Huhdanpaa H: The quickhull algorithm for convex hulls. ACM Trans Math Softw 1996,22(4):469-483. 10.1145/235815.235821CrossRef
29.
go back to reference Serra J: Image analysis and mathematical morphology. London: Academic; 1982. Serra J: Image analysis and mathematical morphology. London: Academic; 1982.
30.
go back to reference Zar JH: Biostatistical analysis. 5th edition. New Jersey: Prentice Hall; 2010. Zar JH: Biostatistical analysis. 5th edition. New Jersey: Prentice Hall; 2010.
31.
go back to reference Krzanowski WJ: Principles of multivariate analysis: A user's perspective. New York: Oxford University Press; 1988. Krzanowski WJ: Principles of multivariate analysis: A user's perspective. New York: Oxford University Press; 1988.
32.
go back to reference Kearns M, Ron D: Algorithmic stability and sanity-check bounds for leave-one-out cross-validation. Neural Comput 1999,11(6):1427-1453. 10.1162/089976699300016304CrossRefPubMed Kearns M, Ron D: Algorithmic stability and sanity-check bounds for leave-one-out cross-validation. Neural Comput 1999,11(6):1427-1453. 10.1162/089976699300016304CrossRefPubMed
33.
go back to reference Tkach D, Huang H, Kuiken TA: Study of stability of time-domain features for electromyographic pattern recognition. J Neuroeng Rehabil 2010, 7: 21. 10.1186/1743-0003-7-21PubMedCentralCrossRefPubMed Tkach D, Huang H, Kuiken TA: Study of stability of time-domain features for electromyographic pattern recognition. J Neuroeng Rehabil 2010, 7: 21. 10.1186/1743-0003-7-21PubMedCentralCrossRefPubMed
34.
go back to reference Hogan N, Krebs HI, Rohrer B, Palazzolo JJ, Dipietro L, Fasoli SE, et al.: Motions or muscles? some behavioral factors underlying robotic assistance of motor recovery. J Rehabil Res Dev 2006,43(5):605-618. 10.1682/JRRD.2005.06.0103CrossRefPubMed Hogan N, Krebs HI, Rohrer B, Palazzolo JJ, Dipietro L, Fasoli SE, et al.: Motions or muscles? some behavioral factors underlying robotic assistance of motor recovery. J Rehabil Res Dev 2006,43(5):605-618. 10.1682/JRRD.2005.06.0103CrossRefPubMed
Metadata
Title
High-density surface EMG maps from upper-arm and forearm muscles
Authors
Monica Rojas-Martínez
Miguel A Mañanas
Joan F Alonso
Publication date
01-12-2012
Publisher
BioMed Central
Published in
Journal of NeuroEngineering and Rehabilitation / Issue 1/2012
Electronic ISSN: 1743-0003
DOI
https://doi.org/10.1186/1743-0003-9-85

Other articles of this Issue 1/2012

Journal of NeuroEngineering and Rehabilitation 1/2012 Go to the issue