Skip to main content
Top
Published in: BMC Oral Health 1/2022

Open Access 01-12-2022 | Gingiva Index | Research

Clinical and radiographic prospective study of customized one-piece titanium and one-piece fusion-sputtered zirconia implants: five-year mean follow-up

Authors: Mahy Hassouna, Walid Al-Zordk, Moustafa Aboshilib, Mohamed Ghazy

Published in: BMC Oral Health | Issue 1/2022

Login to get access

Abstract

Background

To evaluate the clinical and radiographic assessment of customized fusion-sputtered one-piece zirconia implants.

Methods

Twenty-eight patients received either fusion sputtered one-piece zirconia implants (n = 14) or one-piece titanium implants (n = 14). All implants were one-piece designs. After 4 months of immediate loading, all implants were restored with a monolithic zirconia crown. All implants were evaluated at baseline, 6 months, 1 year, 2 years, and 5 years. Implant mobility, plaque index, and gingival index evaluations were performed. The measurements of marginal bone level were calculated radiographically.

Results

All implants were well maintained through the evaluation period with a 100% survival rate without any clinical complications. Regarding gingival index, there was no statistically significant difference (P = .364) between zirconia (3.3 ± 0.7 mm) and titanium (3.5 ± 0.6 mm) implants, after 5 years. There was no statistically significant difference (P = .470) between zirconia (1.77 ± 0.039 mm) and titanium (1.80 ± 0.28 mm) implants regarding marginal bone loss, after 5 years.

Conclusions

One-piece fusion-sputtered zirconia implant represents a reliable treatment modality in replacing a missing tooth in the esthetic zone.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bassir SH, El Kholy K, Chen C-Y, Lee KH, Intini G. Outcome of early dental implant placement versus other dentalimplant placement protocols: a systematic review and meta-analysis. J Periodontol. 2019;90:493–506.PubMed Bassir SH, El Kholy K, Chen C-Y, Lee KH, Intini G. Outcome of early dental implant placement versus other dentalimplant placement protocols: a systematic review and meta-analysis. J Periodontol. 2019;90:493–506.PubMed
2.
go back to reference Albrektsson T, Wennerberg A. The impact of oral implants; past and future, 1966–2042. J Can Dent Assoc. 2005;71:327–31.PubMed Albrektsson T, Wennerberg A. The impact of oral implants; past and future, 1966–2042. J Can Dent Assoc. 2005;71:327–31.PubMed
3.
go back to reference Misch CE, Wang HL, Misch CM, Sharawy M, Lemons J, Judy KW. Rationale for the application of immediate load in implant dentistry: part I. Implant Dent. 2004;13:207–17.PubMed Misch CE, Wang HL, Misch CM, Sharawy M, Lemons J, Judy KW. Rationale for the application of immediate load in implant dentistry: part I. Implant Dent. 2004;13:207–17.PubMed
4.
go back to reference Goiato MC, Pellizzer EP, dos Santos DM, Batao V, de Carvalho B, Magro-Filho O, et al. Clinical viability of immediate loading of dental implants: part I—factors for success. J Craniofac Surg. 2009;20:2139–42.PubMed Goiato MC, Pellizzer EP, dos Santos DM, Batao V, de Carvalho B, Magro-Filho O, et al. Clinical viability of immediate loading of dental implants: part I—factors for success. J Craniofac Surg. 2009;20:2139–42.PubMed
5.
go back to reference Misch CE, Wang HL, Misch CM, Sharawy M, Lemons J, Judy KW. Rationale for the application of immediate load in implant dentistry: part II. Implant Dent. 2004;13:310–21.PubMed Misch CE, Wang HL, Misch CM, Sharawy M, Lemons J, Judy KW. Rationale for the application of immediate load in implant dentistry: part II. Implant Dent. 2004;13:310–21.PubMed
6.
go back to reference Schroeder A, van der Zypen E, Stich H, Sutter F. The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces. J Oral Maxillofac Surg. 1981;9:15–25. Schroeder A, van der Zypen E, Stich H, Sutter F. The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces. J Oral Maxillofac Surg. 1981;9:15–25.
7.
go back to reference Olmedo D, Fernandez MM, Guglielmotti MB, Cabrini RL. Macrophages related to dental implant failure. Implant Dent. 2003;12:75–80.PubMed Olmedo D, Fernandez MM, Guglielmotti MB, Cabrini RL. Macrophages related to dental implant failure. Implant Dent. 2003;12:75–80.PubMed
8.
go back to reference Frisken KW, Dandie GW, Lugowski S, Jordan G. A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust Dent J. 2002;47:214–7.PubMed Frisken KW, Dandie GW, Lugowski S, Jordan G. A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust Dent J. 2002;47:214–7.PubMed
9.
go back to reference Muller K, Valentine-Thon E. Hypersensitivity to titanium: clinical and laboratory evidence. Neuro Endocrinol Lett. 2006;27:31–5.PubMed Muller K, Valentine-Thon E. Hypersensitivity to titanium: clinical and laboratory evidence. Neuro Endocrinol Lett. 2006;27:31–5.PubMed
10.
go back to reference Covacci V, Bruzzese N, Maccauro G, Andreassi C, Ricci G, Piconi C, et al. In vitro evaluation of the mutagenic and carcinogenic power of high purity zirconia ceramic. Biomaterials. 1999;20:371–6.PubMed Covacci V, Bruzzese N, Maccauro G, Andreassi C, Ricci G, Piconi C, et al. In vitro evaluation of the mutagenic and carcinogenic power of high purity zirconia ceramic. Biomaterials. 1999;20:371–6.PubMed
11.
go back to reference Kelly JR, Denry I. Stabilized zirconia as a structural ceramic: an overview. Dent Mater. 2008;24:289–98.PubMed Kelly JR, Denry I. Stabilized zirconia as a structural ceramic: an overview. Dent Mater. 2008;24:289–98.PubMed
12.
go back to reference Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999;20:1–25.PubMed Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999;20:1–25.PubMed
14.
go back to reference Fernandes PRE, et al. Clinical performance comparing titanium and titanium–zirconium or zirconia dental implants: a systematic review of randomized controlled trials. Dent J (Basel). 2022. Fernandes PRE, et al. Clinical performance comparing titanium and titanium–zirconium or zirconia dental implants: a systematic review of randomized controlled trials. Dent J (Basel). 2022.
15.
go back to reference Gahlert M, Gudehus T, Eichhorn S, Steinhauser E, Kniha H, Erhardt W. Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs. Clin Oral Implant Res. 2007;18:662–8. Gahlert M, Gudehus T, Eichhorn S, Steinhauser E, Kniha H, Erhardt W. Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs. Clin Oral Implant Res. 2007;18:662–8.
16.
go back to reference Meshramkar R, Shetty P, Nayak A, Anehosur GV. Surface treatment of zirconia implant, its surface roughness and its effect on osseointegration - a review. Int J Innov Res Med Sci. 2019;4:343–5. Meshramkar R, Shetty P, Nayak A, Anehosur GV. Surface treatment of zirconia implant, its surface roughness and its effect on osseointegration - a review. Int J Innov Res Med Sci. 2019;4:343–5.
17.
go back to reference Aboshelib M. Fusion sputtering for bonding to zirconia-based material. J Adhes Dent. 2012;14:323–8. Aboshelib M. Fusion sputtering for bonding to zirconia-based material. J Adhes Dent. 2012;14:323–8.
18.
go back to reference Salem N, Abo Taleb A, Aboushelib M. Biomechanical and histomorphometric evaluation of osseointegration of fusion-sputtered zirconia implants. J Prosthodont. 2013;22:261–7.PubMed Salem N, Abo Taleb A, Aboushelib M. Biomechanical and histomorphometric evaluation of osseointegration of fusion-sputtered zirconia implants. J Prosthodont. 2013;22:261–7.PubMed
19.
go back to reference Lang LA, Turkyilmaz I, Edgin WA, Verrett R, Garcia LT. Immediate restoration of single tapered implants with non occluding provisional crowns: a 5-year clinical prospective study. Clin Implant Dent Relat Res. 2014;2:248–58. Lang LA, Turkyilmaz I, Edgin WA, Verrett R, Garcia LT. Immediate restoration of single tapered implants with non occluding provisional crowns: a 5-year clinical prospective study. Clin Implant Dent Relat Res. 2014;2:248–58.
20.
go back to reference Osman RB, Swain MV, Atieh M, Ma S, Duncan W. Ceramic implants (Y-TZP): are they a viable alternative to titanium implants for the support of overdentures? A randomized clinical trial. Clin Oral Implants Res. 2014;25:1366–77.PubMed Osman RB, Swain MV, Atieh M, Ma S, Duncan W. Ceramic implants (Y-TZP): are they a viable alternative to titanium implants for the support of overdentures? A randomized clinical trial. Clin Oral Implants Res. 2014;25:1366–77.PubMed
21.
go back to reference Sadowsky SJ. Has zirconia made a material difference in implant prosthodontics? A review. Dent Mater. 2020;36:1–8.PubMed Sadowsky SJ. Has zirconia made a material difference in implant prosthodontics? A review. Dent Mater. 2020;36:1–8.PubMed
22.
go back to reference Yamashita D, Machigashira M, Miyamoto M, Takeuchi H, Noguchi K, Izumi Y, Ban S. Effect of surface roughness on initial responses of osteoblast-like cells on two types of zirconia. Dent Mater J. 2009;28:461–70.PubMed Yamashita D, Machigashira M, Miyamoto M, Takeuchi H, Noguchi K, Izumi Y, Ban S. Effect of surface roughness on initial responses of osteoblast-like cells on two types of zirconia. Dent Mater J. 2009;28:461–70.PubMed
23.
go back to reference Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modified zirconia implants: a histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res. 2005;7:s13–20.PubMed Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modified zirconia implants: a histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res. 2005;7:s13–20.PubMed
24.
go back to reference Schliephake H, Hefti T, Schlottig F, Gédet P, Staedt H. Mechanical anchorage and peri-implant bone formation of surface-modified zirconia in minipigs. J Clin Periodontol. 2010;37:818–28.PubMed Schliephake H, Hefti T, Schlottig F, Gédet P, Staedt H. Mechanical anchorage and peri-implant bone formation of surface-modified zirconia in minipigs. J Clin Periodontol. 2010;37:818–28.PubMed
25.
go back to reference Steyer E, Herber V, Koller M, Végh D, Mukaddam K, Jakse N, et al. Immediate restoration of single-piece zirconia implants: a prospective case series-long-term results after 11 years of clinical function. Materials. 2021;14:6738.PubMedPubMedCentral Steyer E, Herber V, Koller M, Végh D, Mukaddam K, Jakse N, et al. Immediate restoration of single-piece zirconia implants: a prospective case series-long-term results after 11 years of clinical function. Materials. 2021;14:6738.PubMedPubMedCentral
26.
go back to reference Hahn J. Clinical and radiographic evaluation of one-piece implants used for immediate function. J Oral Implantol. 2007;33:152–5.PubMed Hahn J. Clinical and radiographic evaluation of one-piece implants used for immediate function. J Oral Implantol. 2007;33:152–5.PubMed
27.
go back to reference Sohn D, Bae M, Heo J, Park J, Yea S, Romanos G. Retrospective multicenter analysis of immediate provisionalization using one-piece narrow-diameter (3.0-mm) implants. Int J Oral Maxillofac Implants. 2011;26:163–8.PubMed Sohn D, Bae M, Heo J, Park J, Yea S, Romanos G. Retrospective multicenter analysis of immediate provisionalization using one-piece narrow-diameter (3.0-mm) implants. Int J Oral Maxillofac Implants. 2011;26:163–8.PubMed
28.
go back to reference Pirker W, Wiedemann D, Lidauer A, Kocher A. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years followup. Int J Oral Maxillofac Surg. 2011;40:212–6.PubMed Pirker W, Wiedemann D, Lidauer A, Kocher A. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years followup. Int J Oral Maxillofac Surg. 2011;40:212–6.PubMed
29.
go back to reference Mangano C, Mangano F, Shibli JA, Ricci M, Perrotti V, d’Avila S, Piattelli A. Immediate loading of mandibular overdentures supported by unsplinted direct laser metal forming (DLMF) implants. Results from a 1-year prospective study. J Periodontol. 2012;83:70–8.PubMed Mangano C, Mangano F, Shibli JA, Ricci M, Perrotti V, d’Avila S, Piattelli A. Immediate loading of mandibular overdentures supported by unsplinted direct laser metal forming (DLMF) implants. Results from a 1-year prospective study. J Periodontol. 2012;83:70–8.PubMed
30.
go back to reference Moin DA, Hassan B, Mercelis P, Wismeijer D. Designing a novel dental root analogue implant using cone beam computed tomography and CAD/CAM technology. Clin Oral Implants Res. 2013;24:S25–7. Moin DA, Hassan B, Mercelis P, Wismeijer D. Designing a novel dental root analogue implant using cone beam computed tomography and CAD/CAM technology. Clin Oral Implants Res. 2013;24:S25–7.
31.
go back to reference Andrade MP, Sordi MB, Henriques B, Silva FS, Teughels W, Souza JC. Custom-made root-analogue zirconia implants: a scoping review on mechanical and biological benefits. J Biomed Mater Res B Appl Biomater. 2018;8:2888–900. Andrade MP, Sordi MB, Henriques B, Silva FS, Teughels W, Souza JC. Custom-made root-analogue zirconia implants: a scoping review on mechanical and biological benefits. J Biomed Mater Res B Appl Biomater. 2018;8:2888–900.
32.
go back to reference Figliuzzi M, Mangano F, Mangano C. A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology. Int J Oral Maxillofac Surg. 2012;41:858–62.PubMed Figliuzzi M, Mangano F, Mangano C. A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology. Int J Oral Maxillofac Surg. 2012;41:858–62.PubMed
33.
go back to reference Han A, Tsoi JK, Matinlinna JP, Zhang Y, Chen Z. Effects of different sterilization methods on surface characteristics and biofilm formation on zirconia in vitro. Dent Mater. 2018;34:272–81.PubMed Han A, Tsoi JK, Matinlinna JP, Zhang Y, Chen Z. Effects of different sterilization methods on surface characteristics and biofilm formation on zirconia in vitro. Dent Mater. 2018;34:272–81.PubMed
35.
go back to reference Albrektsson T, Eriksson A. Thermally induced bone necrosis in rabbits: relation to implant failure in humans. Clin Orthop Relat Res. 1985;195:311–2. Albrektsson T, Eriksson A. Thermally induced bone necrosis in rabbits: relation to implant failure in humans. Clin Orthop Relat Res. 1985;195:311–2.
36.
go back to reference Albrektsson T, Gottlow J, Meirelles L, Ostman PO, Rocci A, Sennerby L. Survival of Nobel Direct implants: an analysis of 550 consecutively placed implants at 18 different clinical centers. Clin Implant Dent Relat Res. 2007;9:65–70.PubMed Albrektsson T, Gottlow J, Meirelles L, Ostman PO, Rocci A, Sennerby L. Survival of Nobel Direct implants: an analysis of 550 consecutively placed implants at 18 different clinical centers. Clin Implant Dent Relat Res. 2007;9:65–70.PubMed
37.
go back to reference Ostman PO, Hellman M, Albrektsson T, Sennerby L. Direct loading of Nobel Direct and Nobel Perfect one-piece implants: a one-year prospective clinical and radiographic study. Clin Oral Implants Res. 2007;18:409–18.PubMed Ostman PO, Hellman M, Albrektsson T, Sennerby L. Direct loading of Nobel Direct and Nobel Perfect one-piece implants: a one-year prospective clinical and radiographic study. Clin Oral Implants Res. 2007;18:409–18.PubMed
38.
go back to reference Sennerby L, Rocci A, Becker W, Jonsson L, Johansson LA, Albrektsson T. Short-term clinical results of Nobel Direct implants: a retrospective multicentre analysis. Clin Oral Implants Res. 2008;19:219–26.PubMed Sennerby L, Rocci A, Becker W, Jonsson L, Johansson LA, Albrektsson T. Short-term clinical results of Nobel Direct implants: a retrospective multicentre analysis. Clin Oral Implants Res. 2008;19:219–26.PubMed
39.
go back to reference Finne K, Rompen E, Toljanic J. Clinical evaluation of a prospective multicenter study on one-piece implants. Part 1: marginal bone level evaluation after one year of follow-up. Int J Oral Maxillofac Implants. 2007;22:226–34.PubMed Finne K, Rompen E, Toljanic J. Clinical evaluation of a prospective multicenter study on one-piece implants. Part 1: marginal bone level evaluation after one year of follow-up. Int J Oral Maxillofac Implants. 2007;22:226–34.PubMed
40.
go back to reference Russe P, Pascaretti-Grizon F, Aguado E, Goyenvale E, Filmon R, Basle M, Chappard D. Does milling one-piece titanium dental implants induce osteocyte and osteoclast changes. Morphologie. 2011;95:51–9.PubMed Russe P, Pascaretti-Grizon F, Aguado E, Goyenvale E, Filmon R, Basle M, Chappard D. Does milling one-piece titanium dental implants induce osteocyte and osteoclast changes. Morphologie. 2011;95:51–9.PubMed
41.
go back to reference Galli F, Capelli M, Zuffetti F, Testori T, Esposito M. Immediate non-occlusal vs. early loading of dental implants in partially edentulous patients: a multicentre randomized clinical trial. Peri-implant bone and soft-tissue levels. Clin Oral Implants Res. 2008;19:546–52.PubMed Galli F, Capelli M, Zuffetti F, Testori T, Esposito M. Immediate non-occlusal vs. early loading of dental implants in partially edentulous patients: a multicentre randomized clinical trial. Peri-implant bone and soft-tissue levels. Clin Oral Implants Res. 2008;19:546–52.PubMed
42.
go back to reference Rohr N, Brunner S, Märtin S, Fischer J. Influence of cement type and ceramic primer on retention of polymer-infiltrated ceramic crowns to a one-piece zirconia implant. J Prosthetic Dent. 2017;119:138–45. Rohr N, Brunner S, Märtin S, Fischer J. Influence of cement type and ceramic primer on retention of polymer-infiltrated ceramic crowns to a one-piece zirconia implant. J Prosthetic Dent. 2017;119:138–45.
43.
go back to reference Rutkowski R, Smeets R, Neuhöffer L, Stolzer C, Strick K, Gosau M, et al. Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading. BMC Oral Health. 2022;22:198.PubMedPubMedCentral Rutkowski R, Smeets R, Neuhöffer L, Stolzer C, Strick K, Gosau M, et al. Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading. BMC Oral Health. 2022;22:198.PubMedPubMedCentral
44.
go back to reference Golab K, Balouch A, Mirtorabi S. One-year multicenter prospective evaluation of survival rates and bone resorption in one-piece implants. Clin Implant Dent Relat Res. 2016;18:392–400. Golab K, Balouch A, Mirtorabi S. One-year multicenter prospective evaluation of survival rates and bone resorption in one-piece implants. Clin Implant Dent Relat Res. 2016;18:392–400.
45.
go back to reference Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol. 2004;75:292–6.PubMed Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol. 2004;75:292–6.PubMed
47.
go back to reference Lindquist LW, Carlsson GE, Jemt T. A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss. Clin Oral Implants Res. 1996;7:329–36.PubMed Lindquist LW, Carlsson GE, Jemt T. A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss. Clin Oral Implants Res. 1996;7:329–36.PubMed
48.
go back to reference Spies BC, Balmer M. All-ceramic single crowns supported by zirconia implants: 5-year results of a prospective multicenter study. Clin Oral Implants Res. 2019;30:466–75.PubMed Spies BC, Balmer M. All-ceramic single crowns supported by zirconia implants: 5-year results of a prospective multicenter study. Clin Oral Implants Res. 2019;30:466–75.PubMed
49.
go back to reference Albrektsson T, Isidor F. Consensus report session IV. London. In: Lang NP, Karring T, editors. Proceedings of the 1st European workshop on periodontology. London: Quintessence Publ; 1994. p. 365–9. Albrektsson T, Isidor F. Consensus report session IV. London. In: Lang NP, Karring T, editors. Proceedings of the 1st European workshop on periodontology. London: Quintessence Publ; 1994. p. 365–9.
50.
go back to reference Kohal RJ, Spies BC, Bauer A, Butz F. One-piece zirconia oral implants for single-tooth replacement: three-year results from a long-term prospective cohort study. J Clin Periodontol. 2018;45(1):114–24.PubMed Kohal RJ, Spies BC, Bauer A, Butz F. One-piece zirconia oral implants for single-tooth replacement: three-year results from a long-term prospective cohort study. J Clin Periodontol. 2018;45(1):114–24.PubMed
51.
go back to reference Kohal RJ, Knauf M, Larsson B, Sahlin H, Butz F. One-piece zirconia oral implants: one-year results from a prospective cohort study 1 Single tooth replacement. J Clin Periodontol. 2012;39(6):590–7.PubMed Kohal RJ, Knauf M, Larsson B, Sahlin H, Butz F. One-piece zirconia oral implants: one-year results from a prospective cohort study 1 Single tooth replacement. J Clin Periodontol. 2012;39(6):590–7.PubMed
52.
go back to reference Kniha K, Milz S, Kniha H, Ayoub N, Hölzle F, Modabber A. Peri-implant crestal bone changes around zirconia implants in periodontally healthy and compromised patients. Int J Oral Maxillofac Implants. 2018;33(1):217–22.PubMed Kniha K, Milz S, Kniha H, Ayoub N, Hölzle F, Modabber A. Peri-implant crestal bone changes around zirconia implants in periodontally healthy and compromised patients. Int J Oral Maxillofac Implants. 2018;33(1):217–22.PubMed
54.
go back to reference Wyatt C, Bryant S, Avivi-Arber L, Chaytor D, Zarb G. A computer-assisted measurement technique to assess bone proximal to oral implants on intraoral radiographs. Clin Oral Implants Res. 2001;12:225–9.PubMed Wyatt C, Bryant S, Avivi-Arber L, Chaytor D, Zarb G. A computer-assisted measurement technique to assess bone proximal to oral implants on intraoral radiographs. Clin Oral Implants Res. 2001;12:225–9.PubMed
Metadata
Title
Clinical and radiographic prospective study of customized one-piece titanium and one-piece fusion-sputtered zirconia implants: five-year mean follow-up
Authors
Mahy Hassouna
Walid Al-Zordk
Moustafa Aboshilib
Mohamed Ghazy
Publication date
01-12-2022
Publisher
BioMed Central
Keyword
Gingiva Index
Published in
BMC Oral Health / Issue 1/2022
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-022-02600-9

Other articles of this Issue 1/2022

BMC Oral Health 1/2022 Go to the issue