Skip to main content
Top
Published in: Neuroradiology 11/2003

01-11-2003 | Interventional Neuroradiology

Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography

Authors: J. P. Cottier, A. Bleuzen-Couthon, S. Gallas, C. B. Vinikoff-Sonier, P. Bertrand, F. Domengie, L. Barantin, D. Herbreteau

Published in: Neuroradiology | Issue 11/2003

Login to get access

Abstract

All patients with aneurysms treated with Guglielmi detachable coils (GDC) are undergo angiography to assess long-term stability of aneurysm exclusion or to show recurrence of the aneurysm sac, which may require further treatment. We prospectively compared the plain-film appearance of the coil-mass, 3D time-of-flight MR angiography (TOF MRA) and digital subtraction angiography (DSA) for the detection of aneurysm recanalisation during follow-up. We studied 60  patients with 74 intracranial aneurysms treated with Guglielmi detachable coils. We used the unsubtracted image of the angiograms performed at the completion of any embolisation procedure and at follow-up as the plain radiographs. Recanalisation was considered if loosening, compaction or reorientation of the coil mass was apparent. TOF MRA was performed to assess the presence and size of a neck remnant. DSA was regarded as the definitive investigation. Comparison of the techniques showed good agreement as regards aneurysm recanalisation. MRA was more accurate than plain radiography and could replace DSA for long term follow- up. The initial follow-up examination should, however, include both modalities. In cases of contraindications or limitations to MRA, the interval between follow-up angiographic examinations could be increased if there is no change in the plain-film coil-mass appearances.
Literature
1.
go back to reference Guglielmi G, Viñuela F, Dion J, Duckwiler G (1991) Electrothrombosis of saccular aneurysms via endovascular approach. I: preliminary clinical experience. J Neurosurg 75: 8–14PubMed Guglielmi G, Viñuela F, Dion J, Duckwiler G (1991) Electrothrombosis of saccular aneurysms via endovascular approach. I: preliminary clinical experience. J Neurosurg 75: 8–14PubMed
2.
go back to reference Derdeyn CP, Graves VB, Tursky PA, Masaryk AM, Strother CM (1997) MR angiography of saccular aneurysms after treatment with Guglielmi detachable coils: preliminary experience. AJNR 18: 279–286 Derdeyn CP, Graves VB, Tursky PA, Masaryk AM, Strother CM (1997) MR angiography of saccular aneurysms after treatment with Guglielmi detachable coils: preliminary experience. AJNR 18: 279–286
3.
go back to reference Gönner F, Heid L, Remonda G, et al (1998 ) MR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils. AJNR 19: 1324–1328 Gönner F, Heid L, Remonda G, et al (1998 ) MR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils. AJNR 19: 1324–1328
4.
go back to reference Kähära VJ, Seppänen SK, Ryymin PS, Mattila P, Kuurne T, Laasonen EM (1999) MR angiography with three-dimensional time-of-flight and targeted maximum-intensity-projection reconstructions in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils. AJNR 20: 1470 –1475 Kähära VJ, Seppänen SK, Ryymin PS, Mattila P, Kuurne T, Laasonen EM (1999) MR angiography with three-dimensional time-of-flight and targeted maximum-intensity-projection reconstructions in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils. AJNR 20: 1470 –1475
5.
go back to reference Brunereau L, Cottier JP, Sonier CB, et al (1999) Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils. J Comput Assist Tomogr 23: 216–223CrossRefPubMed Brunereau L, Cottier JP, Sonier CB, et al (1999) Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils. J Comput Assist Tomogr 23: 216–223CrossRefPubMed
6.
go back to reference Anzalone N, Righi C, Simionato F, et al (2000) Three-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils. AJNR 21: 746 –752 Anzalone N, Righi C, Simionato F, et al (2000) Three-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils. AJNR 21: 746 –752
7.
go back to reference Boulin A, Pierot L (2000) Follow-up of intracranial aneurysms treated with detachable coils: comparison of gadolinium enhanced 3D time-of-flight MR angiography and digital subtraction angiography. Radiology 219: 108–113 Boulin A, Pierot L (2000) Follow-up of intracranial aneurysms treated with detachable coils: comparison of gadolinium enhanced 3D time-of-flight MR angiography and digital subtraction angiography. Radiology 219: 108–113
8.
go back to reference Nome T, Bakke SJ, Nakstad PH (2002) MR angiography in the follow-up of coiled cerebral aneurysms after treatment with Guglielmi detachable coils. Acta Radiol 43: 10–14CrossRefPubMed Nome T, Bakke SJ, Nakstad PH (2002) MR angiography in the follow-up of coiled cerebral aneurysms after treatment with Guglielmi detachable coils. Acta Radiol 43: 10–14CrossRefPubMed
9.
go back to reference Leclerc X, Navez JF, Gauvrit JY, Lejeune JP, Pruvo JP (2001) Aneurysms of the anterior communicating artery treated with Guglielmi detachable coils: follow-up with contrast-enhanced MR angiography. AJNR 23: 112–1127 Leclerc X, Navez JF, Gauvrit JY, Lejeune JP, Pruvo JP (2001) Aneurysms of the anterior communicating artery treated with Guglielmi detachable coils: follow-up with contrast-enhanced MR angiography. AJNR 23: 112–1127
10.
go back to reference Connor SEJ, West RJ, Yates DA (2001) The ability of plain radiography to predict intracranial aneurysm occlusion instability during follow-up of endosaccular treatment with Guglielmi detachable coils. Neuroradiology 43: 680–686CrossRefPubMed Connor SEJ, West RJ, Yates DA (2001) The ability of plain radiography to predict intracranial aneurysm occlusion instability during follow-up of endosaccular treatment with Guglielmi detachable coils. Neuroradiology 43: 680–686CrossRefPubMed
11.
go back to reference Cognard C, Weill A, Spelle L, et al (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212: 348–356PubMed Cognard C, Weill A, Spelle L, et al (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212: 348–356PubMed
12.
go back to reference Viñuela F, Duckwiler G, Mawad M, Guglielmi G (1997) Detachable coil embolisation of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86: 475–482PubMed Viñuela F, Duckwiler G, Mawad M, Guglielmi G (1997) Detachable coil embolisation of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86: 475–482PubMed
13.
go back to reference Byrne JV, Sohn MJ, Molyneux AJ (1999) Five-year experience in using coil embolisation for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 90: 656–663PubMed Byrne JV, Sohn MJ, Molyneux AJ (1999) Five-year experience in using coil embolisation for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 90: 656–663PubMed
14.
go back to reference Cloft HJ, Joseph GJ, Dion JE (1999) Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation. a meta-analysis. Stroke 30: 317–320PubMed Cloft HJ, Joseph GJ, Dion JE (1999) Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation. a meta-analysis. Stroke 30: 317–320PubMed
15.
go back to reference Heiserman JE, Dean BL, Hodak JA, et al (1994) Neurologic complications of cerebral angiography. AJNR 15: 1408–1411 Heiserman JE, Dean BL, Hodak JA, et al (1994) Neurologic complications of cerebral angiography. AJNR 15: 1408–1411
16.
go back to reference Hartman J, Nguyen T, Larsen D, Teitelbaum GP (1997) MR artifacts, heat production, and ferromagnetism of Guglielmi detachable coils: preliminary experience. AJNR 18: 279–286 Hartman J, Nguyen T, Larsen D, Teitelbaum GP (1997) MR artifacts, heat production, and ferromagnetism of Guglielmi detachable coils: preliminary experience. AJNR 18: 279–286
17.
go back to reference Piotin M, Mandai S, Murphy KJ, et al (2000) Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils. AJNR 21: 757–760 Piotin M, Mandai S, Murphy KJ, et al (2000) Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils. AJNR 21: 757–760
18.
go back to reference Reul J, Spetzger U, Weis J, Sure U, Gilsbach JM, Thron A (1997) Endovascular occlusion of experimental aneurysms with detachable coils: influence of packing density and perioperative anticoagulation. Neurosurgery 41: 1160–1165PubMed Reul J, Spetzger U, Weis J, Sure U, Gilsbach JM, Thron A (1997) Endovascular occlusion of experimental aneurysms with detachable coils: influence of packing density and perioperative anticoagulation. Neurosurgery 41: 1160–1165PubMed
19.
go back to reference Byrne JV, Hope JKA, Hubbard N, Morris JH (1997) The nature of thrombosis induced by platinum and tungsten coils in saccular aneurysms. AJNR 18: 29–33 Byrne JV, Hope JKA, Hubbard N, Morris JH (1997) The nature of thrombosis induced by platinum and tungsten coils in saccular aneurysms. AJNR 18: 29–33
20.
go back to reference Cognard C, Weill A, Castaing L, et al (1998) Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. Radiology 206: 499–510PubMed Cognard C, Weill A, Castaing L, et al (1998) Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. Radiology 206: 499–510PubMed
21.
go back to reference Feuerberg I, Lindquist C, Lindqvist M, et al (1987) Natural history of postoperative aneurysm rests. J Neurosurg 66: 30–34PubMed Feuerberg I, Lindquist C, Lindqvist M, et al (1987) Natural history of postoperative aneurysm rests. J Neurosurg 66: 30–34PubMed
Metadata
Title
Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography
Authors
J. P. Cottier
A. Bleuzen-Couthon
S. Gallas
C. B. Vinikoff-Sonier
P. Bertrand
F. Domengie
L. Barantin
D. Herbreteau
Publication date
01-11-2003
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 11/2003
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-003-1109-7

Other articles of this Issue 11/2003

Neuroradiology 11/2003 Go to the issue