Skip to main content
Top
Published in: Journal of Artificial Organs 1/2016

01-03-2016 | Original Article

Hemodynamics of a functional centrifugal-flow total artificial heart with functional atrial contraction in goats

Authors: Takuya Shiga, Yasuyuki Shiraishi, Kyosuke Sano, Yasunori Taira, Yusuke Tsuboko, Akihiro Yamada, Hidekazu Miura, Shintaro Katahira, Masatoshi Akiyama, Yoshikatsu Saiki, Tomoyuki Yambe

Published in: Journal of Artificial Organs | Issue 1/2016

Login to get access

Abstract

Implantation of a total artificial heart (TAH) is one of the therapeutic options for the treatment of patients with end-stage biventricular heart failure. There is no report on the hemodynamics of the functional centrifugal-flow TAH with functional atrial contraction (fCFTAH). We evaluated the effects of pulsatile flow by atrial contraction in acute animal models. The goats received fCFTAH that we created from two centrifugal-flow ventricular assist devices. Some hemodynamic parameters maintained acceptable levels: heart rate 115.5 ± 26.3 bpm, aortic pressure 83.5 ± 10.1 mmHg, left atrial pressure 18.0 ± 5.9 mmHg, pulmonary pressure 28.5 ± 9.7 mmHg, right atrial pressure 13.6 ± 5.2 mmHg, pump flow 4.0 ± 1.1 L/min (left) 3.9 ± 1.1 L/min (right), and cardiac index 2.13 ± 0.14 L/min/m2. fCFTAH with atrial contraction was able to maintain the TAH circulation by forming a pulsatile flow in acute animal experiments. Taking the left and right flow rate balance using the low internal pressure loss of the VAD pumps may be easier than by other pumps having considerable internal pressure loss. We showed that the remnant atrial contraction effected the flow rate change of the centrifugal pump, and the atrial contraction waves reflected the heart rate. These results indicate that remnant atria had the possibility to preserve autonomic function in fCFTAH. We may control fCFTAH by reflecting the autonomic function, which is estimated with the flow rate change of the centrifugal pump.
Literature
1.
go back to reference Roger VL, Go AS, Lloyd-Jones DM, Adams RJ, Berry JD, Brown TM, Carnethon MR, Dai S, de Simone G, Ford ES, Fox CS, Fullerton HJ, Gillespie C, Greenlund KJ, Hailpern SM, Heit JA, Ho PM, Howard VJ, Kissela BM, Kittner SJ, Lackland DT, Lichtman JH, Lisabeth LD, Makuc DM, Marcus GM, Marelli A, Matchar DB, McDermott MM, Meigs JB, Moy CS, Mozaffarian D, Mussolino ME, Nichol G, Paynter NP, Rosamond WD, Sorlie PD, Stafford RS, Turan TN, Turner MB, Wong ND, Wylie-Rosett J. Heart disease and stroke statistics—2011 update: a report from the American Heart Association. Circulation. 2010;123:e18–209.CrossRefPubMedPubMedCentral Roger VL, Go AS, Lloyd-Jones DM, Adams RJ, Berry JD, Brown TM, Carnethon MR, Dai S, de Simone G, Ford ES, Fox CS, Fullerton HJ, Gillespie C, Greenlund KJ, Hailpern SM, Heit JA, Ho PM, Howard VJ, Kissela BM, Kittner SJ, Lackland DT, Lichtman JH, Lisabeth LD, Makuc DM, Marcus GM, Marelli A, Matchar DB, McDermott MM, Meigs JB, Moy CS, Mozaffarian D, Mussolino ME, Nichol G, Paynter NP, Rosamond WD, Sorlie PD, Stafford RS, Turan TN, Turner MB, Wong ND, Wylie-Rosett J. Heart disease and stroke statistics—2011 update: a report from the American Heart Association. Circulation. 2010;123:e18–209.CrossRefPubMedPubMedCentral
2.
go back to reference Mehra MR, Kobashigawa J, Starling R, Russell S, Uber PA, Parameshwar J, Mohacsi P, Augustine S, Aaronson K, Barr M. Listing criteria for heart transplantation: International Society for Heart and Lung Transplantation guidelines for the care of cardiac transplant candidates—2006. J Heart Lung Transplant. 2006;25:1024–42.CrossRefPubMed Mehra MR, Kobashigawa J, Starling R, Russell S, Uber PA, Parameshwar J, Mohacsi P, Augustine S, Aaronson K, Barr M. Listing criteria for heart transplantation: International Society for Heart and Lung Transplantation guidelines for the care of cardiac transplant candidates—2006. J Heart Lung Transplant. 2006;25:1024–42.CrossRefPubMed
3.
go back to reference Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, Long JW, Ascheim DD, Tierney AR, Levitan RG, Watson JT, Meier P, Ronan NS, Shapiro PA, Lazar RM, Miller LW, Gupta L, Frazier OH, Desvigne-Nickens P, Oz MC, Poirier VL. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 2001;345:1435–43.CrossRefPubMed Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, Long JW, Ascheim DD, Tierney AR, Levitan RG, Watson JT, Meier P, Ronan NS, Shapiro PA, Lazar RM, Miller LW, Gupta L, Frazier OH, Desvigne-Nickens P, Oz MC, Poirier VL. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 2001;345:1435–43.CrossRefPubMed
4.
go back to reference Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Stevenson L, Miller M, and Young JB, Long-term mechanical circulatory support (destination therapy): on track to compete with heart transplantation? J Thorac Cardiovasc Surg. 2012;144:584–603; discussion 597-8. Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Stevenson L, Miller M, and Young JB, Long-term mechanical circulatory support (destination therapy): on track to compete with heart transplantation? J Thorac Cardiovasc Surg. 2012;144:584–603; discussion 597-8.
5.
go back to reference Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Stevenson LW, Blume ED, Miller MA, Timothy Baldwin J, Young JB. Sixth INTERMACS annual report: a 10,000-patient database. J Heart Lung Transplant. 2014;33:555–64.CrossRefPubMed Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Stevenson LW, Blume ED, Miller MA, Timothy Baldwin J, Young JB. Sixth INTERMACS annual report: a 10,000-patient database. J Heart Lung Transplant. 2014;33:555–64.CrossRefPubMed
6.
go back to reference Friedline K, Hassinger P. Total artificial heart freedom driver in a patient with end-stage biventricular heart failure. AANA J. 2012;80:105–12.PubMed Friedline K, Hassinger P. Total artificial heart freedom driver in a patient with end-stage biventricular heart failure. AANA J. 2012;80:105–12.PubMed
7.
go back to reference Terracciano CM, Miller LW, Yacoub MH. Contemporary use of ventricular assist devices. Annu Rev Med. 2010;61:255–70.CrossRefPubMed Terracciano CM, Miller LW, Yacoub MH. Contemporary use of ventricular assist devices. Annu Rev Med. 2010;61:255–70.CrossRefPubMed
8.
go back to reference Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM III, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361:2241–51.CrossRefPubMed Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM III, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361:2241–51.CrossRefPubMed
9.
go back to reference Frazier OH, Cohn WE, Tuzun E, Winkler JA, Gregoric ID. Continuous-flow total artificial heart supports long-term survival of a calf. Tex Heart Inst J. 2009;36:568–74.PubMedPubMedCentral Frazier OH, Cohn WE, Tuzun E, Winkler JA, Gregoric ID. Continuous-flow total artificial heart supports long-term survival of a calf. Tex Heart Inst J. 2009;36:568–74.PubMedPubMedCentral
10.
go back to reference Moazami N, Fukamachi K, Kobayashi M, Smedira NG, Hoercher KJ, Massiello A, Lee S, Horvath DJ, Starling RC. Axial and centrifugal continuous-flow rotary pumps: a translation from pump mechanics to clinical practice. J Heart Lung Transplant. 2013;32:1–11.CrossRefPubMed Moazami N, Fukamachi K, Kobayashi M, Smedira NG, Hoercher KJ, Massiello A, Lee S, Horvath DJ, Starling RC. Axial and centrifugal continuous-flow rotary pumps: a translation from pump mechanics to clinical practice. J Heart Lung Transplant. 2013;32:1–11.CrossRefPubMed
11.
go back to reference Shiga T, Kuroda T, Tsuboko Y, Miura H, Shiraishi Y, Yambe T. Hemodynamic effects of pressure–volume relation in the atrial contraction model on the total artificial heart using centrifugal blood pumps. Conf Proc IEEE Eng Med Biol Soc. 2013;2013:1815–8.PubMed Shiga T, Kuroda T, Tsuboko Y, Miura H, Shiraishi Y, Yambe T. Hemodynamic effects of pressure–volume relation in the atrial contraction model on the total artificial heart using centrifugal blood pumps. Conf Proc IEEE Eng Med Biol Soc. 2013;2013:1815–8.PubMed
12.
go back to reference Murray KD, Binkley PF, Watson KM, Howanitz EP, Ross P Jr, Myerowitz PD. Remnant atrial function in human and animal recipients of a total artificial heart. J Heart Lung Transplant. 1992;11:1066–72.PubMed Murray KD, Binkley PF, Watson KM, Howanitz EP, Ross P Jr, Myerowitz PD. Remnant atrial function in human and animal recipients of a total artificial heart. J Heart Lung Transplant. 1992;11:1066–72.PubMed
13.
go back to reference Sato M, Tasaki I, Annaka A. Studies on the metabolism of dairy goat. III Deciding the formula for calculating the body surface aria. Nihon Chikusan Gakkaiho. 1954;25:25–9.CrossRef Sato M, Tasaki I, Annaka A. Studies on the metabolism of dairy goat. III Deciding the formula for calculating the body surface aria. Nihon Chikusan Gakkaiho. 1954;25:25–9.CrossRef
14.
go back to reference Kobayashi M, Horvath DJ, Mielke N, Shiose A, Kuban B, Goodin M, Fukamachi K, Golding LA. Progress on the design and development of the continuous-flow total artificial heart. Artif Organs. 2012;36:705–13.CrossRefPubMedPubMedCentral Kobayashi M, Horvath DJ, Mielke N, Shiose A, Kuban B, Goodin M, Fukamachi K, Golding LA. Progress on the design and development of the continuous-flow total artificial heart. Artif Organs. 2012;36:705–13.CrossRefPubMedPubMedCentral
15.
go back to reference Timms D, Fraser J, Hayne M, Dunning J, McNeil K, Pearcy M. The BiVACOR rotary biventricular assist device: concept and in vitro investigation. Artif Organs. 2008;32:816–9.CrossRefPubMed Timms D, Fraser J, Hayne M, Dunning J, McNeil K, Pearcy M. The BiVACOR rotary biventricular assist device: concept and in vitro investigation. Artif Organs. 2008;32:816–9.CrossRefPubMed
16.
go back to reference Tanaka A, Yoshizawa M, Abe K, Takeda H, Yambe T, Nitta S, Abe Y, Chinzei T, Imachi K. Open-loop analysis of transfer characteristics from blood pressure to heart rate using an effectively total artificial heart. Artif Organs. 2004;28:109–14.CrossRefPubMed Tanaka A, Yoshizawa M, Abe K, Takeda H, Yambe T, Nitta S, Abe Y, Chinzei T, Imachi K. Open-loop analysis of transfer characteristics from blood pressure to heart rate using an effectively total artificial heart. Artif Organs. 2004;28:109–14.CrossRefPubMed
17.
go back to reference Abe Y, Ishii K, Isoyama T, Saito I, Inoue Y, Ono T, Nakagawa H, Nakano E, Fukazawa K, Ishihara K, Fukunaga K, Ono M, Imachi K. The helical flow pump with a hydrodynamic levitation impeller. J Artif Organs. 2012;15:331–40.CrossRefPubMed Abe Y, Ishii K, Isoyama T, Saito I, Inoue Y, Ono T, Nakagawa H, Nakano E, Fukazawa K, Ishihara K, Fukunaga K, Ono M, Imachi K. The helical flow pump with a hydrodynamic levitation impeller. J Artif Organs. 2012;15:331–40.CrossRefPubMed
Metadata
Title
Hemodynamics of a functional centrifugal-flow total artificial heart with functional atrial contraction in goats
Authors
Takuya Shiga
Yasuyuki Shiraishi
Kyosuke Sano
Yasunori Taira
Yusuke Tsuboko
Akihiro Yamada
Hidekazu Miura
Shintaro Katahira
Masatoshi Akiyama
Yoshikatsu Saiki
Tomoyuki Yambe
Publication date
01-03-2016
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 1/2016
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-015-0852-y

Other articles of this Issue 1/2016

Journal of Artificial Organs 1/2016 Go to the issue