Heat and mass transfer from a baby manikin: impact of a chemical warfare protective bag

Author: Ulf Danielsson

Published in: European Journal of Applied Physiology | Issue 6/2004

Login to get access

Abstract

A chemical warfare (CW) protective bag for babies, younger than 1 year, has been evaluated in respect of thermal load. Heat and water vapour dissipating from the baby make the climate in the protective bag more demanding than outside. The thermal strain on a baby was estimated from heat and mass transfer data using an electrically heated baby manikin and a water-filled tray. Furthermore, a theoretical baby model was developed based on relations valid for heat and mass transfer rates from a cylinder and flat surface. Convective and radiative (dry) and evaporative heat transfer coefficients calculated from this model agreed well with the measured values. The maximum heat dissipation from a baby was calculated for combinations of air temperatures (22–30°C) and relative humidities (70–90% rh). The results indicate that a naked baby can dissipate about 100% more heat than is produced during basal conditions when the bag is ventilated (70 l min−1) and the ambient climate is 30°C and 90% rh. If the ventilation rate is 40 l min−1, the margin is reduced to 50%. Clothing reduces the margin further. Ventilating the bag with 70 l min−1, a dressed baby can dissipate only 10–20% more heat than is produced during basal conditions in a climate (27°C and 80% rh) that is obtained in a crowded shelter after about 24 h of occupation.
Literature
go back to reference Kakitsuba N, Bondi KR (1987) Heat transfer from human body in hyperthermic, low gas-velocity environments. Aviat Space Environ Med 58:227–236PubMed Kakitsuba N, Bondi KR (1987) Heat transfer from human body in hyperthermic, low gas-velocity environments. Aviat Space Environ Med 58:227–236PubMed
go back to reference McLean JA, Tobin G (1987) Animal and human calorimetry. Cambridge University Press, Cambridge, UK McLean JA, Tobin G (1987) Animal and human calorimetry. Cambridge University Press, Cambridge, UK
go back to reference Wheldon A E (1982) Energy balance in a newborn baby: use of a manikin to estimate radiant and convective heat loss. Phys Med Biol 27:285–296CrossRefPubMed Wheldon A E (1982) Energy balance in a newborn baby: use of a manikin to estimate radiant and convective heat loss. Phys Med Biol 27:285–296CrossRefPubMed
Metadata
Title
Heat and mass transfer from a baby manikin: impact of a chemical warfare protective bag
Author
Ulf Danielsson
Publication date
01-09-2004
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 6/2004
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-004-1133-2

Other articles of this Issue 6/2004

European Journal of Applied Physiology 6/2004 Go to the issue

EditorialNotes

Editorial