Abstract

Purpose

To investigate the effects of a trial femoral component on the intraoperative joint gap and intraoperative joint gap kinematics throughout the range of knee motion in minimally invasive surgery–total knee arthroplasty (MIS–TKA) with the gap technique.

Materials and methods

A total of 103 patients [15 men (15 knees) and 89 women (89 knees)] aged 50–88 years (mean 74.8 years) who received MIS–TKA with the gap technique were included. The intraoperative joint gap differences (90° flexion gap distance minus 0° extension gap distance) with and without the trial femoral component were compared. Subsequently, the intraoperative joint gap kinematics at 0°, 45°, 90°, and 120° with the trial femoral component were investigated.

Results

The intraoperative component gap difference (4.4 ± 2.7 mm) was larger than the estimated joint gap difference (1.2 ± 1.9 mm) (p < 0.01). The mean intraoperative component gap distances at 0°, 45°, 90°, and 120° of knee flexion were 14.7 ± 2.6, 19.0 ± 3.2, 19.2 ± 3.4, and 16.6 ± 3.3 mm, respectively. The intraoperative component gap distance increased significantly from 0° extension to 90° of knee flexion (p < 0.01), and then decreased significantly toward deep knee flexion at 120° (p < 0.01).

Conclusions

The trial femoral component influenced the intraoperative gap measurements, and increased the intraoperative gap difference. The joint gap kinematics with the trial femoral component were not constant throughout the range of knee motion, even if the appropriate joint gaps in extension and flexion were achieved. For acquisition of constant stability throughout the knee motion, the present results should be taken into account by surgeons performing MIS–TKA with the gap technique.
Literature
1.
go back to reference Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M (2001) Early failures in total knee arthroplasty. Clin Orthop Relat Res 392:315–318PubMedCrossRef Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M (2001) Early failures in total knee arthroplasty. Clin Orthop Relat Res 392:315–318PubMedCrossRef
3.
go back to reference Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kurosaka M, Kuroda R (2011) The influence of preoperative deformity on intraoperative soft tissue balance in posterior-stabilized total knee arthroplasty. J Arthroplast 26:1291–1298. doi:10.1016/j.arth.2011.01.003 CrossRef Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kurosaka M, Kuroda R (2011) The influence of preoperative deformity on intraoperative soft tissue balance in posterior-stabilized total knee arthroplasty. J Arthroplast 26:1291–1298. doi:10.​1016/​j.​arth.​2011.​01.​003 CrossRef
4.
go back to reference Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomech Eng 128:867–871PubMedCrossRef Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomech Eng 128:867–871PubMedCrossRef
5.
go back to reference Matsumoto T, Kubo S, Muratsu H, Matsushita T, Ishida K, Kawakami Y, Oka S, Matsuzaki T, Kuroda Y, Nishida K, Akisue T, Kuroda R, Kurosaka M (2013) Different pattern in gap balancing between the cruciate-retaining and posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21:2338–2345. doi:10.1007/s00167-013-2376-4 PubMedCrossRef Matsumoto T, Kubo S, Muratsu H, Matsushita T, Ishida K, Kawakami Y, Oka S, Matsuzaki T, Kuroda Y, Nishida K, Akisue T, Kuroda R, Kurosaka M (2013) Different pattern in gap balancing between the cruciate-retaining and posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21:2338–2345. doi:10.​1007/​s00167-013-2376-4 PubMedCrossRef
6.
go back to reference Matsumoto T, Mizuno K, Muratsu H, Tsumura N, Fukase N, Kubo S, Yoshiya S, Kurosaka M, Kuroda R (2007) Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 15:1013–1018PubMedCrossRef Matsumoto T, Mizuno K, Muratsu H, Tsumura N, Fukase N, Kubo S, Yoshiya S, Kurosaka M, Kuroda R (2007) Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 15:1013–1018PubMedCrossRef
7.
go back to reference Oka S, Matsumoto T, Muratsu H, Kubo S, Matsushita T, Ishida K, Kuroda R, Kurosaka M (2013) The influence of the tibial slope on intra-operative soft tissue balance in cruciate-retaining and posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc Oka S, Matsumoto T, Muratsu H, Kubo S, Matsushita T, Ishida K, Kuroda R, Kurosaka M (2013) The influence of the tibial slope on intra-operative soft tissue balance in cruciate-retaining and posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc
9.
go back to reference Sasanuma H, Sekiya H, Takatoku K, Takada H, Sugimoto N (2010) Evaluation of soft-tissue balance during total knee arthroplasty. J Orthop Surg 18:26–30 Sasanuma H, Sekiya H, Takatoku K, Takada H, Sugimoto N (2010) Evaluation of soft-tissue balance during total knee arthroplasty. J Orthop Surg 18:26–30
11.
go back to reference Yagishita K, Muneta T, Ikeda H (2003) Step-by-step measurements of soft tissue balancing during total knee arthroplasty for patients with varus knees. J Arthroplast 18:313–320CrossRef Yagishita K, Muneta T, Ikeda H (2003) Step-by-step measurements of soft tissue balancing during total knee arthroplasty for patients with varus knees. J Arthroplast 18:313–320CrossRef
12.
go back to reference Yoshino N, Watanabe N, Watanabe Y, Fukuda Y, Takai S (2009) Measurement of joint gap load in patella everted and reset position during total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:484–490. doi:10.1007/s00167-008-0656-1 PubMedCrossRef Yoshino N, Watanabe N, Watanabe Y, Fukuda Y, Takai S (2009) Measurement of joint gap load in patella everted and reset position during total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:484–490. doi:10.​1007/​s00167-008-0656-1 PubMedCrossRef
13.
go back to reference Bellemans J, Hooghe PD, Vandenneucker H, Damme GV, Victor J (2006) Soft tissue balance in total knee arthroplasty. Clin Orthop Relat Res 452:49–52PubMedCrossRef Bellemans J, Hooghe PD, Vandenneucker H, Damme GV, Victor J (2006) Soft tissue balance in total knee arthroplasty. Clin Orthop Relat Res 452:49–52PubMedCrossRef
14.
go back to reference Niki Y, Takeda Y, Kanagawa H, Iwamoto W, Matsumoto H, Enomoto H, Toyama Y, Suda Y (2012) Effects of four different surgical approaches on intra-operative joint gap in posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:2026–2031PubMedCrossRef Niki Y, Takeda Y, Kanagawa H, Iwamoto W, Matsumoto H, Enomoto H, Toyama Y, Suda Y (2012) Effects of four different surgical approaches on intra-operative joint gap in posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:2026–2031PubMedCrossRef
15.
go back to reference Kamei G, Murakami Y, Kazusa H, Hachisuka S, Inoue H, Nobutou H, Nishida K, Mochizuki Y, Ochi M (2011) Is patella eversion during total knee arthroplasty crucial for gap adjustment and soft-tissue balancing? Orthop Traumatol Surg Res 97:287–291. doi:10.1016/j.otsr.2011.01.004 PubMedCrossRef Kamei G, Murakami Y, Kazusa H, Hachisuka S, Inoue H, Nobutou H, Nishida K, Mochizuki Y, Ochi M (2011) Is patella eversion during total knee arthroplasty crucial for gap adjustment and soft-tissue balancing? Orthop Traumatol Surg Res 97:287–291. doi:10.​1016/​j.​otsr.​2011.​01.​004 PubMedCrossRef
Metadata
Title
Gap measurement in posterior-stabilized total knee arthroplasty with or without a trial femoral component
Authors
Seiju Hayashi
Yuji Murakami
Hiroyuki Inoue
Hiroo Nobutou
Koji Nishida
Yu Mochizuki
Publication date
01-06-2014
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 6/2014
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-014-1955-2

Other articles of this Issue 6/2014

Archives of Orthopaedic and Trauma Surgery 6/2014 Go to the issue