01-04-2021 | Heart Surgery | Original Article
Use of a cutting stapler to excise a left atrial appendage in minimally invasive cardiac surgery
Published in: Surgery Today | Issue 4/2021
Login to get accessAbstract
Purpose
A cutting stapler is a well-established instrument in many surgical fields. However, its efficacy and safety have not been proven yet in resecting a left atrial appendage (LAA) in minimally invasive cardiac surgery (MICS).
Methods
A cutting stapler was used to resect the LAA in 98 consecutive patients who underwent MICS. Of these, 26 patients underwent aortic valve replacement, 72 mitral valve repair/replacement, 25 tricuspid annuloplasty, 7 closure of atrial septal defect, and 26 the Maze procedure (contains overlapping). The ascending aorta was elevated using a retractor, and a 12-mm shaft motor-driven cutting stapler was inserted through the transverse sinus. As a control group, 150 patients who underwent suture resection/closure of the LAA either from inside or outside were compared.
Results
There was one mortality in each group. They were not related to the LAA resection/closure. In the suture group, the LAA suture was taken down in one patient because of a suspected obstruction of the circumflex artery, and two patients had re-exploration for bleeding from the LAA. In the stapler group, there was no complication related with the LAA. The rate of complication did not reach a statistical difference.
Conclusion
A cutting stapler is considered to be a useful instrument to resect the LAA in MICS.