Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2017

Open Access 01-12-2017 | Case report

Hemoglobin Himeji and inconsistent hemoglobin A1c values: a case report

Authors: Vânia Guedes, Rita Bettencourt-Silva, Joana Queirós, Maria da Luz Esteves, Maria José Teles, Davide Carvalho

Published in: Journal of Medical Case Reports | Issue 1/2017

Login to get access

Abstract

Background

Hemoglobin A1c is used to evaluate the glycemic control in patients with diabetes and is a risk marker for chronic complications of diabetes. Hemoglobin variants are reported to falsely lower or increase hemoglobin A1c test results. We present a case report of a patient with diabetes with discrepancy between fasting plasma glucose and hemoglobin A1c due to the presence of hemoglobin Himeji, a clinically silent and very rare hemoglobinopathy.

Case presentation

A 76-year-old white woman, born and living in Portugal, with type 2 diabetes presented to the family physician for a routine visit. She had no active complaints, including history or symptoms of hypoglycemia, and her physical examination was unremarkable. A review of her laboratory data showed fasting plasma glucose of 190 mg/dL and a hemoglobin A1c of 4.1%. The remaining blood test results were clinically insignificant; a further review of her laboratory data over the past 4 years revealed that her fasting plasma glucose had ranged from 130 to 250 mg/dL and hemoglobin A1c was consistently lower than 5%. A study of hemoglobins detected 32.8% of abnormal hemoglobin. Genetic sequencing identified a heterozygous mutation compatible with hemoglobin Himeji (c.422C>A; p.Ala141Asp). We tracked her family (three sons, six grandchildren, and two greatgrandchildren) for the presence of this hemoglobin variant, but none had this hemoglobinopathy.

Conclusions

Despite the advantages of hemoglobin A1c in the follow-up and treatment of diabetes, the factors that interfere with its results must be known to ensure a correct estimation of the degree of glycemic control and a proper management of the disease. Therefore, health professionals should suspect the existence of hemoglobin variants when: the hemoglobin A1c value is above 15% or below the lower limit of its reference interval; there is a significant modification in its result coinciding with a change in assay methods; and there is a low correlation between plasma glucose and hemoglobin A1c. In patients with hemoglobin Himeji, alternate ways of monitoring glycemic control (fructosamine or glycated serum albumin) should be used.
Literature
1.
go back to reference Goldstein DE, Little RR, Lorenz RA, Malone JI, Nathan D, Peterson CM, Sacks DB. Tests of glycemia in diabetes. Diabetes Care. 2004;27:1761–73.CrossRefPubMed Goldstein DE, Little RR, Lorenz RA, Malone JI, Nathan D, Peterson CM, Sacks DB. Tests of glycemia in diabetes. Diabetes Care. 2004;27:1761–73.CrossRefPubMed
2.
go back to reference Sacks DB, Arnold M, Bakris GL, Bruns DE, Horvath AR, Kirkman MS, Lernmark A, Metzger BE, Nathan DM, National Academy of Clinical Biochemistry; Evidence-Based Laboratory Medicine Committee of the American Association for Clinical Chemistry. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care. 2011;34:e61–99.CrossRefPubMedPubMedCentral Sacks DB, Arnold M, Bakris GL, Bruns DE, Horvath AR, Kirkman MS, Lernmark A, Metzger BE, Nathan DM, National Academy of Clinical Biochemistry; Evidence-Based Laboratory Medicine Committee of the American Association for Clinical Chemistry. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care. 2011;34:e61–99.CrossRefPubMedPubMedCentral
3.
go back to reference Nathan DM, Kuenen J, Borg R, Zheng H, Schoenfeld D, Heine RJ, A1c-Derived Average Glucose Study Group. Translating the A1C assay into estimated average glucose values. Diabetes Care. 2008;31:1473–8.CrossRefPubMedPubMedCentral Nathan DM, Kuenen J, Borg R, Zheng H, Schoenfeld D, Heine RJ, A1c-Derived Average Glucose Study Group. Translating the A1C assay into estimated average glucose values. Diabetes Care. 2008;31:1473–8.CrossRefPubMedPubMedCentral
4.
go back to reference American Diabetes Association. Standards of Medical Care in Diabetes – 2017. Diabetes Care. 2017;40 Suppl. 1:S1–S135. American Diabetes Association. Standards of Medical Care in Diabetes – 2017. Diabetes Care. 2017;40 Suppl. 1:S1–S135.
6.
go back to reference World Health Organization. Use of glycated haemoglobin (HbA1c) in the diagnosis of diabetes mellitus. Abbreviated Report of a Who Consultation. Geneva: World Health Organization; 2011. p. 1–25. World Health Organization. Use of glycated haemoglobin (HbA1c) in the diagnosis of diabetes mellitus. Abbreviated Report of a Who Consultation. Geneva: World Health Organization; 2011. p. 1–25.
7.
go back to reference Bry L, Chen PC, Sacks DB. Effects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin. Clin Chem. 2001;47:153–63.PubMed Bry L, Chen PC, Sacks DB. Effects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin. Clin Chem. 2001;47:153–63.PubMed
8.
go back to reference Smaldone A. Glycemic Control and Hemoglobinopathy: When A1C May Not Be Reliable. Diabetes Spectrum. 2008;21:46–9.CrossRef Smaldone A. Glycemic Control and Hemoglobinopathy: When A1C May Not Be Reliable. Diabetes Spectrum. 2008;21:46–9.CrossRef
10.
go back to reference Nishihara E, Koga M, Kadowaki S, Murakami M, Harano K, Ito M, Kubota S, Amino N, Miyauchi A. Method-dependent HbA1c values in a family with hemoglobin Himeji. Clin Chim Acta. 2011;412:1689–92.CrossRefPubMed Nishihara E, Koga M, Kadowaki S, Murakami M, Harano K, Ito M, Kubota S, Amino N, Miyauchi A. Method-dependent HbA1c values in a family with hemoglobin Himeji. Clin Chim Acta. 2011;412:1689–92.CrossRefPubMed
11.
go back to reference Ohba Y, Miyaji T, Murakami M, Kadowaki S, Fujita T, Oimomi M, Hatanaka H, Ishikawa K, Baba S, Hitaka K. Hb Himeji or beta 140 (H18) Ala----Asp. A slightly unstable hemoglobin with increased beta N-terminal glycation. Hemoglobin. 1986;10:109–25.CrossRefPubMed Ohba Y, Miyaji T, Murakami M, Kadowaki S, Fujita T, Oimomi M, Hatanaka H, Ishikawa K, Baba S, Hitaka K. Hb Himeji or beta 140 (H18) Ala----Asp. A slightly unstable hemoglobin with increased beta N-terminal glycation. Hemoglobin. 1986;10:109–25.CrossRefPubMed
12.
go back to reference Lavinha J, Faustino P, Osório-Almeida L, Hattori Y, Ohba Y, Martins MC. Hb Himeji [alpha 2 beta 2(140)(H18)Ala----Asp] is linked to different haplotypes in Japanese and Portuguese families. Hemoglobin. 1991;15:137–8.CrossRefPubMed Lavinha J, Faustino P, Osório-Almeida L, Hattori Y, Ohba Y, Martins MC. Hb Himeji [alpha 2 beta 2(140)(H18)Ala----Asp] is linked to different haplotypes in Japanese and Portuguese families. Hemoglobin. 1991;15:137–8.CrossRefPubMed
13.
go back to reference Martins MC, Rosado L, Wilson JB, Kutlar A, Hu H, Huisman TH. Hb Himeji or alpha 2 beta 2(140)(H18)Ala----Asp in a Portuguese family. Hemoglobin. 1989;13:411–5.CrossRefPubMed Martins MC, Rosado L, Wilson JB, Kutlar A, Hu H, Huisman TH. Hb Himeji or alpha 2 beta 2(140)(H18)Ala----Asp in a Portuguese family. Hemoglobin. 1989;13:411–5.CrossRefPubMed
14.
go back to reference Speeckaert M, Van Biesen W, Delanghe J, Slingerland R, Wiecek A, Heaf J, Drechsler C, Lacatus R, Vanholder R, Nistor I, European Renal Best Practice Guideline Development Group on Diabetes in Advanced CKD. Are there better alternatives than haemoglobin A1c to estimate glycaemic control in the chronic kidney disease population? Nephrol Dial Transplant. 2014;29:2167–77.CrossRefPubMed Speeckaert M, Van Biesen W, Delanghe J, Slingerland R, Wiecek A, Heaf J, Drechsler C, Lacatus R, Vanholder R, Nistor I, European Renal Best Practice Guideline Development Group on Diabetes in Advanced CKD. Are there better alternatives than haemoglobin A1c to estimate glycaemic control in the chronic kidney disease population? Nephrol Dial Transplant. 2014;29:2167–77.CrossRefPubMed
15.
go back to reference Barcellini W, Fattizzo B. Clinical Applications of Hemolytic Markers in the Differential Diagnosis and Management of Hemolytic Anemia. Dis Markers. 2015;2015:635670.CrossRefPubMedPubMedCentral Barcellini W, Fattizzo B. Clinical Applications of Hemolytic Markers in the Differential Diagnosis and Management of Hemolytic Anemia. Dis Markers. 2015;2015:635670.CrossRefPubMedPubMedCentral
16.
go back to reference Hayes AJ, Leal J, Gray AM, Holman RR, Clarke PM. UKPDS outcomes model 2: a new version of a model to simulate lifetime health outcomes of patients with type 2 diabetes mellitus using data from the 30 year United Kingdom Prospective Diabetes Study: UKPDS 82. Diabetologia. 2013;56:1925–33.CrossRefPubMed Hayes AJ, Leal J, Gray AM, Holman RR, Clarke PM. UKPDS outcomes model 2: a new version of a model to simulate lifetime health outcomes of patients with type 2 diabetes mellitus using data from the 30 year United Kingdom Prospective Diabetes Study: UKPDS 82. Diabetologia. 2013;56:1925–33.CrossRefPubMed
Metadata
Title
Hemoglobin Himeji and inconsistent hemoglobin A1c values: a case report
Authors
Vânia Guedes
Rita Bettencourt-Silva
Joana Queirós
Maria da Luz Esteves
Maria José Teles
Davide Carvalho
Publication date
01-12-2017
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2017
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-017-1377-1

Other articles of this Issue 1/2017

Journal of Medical Case Reports 1/2017 Go to the issue