Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 6/2020

01-06-2020 | Glaucoma | Glaucoma

Dynamics of structural reversal in Bruch’s membrane opening-based morphometrics after glaucoma drainage device surgery

Authors: Caroline Gietzelt, Corinna von Goscinski, Julia Lemke, Friederike Schaub, Manuel M. Hermann, Thomas S. Dietlein, Claus Cursiefen, Ludwig M. Heindl, Philip Enders

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 6/2020

Login to get access

Abstract

Purpose

Structural reversal of disc cupping is a known phenomenon after trabeculectomy. The aim of this retrospective, longitudinal, cross-sectional analysis was to evaluate the postoperative dynamics of Bruch’s membrane opening-based morphometrics of the optic nerve head following glaucoma drainage device surgery.

Methods

Forty-three eyes, treated by glaucoma drainage device surgery, were included in the study. Individual changes in the spectral domain optic coherence tomography (SD-OCT) parameters Bruch’s membrane opening minimum rim width (BMO-MRW), Bruch’s membrane opening minimum rim area (BMO-MRA) and peripapillary retinal nerve fiber layer (RNFL) thickness as well as mean defect in 30–2 perimetry were analyzed. Changes were correlated to postoperative intraocular pressure levels over time. Available follow-up visits were aggregated and grouped into a short-term follow-up (20 to 180 days after surgery), a midterm follow-up (181 to 360 days after surgery) and a long-term follow-up (more than 360 days after surgery).

Results

In short-term follow-up, BMO-MRW and BMO-MRA increased significantly (p <= 0.034). This increase correlated negatively with the intraocular pressure at the time of the follow-up (Pearson’s rho = − 0.49; p = 0.039). From 6 months after surgery on, there was no statistically significant change in BMO-MRW and BMO-MRA (p >= 0.207). RNFL thickness and mean defect of 30–2 perimetry showed no significant changes after GDD implantation (p >= 0.189).

Conclusions

Lowering of intraocular pressure by glaucoma drainage device surgery leads to an increase of Bruch’s membrane opening based parameters in the first 6 months after surgery. These changes have to be taken into account when evaluating patients’ longitudinal follow-up after glaucoma drainage device implantation.
Literature
1.
go back to reference European Glaucoma Society (2017) Terminology and Guidelines for Glaucoma, 4th Edition. Br J Ophthalmol 101(5):73–127 European Glaucoma Society (2017) Terminology and Guidelines for Glaucoma, 4th Edition. Br J Ophthalmol 101(5):73–127
2.
go back to reference Chauhan BC, O'Leary N, AlMobarak FA, Reis ASC, Yang H, Sharpe GP, Hutchison DM, Nicolela MT, Burgoyne CF (2013) Enhanced detection of open-angle glaucoma with an anatomically accurate optical coherence tomography-derived neuroretinal rim parameter. Ophthalmology 120(3):535–543PubMed Chauhan BC, O'Leary N, AlMobarak FA, Reis ASC, Yang H, Sharpe GP, Hutchison DM, Nicolela MT, Burgoyne CF (2013) Enhanced detection of open-angle glaucoma with an anatomically accurate optical coherence tomography-derived neuroretinal rim parameter. Ophthalmology 120(3):535–543PubMed
3.
go back to reference Chauhan BC, Danthurebandara VM, Sharpe GP, Demirel S, Girkin CA, Mardin CY, Scheuerle AF, Burgoyne CF (2015) Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness in a normal white population: a multicenter study. Ophthalmology 122(9):1786–1794PubMedPubMedCentral Chauhan BC, Danthurebandara VM, Sharpe GP, Demirel S, Girkin CA, Mardin CY, Scheuerle AF, Burgoyne CF (2015) Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness in a normal white population: a multicenter study. Ophthalmology 122(9):1786–1794PubMedPubMedCentral
4.
go back to reference Gardiner SK, Ren R, Yang H, Fortune B, Burgoyne CF, Demirel S (2014) A method to estimate the amount of neuroretinal rim tissue in glaucoma: comparison with current methods for measuring rim area. Am J Ophthalmol 157(3):540–549PubMed Gardiner SK, Ren R, Yang H, Fortune B, Burgoyne CF, Demirel S (2014) A method to estimate the amount of neuroretinal rim tissue in glaucoma: comparison with current methods for measuring rim area. Am J Ophthalmol 157(3):540–549PubMed
5.
go back to reference Enders P, Adler W, Kiessling D, Weber V, Schaub F, Hermann MM, Dietlein T, Cursiefen C, Heindl LM (2018) Evaluation of two-dimensional Bruch's membrane opening minimum rim area for glaucoma diagnostics in a large patient cohort. Acta Ophthalmol 24(10):13698 Enders P, Adler W, Kiessling D, Weber V, Schaub F, Hermann MM, Dietlein T, Cursiefen C, Heindl LM (2018) Evaluation of two-dimensional Bruch's membrane opening minimum rim area for glaucoma diagnostics in a large patient cohort. Acta Ophthalmol 24(10):13698
6.
go back to reference Enders P, Schaub F, Adler W, Hermann MM, Dietlein TS, Cursiefen C, Heindl LM (2018) Bruch's membrane opening-based optical coherence tomography of the optic nerve head: a useful diagnostic tool to detect glaucoma in macrodiscs. Eye 32(2):314–323PubMedPubMedCentral Enders P, Schaub F, Adler W, Hermann MM, Dietlein TS, Cursiefen C, Heindl LM (2018) Bruch's membrane opening-based optical coherence tomography of the optic nerve head: a useful diagnostic tool to detect glaucoma in macrodiscs. Eye 32(2):314–323PubMedPubMedCentral
7.
go back to reference Enders P, Schaub F, Adler W, Nikoluk R, Hermann MM, Heindl LM (2017) The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs. Br J Ophthalmol 101(4):530–535PubMed Enders P, Schaub F, Adler W, Nikoluk R, Hermann MM, Heindl LM (2017) The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs. Br J Ophthalmol 101(4):530–535PubMed
8.
go back to reference Gardiner SK, Boey PY, Yang H, Fortune B, Burgoyne CF, Demirel S (2015) Structural measurements for monitoring change in glaucoma: comparing retinal nerve fiber layer thickness with minimum rim width and area. Invest Ophthalmol Vis Sci 56(11):6886–6891PubMedPubMedCentral Gardiner SK, Boey PY, Yang H, Fortune B, Burgoyne CF, Demirel S (2015) Structural measurements for monitoring change in glaucoma: comparing retinal nerve fiber layer thickness with minimum rim width and area. Invest Ophthalmol Vis Sci 56(11):6886–6891PubMedPubMedCentral
9.
go back to reference Enders P, Bremen A, Schaub F, Hermann MM, Diestelhorst M, Dietlein T, Cursiefen C, Heindl LM (2017) Intraday repeatability of Bruch's membrane opening-based neuroretinal rim measurements. Invest Ophthalmol Vis Sci 58(12):5195–5200PubMed Enders P, Bremen A, Schaub F, Hermann MM, Diestelhorst M, Dietlein T, Cursiefen C, Heindl LM (2017) Intraday repeatability of Bruch's membrane opening-based neuroretinal rim measurements. Invest Ophthalmol Vis Sci 58(12):5195–5200PubMed
10.
go back to reference Waisbourd M, Ahmed OM, Molineaux J, Gonzalez A, Spaeth GL, Katz LJ (2016) Reversible structural and functional changes after intraocular pressure reduction in patients with glaucoma. Graefes Arch Clin Exp Ophthalmol 254(6):1159–1166PubMed Waisbourd M, Ahmed OM, Molineaux J, Gonzalez A, Spaeth GL, Katz LJ (2016) Reversible structural and functional changes after intraocular pressure reduction in patients with glaucoma. Graefes Arch Clin Exp Ophthalmol 254(6):1159–1166PubMed
11.
go back to reference Quigley HA (1982) Childhood glaucoma: results with trabeculotomy and study of reversible cupping. Ophthalmology 89(3):219–226PubMed Quigley HA (1982) Childhood glaucoma: results with trabeculotomy and study of reversible cupping. Ophthalmology 89(3):219–226PubMed
12.
go back to reference Katz LJ, Spaeth GL, Cantor LB, Poryzees EM, Steinmann WC (1989) Reversible optic disk cupping and visual field improvement in adults with glaucoma. Am J Ophthalmol 107(5):485–492PubMed Katz LJ, Spaeth GL, Cantor LB, Poryzees EM, Steinmann WC (1989) Reversible optic disk cupping and visual field improvement in adults with glaucoma. Am J Ophthalmol 107(5):485–492PubMed
13.
go back to reference Lesk MR, Spaeth GL, Azuara-Blanco A, Araujo SV, Katz LJ, Terebuh AK, Wilson RP, Moster MR, Schmidt CM (1999) Reversal of optic disc cupping after glaucoma surgery analyzed with a scanning laser tomograph. Ophthalmology 106(5):1013–1018PubMed Lesk MR, Spaeth GL, Azuara-Blanco A, Araujo SV, Katz LJ, Terebuh AK, Wilson RP, Moster MR, Schmidt CM (1999) Reversal of optic disc cupping after glaucoma surgery analyzed with a scanning laser tomograph. Ophthalmology 106(5):1013–1018PubMed
14.
go back to reference Kotecha A, Siriwardena D, Fitzke FW, Hitchings RA, Khaw PT (2001) Optic disc changes following trabeculectomy: longitudinal and localisation of change. Br J Ophthalmol 85(8):956–961PubMedPubMedCentral Kotecha A, Siriwardena D, Fitzke FW, Hitchings RA, Khaw PT (2001) Optic disc changes following trabeculectomy: longitudinal and localisation of change. Br J Ophthalmol 85(8):956–961PubMedPubMedCentral
15.
go back to reference Parrish RK, Feuer WJ, Schiffman JC, Lichter PR, Musch DC (2009) Five-year follow-up optic disc findings of the collaborative initial glaucoma treatment study. Am J Ophthalmol 147(4):717–724PubMedPubMedCentral Parrish RK, Feuer WJ, Schiffman JC, Lichter PR, Musch DC (2009) Five-year follow-up optic disc findings of the collaborative initial glaucoma treatment study. Am J Ophthalmol 147(4):717–724PubMedPubMedCentral
16.
go back to reference Gietzelt C, Lemke J, Schaub F, Hermann MM, Dietlein TS, Cursiefen C, Enders P, Heindl LM (2018) Structural reversal of disc cupping after trabeculectomy alters Bruch membrane opening-based parameters to assess neuroretinal rim. Am J Ophthalmol 194:143–152PubMed Gietzelt C, Lemke J, Schaub F, Hermann MM, Dietlein TS, Cursiefen C, Enders P, Heindl LM (2018) Structural reversal of disc cupping after trabeculectomy alters Bruch membrane opening-based parameters to assess neuroretinal rim. Am J Ophthalmol 194:143–152PubMed
17.
go back to reference Kiessling D, Christ H, Gietzelt C, Schaub F, Dietlein TS, Cursiefen C, Heindl LM, Enders P (2018) Impact of ab-interno trabeculectomy on Bruch's membrane opening-based morphometry of the optic nerve head for glaucoma progression analysis. Graefes Arch Clin Exp Ophthalmol 28(10):018–4187 Kiessling D, Christ H, Gietzelt C, Schaub F, Dietlein TS, Cursiefen C, Heindl LM, Enders P (2018) Impact of ab-interno trabeculectomy on Bruch's membrane opening-based morphometry of the optic nerve head for glaucoma progression analysis. Graefes Arch Clin Exp Ophthalmol 28(10):018–4187
20.
go back to reference Ramulu PY, Corcoran KJ, Corcoran SL, Robin AL (2007) Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995 to 2004. Ophthalmology 114(12):2265–2270PubMed Ramulu PY, Corcoran KJ, Corcoran SL, Robin AL (2007) Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995 to 2004. Ophthalmology 114(12):2265–2270PubMed
21.
go back to reference Dietlein TS, Rosentreter A (2018) Surgical options in Glaucoma management. Klin Monatsbl Augenheilkd 235(9):1013–1020PubMed Dietlein TS, Rosentreter A (2018) Surgical options in Glaucoma management. Klin Monatsbl Augenheilkd 235(9):1013–1020PubMed
22.
go back to reference Gedde SJ, Schiffman JC, Feuer WJ, Herndon LW, Brandt JD, Budenz DL (2012) Treatment outcomes in the tube versus trabeculectomy (TVT) study after five years of follow-up. Am J Ophthalmol 153(5):789–803PubMedPubMedCentral Gedde SJ, Schiffman JC, Feuer WJ, Herndon LW, Brandt JD, Budenz DL (2012) Treatment outcomes in the tube versus trabeculectomy (TVT) study after five years of follow-up. Am J Ophthalmol 153(5):789–803PubMedPubMedCentral
23.
go back to reference Wang YW, Wang PB, Zeng C, Xia XB (2015) Comparison of the Ahmed glaucoma valve with the Baerveldt glaucoma implant: a meta-analysis. BMC Ophthalmol 15(132):015–0115 Wang YW, Wang PB, Zeng C, Xia XB (2015) Comparison of the Ahmed glaucoma valve with the Baerveldt glaucoma implant: a meta-analysis. BMC Ophthalmol 15(132):015–0115
24.
go back to reference Hollo G (2017) Comparison of structure-function relationship between corresponding retinal nerve fibre layer thickness and Octopus visual field cluster defect values determined by normal and tendency-oriented strategies. Br J Ophthalmol 101(2):150–154PubMed Hollo G (2017) Comparison of structure-function relationship between corresponding retinal nerve fibre layer thickness and Octopus visual field cluster defect values determined by normal and tendency-oriented strategies. Br J Ophthalmol 101(2):150–154PubMed
25.
go back to reference King AJ, Taguri A, Wadood AC, Azuara-Blanco A (2002) Comparison of two fast strategies, SITA fast and TOP, for the assessment of visual fields in glaucoma patients. Graefes Arch Clin Exp Ophthalmol 240(6):481–487PubMed King AJ, Taguri A, Wadood AC, Azuara-Blanco A (2002) Comparison of two fast strategies, SITA fast and TOP, for the assessment of visual fields in glaucoma patients. Graefes Arch Clin Exp Ophthalmol 240(6):481–487PubMed
26.
go back to reference Wadood AC, Azuara-Blanco A, Aspinall P, Taguri A, King AJ (2002) Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice. Am J Ophthalmol 133(3):327–332PubMed Wadood AC, Azuara-Blanco A, Aspinall P, Taguri A, King AJ (2002) Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice. Am J Ophthalmol 133(3):327–332PubMed
27.
go back to reference Rosentreter A, Gaki S, Lappas A, Cursiefen C, Dietlein TS (2013) Previous cyclodestruction is a risk factor for late-onset hypotony and suprachoroidal haemorrhage after glaucoma drainage device surgery. Br J Ophthalmol 97(6):715–719PubMed Rosentreter A, Gaki S, Lappas A, Cursiefen C, Dietlein TS (2013) Previous cyclodestruction is a risk factor for late-onset hypotony and suprachoroidal haemorrhage after glaucoma drainage device surgery. Br J Ophthalmol 97(6):715–719PubMed
28.
go back to reference Mansberger SL, Menda SA, Fortune BA, Gardiner SK, Demirel S (2017) Automated segmentation errors when using optical coherence tomography to measure retinal nerve fiber layer thickness in glaucoma. Am J Ophthalmol 174:1–8PubMed Mansberger SL, Menda SA, Fortune BA, Gardiner SK, Demirel S (2017) Automated segmentation errors when using optical coherence tomography to measure retinal nerve fiber layer thickness in glaucoma. Am J Ophthalmol 174:1–8PubMed
29.
go back to reference Mariotti C, Nicolai M, Longo A, Viti F, Bambini E, Saitta A, Pirani V, Orsini E, Baruffa D, Reibaldi M (2017) Peripapillary retinal nerve fiber thickness changes after vitrectomy for epiretinal membrane in eyes with and without vitreous detachment. Retina 37(12):2304–2309PubMed Mariotti C, Nicolai M, Longo A, Viti F, Bambini E, Saitta A, Pirani V, Orsini E, Baruffa D, Reibaldi M (2017) Peripapillary retinal nerve fiber thickness changes after vitrectomy for epiretinal membrane in eyes with and without vitreous detachment. Retina 37(12):2304–2309PubMed
30.
go back to reference Irak I, Zangwill L, Garden V, Shakiba S, Weinreb RN (1996) Change in optic disk topography after trabeculectomy. Am J Ophthalmol 122(5):690–695PubMed Irak I, Zangwill L, Garden V, Shakiba S, Weinreb RN (1996) Change in optic disk topography after trabeculectomy. Am J Ophthalmol 122(5):690–695PubMed
31.
go back to reference Topouzis F, Peng F, Kotas-Neumann R, Garcia R, Sanguinet J, Yu F, Coleman AL (1999) Longitudinal changes in optic disc topography of adult patients after trabeculectomy. Ophthalmology 106(6):1147–1151PubMed Topouzis F, Peng F, Kotas-Neumann R, Garcia R, Sanguinet J, Yu F, Coleman AL (1999) Longitudinal changes in optic disc topography of adult patients after trabeculectomy. Ophthalmology 106(6):1147–1151PubMed
32.
go back to reference Fortune B, Yang H, Strouthidis NG, Cull GA, Grimm JL, Downs JC, Burgoyne CF (2009) The effect of acute intraocular pressure elevation on peripapillary retinal thickness, retinal nerve fiber layer thickness, and retardance. Invest Ophthalmol Vis Sci 50(10):4719–4726PubMedPubMedCentral Fortune B, Yang H, Strouthidis NG, Cull GA, Grimm JL, Downs JC, Burgoyne CF (2009) The effect of acute intraocular pressure elevation on peripapillary retinal thickness, retinal nerve fiber layer thickness, and retardance. Invest Ophthalmol Vis Sci 50(10):4719–4726PubMedPubMedCentral
33.
go back to reference Strouthidis NG, Fortune B, Yang H, Sigal IA, Burgoyne CF (2011) Longitudinal change detected by spectral domain optical coherence tomography in the optic nerve head and peripapillary retina in experimental glaucoma. Invest Ophthalmol Vis Sci 52(3):1206–1219PubMedPubMedCentral Strouthidis NG, Fortune B, Yang H, Sigal IA, Burgoyne CF (2011) Longitudinal change detected by spectral domain optical coherence tomography in the optic nerve head and peripapillary retina in experimental glaucoma. Invest Ophthalmol Vis Sci 52(3):1206–1219PubMedPubMedCentral
34.
go back to reference Coleman AL, Quigley HA, Vitale S, Dunkelberger G (1991) Displacement of the optic nerve head by acute changes in intraocular pressure in monkey eyes. Ophthalmology 98(1):35–40PubMed Coleman AL, Quigley HA, Vitale S, Dunkelberger G (1991) Displacement of the optic nerve head by acute changes in intraocular pressure in monkey eyes. Ophthalmology 98(1):35–40PubMed
Metadata
Title
Dynamics of structural reversal in Bruch’s membrane opening-based morphometrics after glaucoma drainage device surgery
Authors
Caroline Gietzelt
Corinna von Goscinski
Julia Lemke
Friederike Schaub
Manuel M. Hermann
Thomas S. Dietlein
Claus Cursiefen
Ludwig M. Heindl
Philip Enders
Publication date
01-06-2020
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 6/2020
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-020-04621-y

Other articles of this Issue 6/2020

Graefe's Archive for Clinical and Experimental Ophthalmology 6/2020 Go to the issue