Skip to main content
Top
Published in: Surgical Endoscopy 1/2007

01-01-2007 | Original Article

Handheld gamma probe used to detect accessory spleens during initial laparoscopic splenectomies

Authors: Umut Barbaros, Ahmet Dinççağ, Yesim Erbil, Selcuk Mercan, Yasemin Sanli, Işık Adalet, Reyhan Küçükkaya

Published in: Surgical Endoscopy | Issue 1/2007

Login to get access

Abstract

Background

Preoperative determination of the accessory spleen still is a major factor in the failure of both laparoscopic and conventional techniques. This study aimed to evaluate the practicability and efficacy of a handheld gamma probe in identifying accessory spleens at the initial intervention.

Methods

This study evaluated 17 patients undergoing laparoscopic splenectomy attributable to benign hematologic disorders. All the patients had preoperative ultrasonography, computed tomography (CT) scan, and nuclear scintigraphic examination of the abdominal cavity to assess the size of the spleen, and to determine the existence of the accessory spleen or spleens. For all the patients, a handheld gamma probe count was used intraoperatively as an adjuvant method to define the presence and location of the accessory splenic tissue. Control nuclear scintigraphic examinations of all the patients were performed 1 month after the surgical procedure.

Results

In two cases, intraoperatively accessory splenic tissue was detected by gamma probe, confirming the preoperative CT findings for the patients. One of these patients had three accessory spleens, although preoperative CT scan showed only two of them. However, by the help of the gamma probe, a third spleen located retroperitoneally was defined. For two patients, laparoscopic exploration and handheld gamma probe count did not identify any accessory splenic tissue, although preoperative CT scan indicated accessory spleens. For detecting accessory splenic tissue, the sensitivities of the studied techniques were 0% for ultrasonography, 75% for CT scan, 0% for preoperative nuclear scintigraphy, 75% for laparoscopic exploration, and 100% for perioperative gamma probe examination.

Conclusion

Preoperative imaging methods for accessory spleen determination still have limited benefits because of their limited sensitivity. Thus, the handheld gamma probe technique may be an adjuvant method for laparoscopic exploration ensuring that no accessory splenic tissue is missed during the initial surgical treatment of benign hematologic disorders.
Literature
1.
go back to reference Akwari OE, Itani KM, Coleman RE, Rosse WF (1987) Splenectomy for primary and recurrent immune thrombocytopenic purpura (ITP): current criteria for patient selection and results. Ann Surg 206: 529–541PubMedCrossRef Akwari OE, Itani KM, Coleman RE, Rosse WF (1987) Splenectomy for primary and recurrent immune thrombocytopenic purpura (ITP): current criteria for patient selection and results. Ann Surg 206: 529–541PubMedCrossRef
2.
go back to reference Antevil J, Thoman D, Taller J, Biondi M (2002) Laparoscopic accessory splenectomy with intraoperative gamma probe localization for recurrent idiopathic thrombocytopenic purpura. Surg Laparosc Endosc Percutan Tech 12: 371–374PubMedCrossRef Antevil J, Thoman D, Taller J, Biondi M (2002) Laparoscopic accessory splenectomy with intraoperative gamma probe localization for recurrent idiopathic thrombocytopenic purpura. Surg Laparosc Endosc Percutan Tech 12: 371–374PubMedCrossRef
3.
go back to reference Balague C, Targarona EM, Cerdan G, Novell J, Montero O, Bendahan G, Garcia A, Pey A, Vela S, Diaz M, Trias M (2004) Long-term outcome after laparoscopic splenectomy related to hematologic diagnosis. Surg Endosc 18: 1283–1287PubMedCrossRef Balague C, Targarona EM, Cerdan G, Novell J, Montero O, Bendahan G, Garcia A, Pey A, Vela S, Diaz M, Trias M (2004) Long-term outcome after laparoscopic splenectomy related to hematologic diagnosis. Surg Endosc 18: 1283–1287PubMedCrossRef
4.
go back to reference Chowbey PK, Goel A, Panse R, Sharma A, Khullar R, Soni V, Baijal M (2005) Laparoscopic splenectomy for hematologic disorders: experience with the first fifty patients. J Laparoendosc Adv Surg Tech A 15: 28–32PubMedCrossRef Chowbey PK, Goel A, Panse R, Sharma A, Khullar R, Soni V, Baijal M (2005) Laparoscopic splenectomy for hematologic disorders: experience with the first fifty patients. J Laparoendosc Adv Surg Tech A 15: 28–32PubMedCrossRef
5.
go back to reference Chung CW, Lee WJ, Choi JS, Ko YW, Han JS, Min YH, Kim BR (1999) Laparoscopic splenectomy for immune thrombocytopenic purpura: long-term result of 40 laparoscopic splenectomies. Yonsei Med J 40: 578–582PubMed Chung CW, Lee WJ, Choi JS, Ko YW, Han JS, Min YH, Kim BR (1999) Laparoscopic splenectomy for immune thrombocytopenic purpura: long-term result of 40 laparoscopic splenectomies. Yonsei Med J 40: 578–582PubMed
6.
go back to reference Delaitre B, Maignien B (1991) Splenectomy by the laparoscopic approach: report of a case. Presse Med 20: 2263PubMed Delaitre B, Maignien B (1991) Splenectomy by the laparoscopic approach: report of a case. Presse Med 20: 2263PubMed
7.
go back to reference Finkelde DT, Hicks RJ, Wolf M, Henderson MA (2000) Handheld gamma probe localization of accessory splenic tissue in recurrent idiopathic thrombocytopenic purpura. Arch Surg 135: 1112–1113PubMedCrossRef Finkelde DT, Hicks RJ, Wolf M, Henderson MA (2000) Handheld gamma probe localization of accessory splenic tissue in recurrent idiopathic thrombocytopenic purpura. Arch Surg 135: 1112–1113PubMedCrossRef
8.
go back to reference Gigot JF, Jamar F, Ferrant A, van Beers BE, Lengele B, Pauwels S, Pringot J,Kestens PJ, Gianello P, Detry R (1998) Inadequate detection of accessory spleens and splenosis with laparoscopic<splenectomy: a shortcoming of the laparoscopic approach in hematologic diseases. Surg Endosc 12: 101–106PubMedCrossRef Gigot JF, Jamar F, Ferrant A, van Beers BE, Lengele B, Pauwels S, Pringot J,Kestens PJ, Gianello P, Detry R (1998) Inadequate detection of accessory spleens and splenosis with laparoscopic<splenectomy: a shortcoming of the laparoscopic approach in hematologic diseases. Surg Endosc 12: 101–106PubMedCrossRef
9.
go back to reference Mercan S, Seven R, Erbil Y (1996) Laparoscopic treatment of accessory splenic tissue. Surg Laparosc Endosc 6: 330–331PubMedCrossRef Mercan S, Seven R, Erbil Y (1996) Laparoscopic treatment of accessory splenic tissue. Surg Laparosc Endosc 6: 330–331PubMedCrossRef
10.
go back to reference Meyer G, Wichmann MW, Rau HG, Hiller E, Schildberg FW (1998) Laparoscopic splenectomy for idiopathic thrombocytopenic purpura: a 1-year follow-up study. Surg Endosc 12: 1348–1352PubMedCrossRef Meyer G, Wichmann MW, Rau HG, Hiller E, Schildberg FW (1998) Laparoscopic splenectomy for idiopathic thrombocytopenic purpura: a 1-year follow-up study. Surg Endosc 12: 1348–1352PubMedCrossRef
11.
go back to reference Napoli A, Catalano C, Silecchia G, Fabiano P, Fraioli F, Pediconi F, Venditti F, Basso N, Passariello R (2004) Laparoscopic splenectomy: multi-detector row CT for preoperative evaluation. Radiology 232: 361–367PubMed Napoli A, Catalano C, Silecchia G, Fabiano P, Fraioli F, Pediconi F, Venditti F, Basso N, Passariello R (2004) Laparoscopic splenectomy: multi-detector row CT for preoperative evaluation. Radiology 232: 361–367PubMed
12.
go back to reference Park A, Targarona EM, Trias M (2001) Laparoscopic surgery of the spleen: state of the art (review). Langenbecks Arch Surg 386: 230–239PubMedCrossRef Park A, Targarona EM, Trias M (2001) Laparoscopic surgery of the spleen: state of the art (review). Langenbecks Arch Surg 386: 230–239PubMedCrossRef
13.
go back to reference Pohlson EC, Wilkinson RW, Witzum KF, Coel MN (1994) Heat-damaged red cell scan for intraoperative localization of the accessory spleen. J Pediatr Surg 29: 604–608PubMedCrossRef Pohlson EC, Wilkinson RW, Witzum KF, Coel MN (1994) Heat-damaged red cell scan for intraoperative localization of the accessory spleen. J Pediatr Surg 29: 604–608PubMedCrossRef
14.
go back to reference Rogers J, Yousuf A, Kleinhaus S (1997) Laparoscopic accessory splenectomy in recurrent chronic immune thrombocytopenic purpura. Surg Laparosc Endosc 7: 83–85PubMedCrossRef Rogers J, Yousuf A, Kleinhaus S (1997) Laparoscopic accessory splenectomy in recurrent chronic immune thrombocytopenic purpura. Surg Laparosc Endosc 7: 83–85PubMedCrossRef
15.
go back to reference Rudowski WJ (1985) Accessory spleens: clinical significance with particular reference to the recurrence of idiopathic thrombocytopenic purpura. World J Surg 9: 422–430PubMedCrossRef Rudowski WJ (1985) Accessory spleens: clinical significance with particular reference to the recurrence of idiopathic thrombocytopenic purpura. World J Surg 9: 422–430PubMedCrossRef
16.
go back to reference Wu JM, Lai IR, Yuan RH, Yu SC (2004) Laparoscopic splenectomy for idiopathic thrombocytopenic purpura. Am J Surg 187: 720–723PubMedCrossRef Wu JM, Lai IR, Yuan RH, Yu SC (2004) Laparoscopic splenectomy for idiopathic thrombocytopenic purpura. Am J Surg 187: 720–723PubMedCrossRef
Metadata
Title
Handheld gamma probe used to detect accessory spleens during initial laparoscopic splenectomies
Authors
Umut Barbaros
Ahmet Dinççağ
Yesim Erbil
Selcuk Mercan
Yasemin Sanli
Işık Adalet
Reyhan Küçükkaya
Publication date
01-01-2007
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 1/2007
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-006-0001-z

Other articles of this Issue 1/2007

Surgical Endoscopy 1/2007 Go to the issue