Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 10/2022

Open Access 08-04-2021 | Foot Surgery | Orthopaedic Surgery

The application of an allogeneic bone screw for osteosynthesis in hand and foot surgery: a case series

Authors: Klaus Pastl, Wolfgang Schimetta

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 10/2022

Login to get access

Abstract

Introduction

The allogeneic bone screw transplant is a new osteosynthesis device making the use of foreign fixation material obsolete for various kinds of indications. Moreover, it is integrated into the recipient bone by natural bone remodeling without harming the surrounding tissue. The aim of this study was to determine the efficacy and safety of the transplant for osteotomy and arthrodesis in hand and foot surgery and to evaluate the clinical importance of the device.

Materials and methods

A single-surgeon case series of 32 patients who had undergone hand or foot surgery with the application of an allogeneic bone screw with an average follow-up time of 1 year is reported. Clinical data were reviewed to evaluate the pain levels and satisfaction of the patients and the frequency and type of complications occurring during the healing process. Routine radiography and computed tomography were reviewed to determine the fusion rate, the ingrowth behavior of the transplant and the possible occurrence of transplant failure.

Results

High patient satisfaction was paired with low postoperative pain levels and a low complication rate. 97% of the patients were free of pain at the timepoint of the second follow-up examination, the mean time of recovery of full mobility was 50.1 ± 26.1 days after surgery. Wound healing disturbance occurred only in two cases. Bony consolidation of the osteotomy or arthrodesis gap as well as osseointegration of the transplant was seen in all cases. No transplant failure or transplant loosening occurred.

Conclusions

The application of the allogeneic bone screw resulted in a 100% fusion rate while the patient burden was low. The transplant is safe and suited for various kinds of osteosynthesis in hand and foot surgery.
Literature
1.
go back to reference Goldberg VM, Akhavan S (2005) Biology of bone grafts. In: Lieberman JR, Friedlaender GE (eds) Bone regeneration and repair. Humana Press, Totowa, NJ, pp 57–65CrossRef Goldberg VM, Akhavan S (2005) Biology of bone grafts. In: Lieberman JR, Friedlaender GE (eds) Bone regeneration and repair. Humana Press, Totowa, NJ, pp 57–65CrossRef
3.
go back to reference Khan SN, Cammisa FP, Sandhu HS et al (2005) The biology of bone grafting. J Am Acad Orthop Surg 13:77–86CrossRef Khan SN, Cammisa FP, Sandhu HS et al (2005) The biology of bone grafting. J Am Acad Orthop Surg 13:77–86CrossRef
5.
go back to reference Barbeck M, Donkiewicz P, Blume O et al (2017) Allogene Knochenersatzmaterialien. Implantol J 7:20–24 Barbeck M, Donkiewicz P, Blume O et al (2017) Allogene Knochenersatzmaterialien. Implantol J 7:20–24
8.
go back to reference Schwier V (1957) Osteosynthese mit Corticalisschrauben. Monatsschr Unfallheilkd Versicherungsmed 60:109–112PubMed Schwier V (1957) Osteosynthese mit Corticalisschrauben. Monatsschr Unfallheilkd Versicherungsmed 60:109–112PubMed
9.
go back to reference Zaborszky Z (1967) Use of homeoplastic bone screw in the treatment of pseudarthroses. Symposia Biologica Hungarica 8:323–328 Zaborszky Z (1967) Use of homeoplastic bone screw in the treatment of pseudarthroses. Symposia Biologica Hungarica 8:323–328
10.
go back to reference Hommel HJ (1967) Bones as osteosynthesis material. Beitr Orthop Traumatol 14:571–574PubMed Hommel HJ (1967) Bones as osteosynthesis material. Beitr Orthop Traumatol 14:571–574PubMed
11.
go back to reference Grasser H (1968) Osteosynthesis with bone screws. Dtsch Zahnarztl Z 23:313–320PubMed Grasser H (1968) Osteosynthesis with bone screws. Dtsch Zahnarztl Z 23:313–320PubMed
14.
go back to reference Böhler N, Obwegeser JA, Pastl K (1997) Clinical results with screws made by homologous bone as a resorbable implant for the fixation of osteochondral fragments. JATROS Orthopädie & Traumatologie Rheumatologie 56:168 Böhler N, Obwegeser JA, Pastl K (1997) Clinical results with screws made by homologous bone as a resorbable implant for the fixation of osteochondral fragments. JATROS Orthopädie & Traumatologie Rheumatologie 56:168
15.
go back to reference Böhler N, Obwegeser J, Pastl K (1997) Die Anwendung homologer Knochenschrauben bei osteochondralen Defekten. Kongressband DGOT Böhler N, Obwegeser J, Pastl K (1997) Die Anwendung homologer Knochenschrauben bei osteochondralen Defekten. Kongressband DGOT
21.
go back to reference Hayes MHS, Patterson DG (1921) Experimental development of the graphic rating method. Psychological Bulletin 5:98–99 Hayes MHS, Patterson DG (1921) Experimental development of the graphic rating method. Psychological Bulletin 5:98–99
29.
go back to reference Rutkow IM (1986) Orthopaedic operations in the United States, 1979 through 1983. J Bone Joint Surg Am 68:716–719CrossRef Rutkow IM (1986) Orthopaedic operations in the United States, 1979 through 1983. J Bone Joint Surg Am 68:716–719CrossRef
31.
go back to reference Cochran G van B (1988) Orthopädische Biomechanik. Ferdinand Enke Verlag Stuttgart Cochran G van B (1988) Orthopädische Biomechanik. Ferdinand Enke Verlag Stuttgart
32.
go back to reference Pilz W, Blankenburg G (1997) Mechanische Kennwerte von Knochenersatzwerkstoffen unter Berücksichtigung verschiedener Entnahmeparameter. Knochenersatzmaterialien und Wachstumsfaktoren 58:162–170 Pilz W, Blankenburg G (1997) Mechanische Kennwerte von Knochenersatzwerkstoffen unter Berücksichtigung verschiedener Entnahmeparameter. Knochenersatzmaterialien und Wachstumsfaktoren 58:162–170
33.
go back to reference Ungethuem M, Winkler-Gniewerk W (1984) Metallische Werkstoffe in der Orthopädie und Unfallchirurgie. Thieme Stuttgart New York Ungethuem M, Winkler-Gniewerk W (1984) Metallische Werkstoffe in der Orthopädie und Unfallchirurgie. Thieme Stuttgart New York
34.
go back to reference Cowin SC (2001) Bone Mechanics Handbook. CRC Press Inc, Boca Raton, FL, SubsequentCrossRef Cowin SC (2001) Bone Mechanics Handbook. CRC Press Inc, Boca Raton, FL, SubsequentCrossRef
36.
go back to reference Gutwald R, Pistner H, Schwartz G, Mühling J (1995) Biodegradation of poly(L-lactide) screws in femur of guinea-pigs. Biomed Eng 40:49–50 Gutwald R, Pistner H, Schwartz G, Mühling J (1995) Biodegradation of poly(L-lactide) screws in femur of guinea-pigs. Biomed Eng 40:49–50
37.
go back to reference Weiler A, Hoffmann RF, Stähelin AC et al (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16:305–321CrossRef Weiler A, Hoffmann RF, Stähelin AC et al (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16:305–321CrossRef
43.
go back to reference Böstman OM, Pihlajamäki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthopaed Relat Res 371:216CrossRef Böstman OM, Pihlajamäki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthopaed Relat Res 371:216CrossRef
Metadata
Title
The application of an allogeneic bone screw for osteosynthesis in hand and foot surgery: a case series
Authors
Klaus Pastl
Wolfgang Schimetta
Publication date
08-04-2021
Publisher
Springer Berlin Heidelberg
Keyword
Foot Surgery
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 10/2022
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-021-03880-6

Other articles of this Issue 10/2022

Archives of Orthopaedic and Trauma Surgery 10/2022 Go to the issue