Skip to main content
Top
Published in: BMC Ophthalmology 1/2019

Open Access 01-12-2019 | Glaucoma | Research article

Efficacy and safety of Ex-PRESS® mini shunt surgery versus trabeculectomy for neovascular glaucoma: a retrospective comparative study

Authors: Kazuyuki Kawabata, Kohei Shobayashi, Keiichiro Iwao, Eri Takahashi, Hidenobu Tanihara, Toshihiro Inoue

Published in: BMC Ophthalmology | Issue 1/2019

Login to get access

Abstract

Background

The objective of this study is to evaluate and compare the short-term efficacy and safety of Ex-PRESS® mini shunt surgery and trabeculectomy for neovascular glaucoma (NVG).

Methods

Patients with NVG who underwent Ex-PRESS® mini shunt surgery or trabeculectomy as a primary glaucoma surgery between March 2013 and October 2015 were included in the study, and their medical charts were retrospectively reviewed. The Ex-PRESS® and trabeculectomy groups included 14 eyes and 30 eyes, respectively. Surgical failure was defined by an intraocular pressure (IOP) of ≥21 mmHg (condition A) or ≥ 18 mmHg (condition B); Kaplan–Meier survival analyses and the multivariable Cox proportional hazards model were used to assess efficacies.

Results

Kaplan–Meier survival analyses indicated that the probabilities of success at 1 year for the Ex-PRESS® group were 25.7 and 31.8% based on complete and qualified success under condition A, respectively. The corresponding values for the trabeculectomy group were 47.8 and 69.3%, and there was a significant difference in qualified success with condition A (Fig. 1; P = 0.018), while there were no significant differences in the other criteria. Ex-PRESS® mini shunt surgery and higher intraocular pressure were independent prognostic factors using Cox proportional hazards model analyses in qualified success as in condition A (P = 0.012 and 0.0495, respectively). The occurrences of postsurgical hyphema and bleb leaks were significantly higher in the trabeculectomy group (P = 0.005 and 0.008, respectively).

Conclusion

During a 1 year follow-up, Ex-PRESS® mini shunt surgery was a less effective, but safer treatment for NVG compared with trabeculectomy.
Literature
1.
go back to reference Ramulu PY, Corcoran KJ, Corcoran SL, Robin AL. Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995 to 2004. Ophthalmology. 2007;114:2265–70.CrossRef Ramulu PY, Corcoran KJ, Corcoran SL, Robin AL. Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995 to 2004. Ophthalmology. 2007;114:2265–70.CrossRef
2.
go back to reference Vinod K, Gedde SJ, Feuer WJ, Panarelli JF, Chang TC, Chen PP, Parrish RK 2nd. Practice preferences for glaucoma surgery: a survey of the American Glaucoma Society. J Glaucoma 2017;26:687–693. Vinod K, Gedde SJ, Feuer WJ, Panarelli JF, Chang TC, Chen PP, Parrish RK 2nd. Practice preferences for glaucoma surgery: a survey of the American Glaucoma Society. J Glaucoma 2017;26:687–693.
3.
go back to reference de Jong LA. The ex-PRESS glaucoma shunt versus trabeculectomy in open-angle glaucoma: a prospective randomized study. Adv Ther. 2009;26:336–45.CrossRef de Jong LA. The ex-PRESS glaucoma shunt versus trabeculectomy in open-angle glaucoma: a prospective randomized study. Adv Ther. 2009;26:336–45.CrossRef
4.
go back to reference de Jong L, Lafuma A, Aguadé AS, Berdeaux G. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma. Clin Ophthalmol. 2011;5:527–33.PubMedCentral de Jong L, Lafuma A, Aguadé AS, Berdeaux G. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma. Clin Ophthalmol. 2011;5:527–33.PubMedCentral
5.
go back to reference Dahan E, Ben Simon GJ, Lafuma A. Comparison of trabeculectomy and ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised study. Eye. 2012;26:703–10.CrossRef Dahan E, Ben Simon GJ, Lafuma A. Comparison of trabeculectomy and ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised study. Eye. 2012;26:703–10.CrossRef
6.
go back to reference Wagschal LD, Trope GE, Jinapriya D, Jin YP, Buys YM. Prospective randomized study comparing ex-PRESS to trabeculectomy: 1-year results. J Glaucoma. 2015;24:624–9.CrossRef Wagschal LD, Trope GE, Jinapriya D, Jin YP, Buys YM. Prospective randomized study comparing ex-PRESS to trabeculectomy: 1-year results. J Glaucoma. 2015;24:624–9.CrossRef
7.
go back to reference Netland PA, Sarkisian SR Jr, Moster MR, Ahmed II, Condon G, Salim S, Sherwood MB, Siegfried CJ. Randomized, prospective, comparative trial of EX-PRESS glaucoma filtration device versus trabeculectomy (XVT study). Am J Ophthalmol 2014;157:433–440. Netland PA, Sarkisian SR Jr, Moster MR, Ahmed II, Condon G, Salim S, Sherwood MB, Siegfried CJ. Randomized, prospective, comparative trial of EX-PRESS glaucoma filtration device versus trabeculectomy (XVT study). Am J Ophthalmol 2014;157:433–440.
8.
go back to reference Allen RC, Bellows AR, Hutchinson BT, Murphy SD. Filtration surgery in the treatment of neovascular glaucoma. Ophthalmology. 1982;89:1181–7.CrossRef Allen RC, Bellows AR, Hutchinson BT, Murphy SD. Filtration surgery in the treatment of neovascular glaucoma. Ophthalmology. 1982;89:1181–7.CrossRef
9.
go back to reference Takihara Y, Inatani M, Fukushima M, Iwao K, Iwao M, Tanihara H. Trabeculectomy with mitomycin C for neovascular glaucoma: prognostic factors for surgical failure. Am J Ophthalmol. 2009;147:912–8.CrossRef Takihara Y, Inatani M, Fukushima M, Iwao K, Iwao M, Tanihara H. Trabeculectomy with mitomycin C for neovascular glaucoma: prognostic factors for surgical failure. Am J Ophthalmol. 2009;147:912–8.CrossRef
10.
go back to reference Kim YG, Hong S, Lee CS, Kang SY, Seong GJ, Ma KT, Kim CY. Level of vascular endothelial growth factor in aqueous humor and surgical results of Ahmed glaucoma valve implantation in patients with neovascular glaucoma. J Glaucoma. 2009;18:443–7.CrossRef Kim YG, Hong S, Lee CS, Kang SY, Seong GJ, Ma KT, Kim CY. Level of vascular endothelial growth factor in aqueous humor and surgical results of Ahmed glaucoma valve implantation in patients with neovascular glaucoma. J Glaucoma. 2009;18:443–7.CrossRef
11.
go back to reference Inoue T, Inatani M, Takihara Y, Awai-Kasaoka N, Ogata-Iwao M, Tanihara H. Prognostic risk factors for failure of trabeculectomy with mitomycin C after vitrectomy. Jpn J Ophthalmol. 2012;56:464–9.CrossRef Inoue T, Inatani M, Takihara Y, Awai-Kasaoka N, Ogata-Iwao M, Tanihara H. Prognostic risk factors for failure of trabeculectomy with mitomycin C after vitrectomy. Jpn J Ophthalmol. 2012;56:464–9.CrossRef
12.
go back to reference Ohira S, Inoue T, Shobayashi K, Iwao K, Fukushima M, Tanihara H. Simultaneous increase in multiple proinflammatory cytokines in the aqueous humor in neovascular glaucoma with and without intravitreal bevacizumab injection. Invest Ophthalmol Vis Sci. 2015;56:3541–8.CrossRef Ohira S, Inoue T, Shobayashi K, Iwao K, Fukushima M, Tanihara H. Simultaneous increase in multiple proinflammatory cytokines in the aqueous humor in neovascular glaucoma with and without intravitreal bevacizumab injection. Invest Ophthalmol Vis Sci. 2015;56:3541–8.CrossRef
13.
go back to reference Takihara Y, Inatani M, Seto T, Iwao K, Iwao M, Inoue T, Kasaoka N, Murakami A, Futa R, Tanihara H. Trabeculectomy with mitomycin for open-angle Glaucoma in phakic vs pseudophakic eyes after phacoemulsification. Arch Ophthalmol. 2011;129:152–7.CrossRef Takihara Y, Inatani M, Seto T, Iwao K, Iwao M, Inoue T, Kasaoka N, Murakami A, Futa R, Tanihara H. Trabeculectomy with mitomycin for open-angle Glaucoma in phakic vs pseudophakic eyes after phacoemulsification. Arch Ophthalmol. 2011;129:152–7.CrossRef
14.
go back to reference Shaarawy TM, Sherwood MB, Grehn F. Guidelines on design and reporting of glaucoma surgical trials. Amsterdam, the Netherlands, Kugler publications, 2009. Shaarawy TM, Sherwood MB, Grehn F. Guidelines on design and reporting of glaucoma surgical trials. Amsterdam, the Netherlands, Kugler publications, 2009.
15.
go back to reference Kato N, Takahashi G, Kumegawa K, Kabata Y, Tsuneoka H. Indications and postoperative treatment for ex-PRESS® insertion in Japanese patients with glaucoma: comparison with standard trabeculectomy. Clin Ophthalmol. 2015;9:1491–8.CrossRef Kato N, Takahashi G, Kumegawa K, Kabata Y, Tsuneoka H. Indications and postoperative treatment for ex-PRESS® insertion in Japanese patients with glaucoma: comparison with standard trabeculectomy. Clin Ophthalmol. 2015;9:1491–8.CrossRef
16.
go back to reference Lyssek-Boroń A, Wylęgała A, Dobrowolski D, Kowalczyk E, Polanowska K, Wylęgała E. Evaluation of EX-PRESS glaucoma implant in elderly diabetic patients after 23G vitrectomy. Clin Interv Aging. 2017;12:653–8.CrossRef Lyssek-Boroń A, Wylęgała A, Dobrowolski D, Kowalczyk E, Polanowska K, Wylęgała E. Evaluation of EX-PRESS glaucoma implant in elderly diabetic patients after 23G vitrectomy. Clin Interv Aging. 2017;12:653–8.CrossRef
17.
go back to reference Guven Yilmaz S, Yildirim S, Degirmenci C, Ates H. Evaluation of ex-PRESS mini glaucoma shunt implantation with preoperative intracameral bevacizumab injection in refractory neovascular glaucoma. Eur J Ophthalmol. 2016;26:575–80.CrossRef Guven Yilmaz S, Yildirim S, Degirmenci C, Ates H. Evaluation of ex-PRESS mini glaucoma shunt implantation with preoperative intracameral bevacizumab injection in refractory neovascular glaucoma. Eur J Ophthalmol. 2016;26:575–80.CrossRef
18.
go back to reference Maris PJ Jr, Ishida K, Netland PA. Comparison of trabeculectomy with ex-PRESS miniature glaucoma device implanted under scleral flap. J Glaucoma 2007;16:1614–9. Maris PJ Jr, Ishida K, Netland PA. Comparison of trabeculectomy with ex-PRESS miniature glaucoma device implanted under scleral flap. J Glaucoma 2007;16:1614–9.
19.
go back to reference Good TJ, Kahook MY. Assessment of bleb morphologic features and postoperative outcomes after ex-PRESS drainage device implantation versus trabeculectomy. Am J Ophthalmol. 2011;151:507–13.CrossRef Good TJ, Kahook MY. Assessment of bleb morphologic features and postoperative outcomes after ex-PRESS drainage device implantation versus trabeculectomy. Am J Ophthalmol. 2011;151:507–13.CrossRef
20.
go back to reference Marzette L, Herndon LW. A comparison of the ex-PRESS mini glaucoma shunt with standard trabeculectomy in the surgical treatment of glaucoma. Ophthalmic Surg Lasers Imaging. 2011;42:453–9.CrossRef Marzette L, Herndon LW. A comparison of the ex-PRESS mini glaucoma shunt with standard trabeculectomy in the surgical treatment of glaucoma. Ophthalmic Surg Lasers Imaging. 2011;42:453–9.CrossRef
21.
go back to reference Shobayashi K, Inoue T, Kawai M, Iwao K, Ohira S, Kojima S, Kuroda U, Nakashima K, Tanihara H. Postoperative changes in aqueous monocyte chemotactic protein-1 levels and bleb morphology after trabeculectomy vs. ex-PRESS shunt surgery. PLoS One. 2015;10:e0139751.CrossRef Shobayashi K, Inoue T, Kawai M, Iwao K, Ohira S, Kojima S, Kuroda U, Nakashima K, Tanihara H. Postoperative changes in aqueous monocyte chemotactic protein-1 levels and bleb morphology after trabeculectomy vs. ex-PRESS shunt surgery. PLoS One. 2015;10:e0139751.CrossRef
22.
go back to reference Kojima S, Inatani M, Shobayashi K, Haga A, Inoue T, Tanihara H. Risk factors for hyphema after trabeculectomy with mitomycin C. J Glaucoma. 2014;23:307–11.CrossRef Kojima S, Inatani M, Shobayashi K, Haga A, Inoue T, Tanihara H. Risk factors for hyphema after trabeculectomy with mitomycin C. J Glaucoma. 2014;23:307–11.CrossRef
23.
go back to reference Tsai JC, Feuer WJ, Parrish RK 2nd, Grajewski AL. 5-fluorouracil filtering surgery and neovascular glaucoma. Long-term follow-up of the original pilot study. Ophthalmology. 1995;102:887–92; discussion:892-3.CrossRef Tsai JC, Feuer WJ, Parrish RK 2nd, Grajewski AL. 5-fluorouracil filtering surgery and neovascular glaucoma. Long-term follow-up of the original pilot study. Ophthalmology. 1995;102:887–92; discussion:892-3.CrossRef
24.
go back to reference Sidoti PA, Dunphy TR, Baerveldt G, LaBree L, Minckler DS, Lee PP, Heuer DK. Experience with the Baerveldt glaucoma implant in treating neovascular glaucoma. Ophthalmology. 1995;102:1107–18.CrossRef Sidoti PA, Dunphy TR, Baerveldt G, LaBree L, Minckler DS, Lee PP, Heuer DK. Experience with the Baerveldt glaucoma implant in treating neovascular glaucoma. Ophthalmology. 1995;102:1107–18.CrossRef
25.
go back to reference Mermoud A, Salmon JF, Alexander P, Straker C, Murray AD. Molteno tube implantation for neovascular glaucoma. Long-term results and factors influencing the outcome. Ophthalmology. 1993;100:897–902.CrossRef Mermoud A, Salmon JF, Alexander P, Straker C, Murray AD. Molteno tube implantation for neovascular glaucoma. Long-term results and factors influencing the outcome. Ophthalmology. 1993;100:897–902.CrossRef
Metadata
Title
Efficacy and safety of Ex-PRESS® mini shunt surgery versus trabeculectomy for neovascular glaucoma: a retrospective comparative study
Authors
Kazuyuki Kawabata
Kohei Shobayashi
Keiichiro Iwao
Eri Takahashi
Hidenobu Tanihara
Toshihiro Inoue
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2019
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-019-1083-4

Other articles of this Issue 1/2019

BMC Ophthalmology 1/2019 Go to the issue