Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 3/2019

01-03-2019 | Handsurgery

Flexor tendon repair with a polytetrafluoroethylene (PTFE) suture material

Authors: Elias Polykandriotis, Foued Besrour, Andreas Arkudas, Florian Ruppe, Katharina Zetzmann, Lars Braeuer, Raymund E. Horch

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 3/2019

Login to get access

Abstract

Background

There is a consensus that after a flexor tendon repair an aggressive rehabilitation protocol with early active motion can improve functional outcome, provided that the combination of material and suturing technique can meet the higher biomechanic demands. Bearing this in mind we evaluated a polytetrafluoroethylene (PTFE) suture (SERAMON®, Serag-Wiessner) as a possible material for flexor tendon repair.

Materials and methods

40 flexor tendons were harvested from fresh cadaveric upper extremities. 3–0 and 5–0 strands were used both in the polypropylene (PPL) as well as in the PTFE group. In the first phase of the study, we evaluated knotting properties and mechanical characteristics of the suture materials themselves. In the second phase, a 2-strand Kirchmayr–Kessler suture technique was applied for a core suture of a flexor tendon (n = 16). In the third phase, we performed a tendon repair including an epitendinous running suture with 5–0 PPL or 5–0 PTFE material (n = 22). One way ANOVA tests were performed.

Results

The linear loading strength of single strand knotted PPL 3–0 was 19.87 ± 0.59 N. The linear loading strength of knotted PTFE 3–0 was 32.47 ± 1.67 N. For PPL 3–0 maximum linear strength was achieved with five knots, for PTFE 3–0 with eight knots. When a Kirchmayr–Kessler core-only repair was performed, then in the PPL group the loading strength of the repaired tendon was 30.74 ± 9.77 N. In the PTFE group the loading strength was 23.74 ± 5.6 N (p = 0.10). However, all repairs in the PTFE group failed due to cheese wiring. When a Kirchmayr–Kessler core and epitendinous repair technique was used, then in the PPL group the loading strength of the repaired tendon was 49.90 ± 16.05 N. In the PTFE group the loading strength was 73.41 ± 19.81 N (p = 0.006).

Conclusion

PTFE demonstrates superior strength properties in comparison to PPL for flexor tendon repairs. However, standard 2 strand techniques have proved inadequate to bear the higher biomechanic demands.
Literature
1.
go back to reference Abellan D, Nart J, Pascual A, Cohen RE, Sanz-Moliner JD (2016) Physical and mechanical evaluation of five suture materials on three knot configurations: an in vitro study. Polym Basel 8(4):47–156 Abellan D, Nart J, Pascual A, Cohen RE, Sanz-Moliner JD (2016) Physical and mechanical evaluation of five suture materials on three knot configurations: an in vitro study. Polym Basel 8(4):47–156
2.
go back to reference Beimers L, Lam PH, Murrell GA (2014) The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model. J Shoulder Elbow Surg 23(10):1545–1552CrossRefPubMed Beimers L, Lam PH, Murrell GA (2014) The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model. J Shoulder Elbow Surg 23(10):1545–1552CrossRefPubMed
3.
go back to reference Caimmi PP, Sabbatini M, Fusaro L, Borrone A, Cannas M (2016) A study of the mechanical properties of ePTFE suture used as artificial mitral chordae. J Card Surg 31(8):498–502CrossRefPubMed Caimmi PP, Sabbatini M, Fusaro L, Borrone A, Cannas M (2016) A study of the mechanical properties of ePTFE suture used as artificial mitral chordae. J Card Surg 31(8):498–502CrossRefPubMed
4.
go back to reference Chen J, Zhou X (2018) Letter to editor: the impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair. Arch Orthop Trauma Surg 138(7):1035–1036CrossRefPubMed Chen J, Zhou X (2018) Letter to editor: the impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair. Arch Orthop Trauma Surg 138(7):1035–1036CrossRefPubMed
5.
go back to reference Edsfeldt S, Rempel D, Kursa K, Diao E, Lattanza L (2015) In vivo flexor tendon forces generated during different rehabilitation exercises. J Hand Surg Eur Vol 40(7):705–710CrossRefPubMed Edsfeldt S, Rempel D, Kursa K, Diao E, Lattanza L (2015) In vivo flexor tendon forces generated during different rehabilitation exercises. J Hand Surg Eur Vol 40(7):705–710CrossRefPubMed
6.
go back to reference Franco J, Kelly E, Kelly M (2014) Periareolar augmentation mastopexy with interlocking gore-tex suture, retrospective review of 50 consecutive patients. Arch Plast Surg 41(6):728–733CrossRefPubMedPubMedCentral Franco J, Kelly E, Kelly M (2014) Periareolar augmentation mastopexy with interlocking gore-tex suture, retrospective review of 50 consecutive patients. Arch Plast Surg 41(6):728–733CrossRefPubMedPubMedCentral
7.
go back to reference Gill RS, Lim BH, Shatford RA, Toth E, Voor MJ, Tsai TM (1999) A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: a human cadaveric study. J Hand Surg 24(6):1315–1322CrossRef Gill RS, Lim BH, Shatford RA, Toth E, Voor MJ, Tsai TM (1999) A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: a human cadaveric study. J Hand Surg 24(6):1315–1322CrossRef
8.
go back to reference Gonzalez-Barnadas A, Camps-Font O, Espanya-Grifoll D, Espana-Tost A, Figueiredo R, Valmaseda-Castellon E (2017) In Vitro tensile strength study on suturing technique and material. J Oral Implantol 43(3):169–174CrossRefPubMed Gonzalez-Barnadas A, Camps-Font O, Espanya-Grifoll D, Espana-Tost A, Figueiredo R, Valmaseda-Castellon E (2017) In Vitro tensile strength study on suturing technique and material. J Oral Implantol 43(3):169–174CrossRefPubMed
9.
go back to reference Leppanen OV, Linnanmaki L, Havulinna J, Goransson H (2016) Suture configurations and biomechanical properties of flexor tendon repairs by 16 hand surgeons in Finland. J Hand Surg Eur Vol 41(8):831–837CrossRefPubMed Leppanen OV, Linnanmaki L, Havulinna J, Goransson H (2016) Suture configurations and biomechanical properties of flexor tendon repairs by 16 hand surgeons in Finland. J Hand Surg Eur Vol 41(8):831–837CrossRefPubMed
11.
go back to reference Newmeyer WLrd, Manske PR (2004) No man’s land revisited: the primary flexor tendon repair controversy. J Hand Surg 29(1):1–5CrossRef Newmeyer WLrd, Manske PR (2004) No man’s land revisited: the primary flexor tendon repair controversy. J Hand Surg 29(1):1–5CrossRef
12.
go back to reference Olivier LC, Assenmacher S, Kendoff D, Schmidt G, Towfigh H, Schmit-Neuerburg KP (2001) Results of flexor tendon repair of the hand by the motion-stable wire suture by Towfigh. Arch Orthop Trauma Surg 121(4):212–218CrossRefPubMed Olivier LC, Assenmacher S, Kendoff D, Schmidt G, Towfigh H, Schmit-Neuerburg KP (2001) Results of flexor tendon repair of the hand by the motion-stable wire suture by Towfigh. Arch Orthop Trauma Surg 121(4):212–218CrossRefPubMed
13.
go back to reference Quadlbauer S, Pezzei C, Jurkowitsch J, Reb P, Beer T, Leixnering M (2016) Early passive movement in flexor tendon injuries of the hand. Arch Orthop Trauma Surg 136(2):285–293CrossRefPubMed Quadlbauer S, Pezzei C, Jurkowitsch J, Reb P, Beer T, Leixnering M (2016) Early passive movement in flexor tendon injuries of the hand. Arch Orthop Trauma Surg 136(2):285–293CrossRefPubMed
14.
go back to reference Savage R, Tang JB (2016) History and nomenclature of multistrand repairs in digital flexor tendons. J Hand Surg 41(2):291–293CrossRef Savage R, Tang JB (2016) History and nomenclature of multistrand repairs in digital flexor tendons. J Hand Surg 41(2):291–293CrossRef
15.
go back to reference Schuind F, Garcia-Elias M, Cooney WPrd, An KN (1992) Flexor tendon forces: in vivo measurements. J Hand Surg 17(2):291–298CrossRef Schuind F, Garcia-Elias M, Cooney WPrd, An KN (1992) Flexor tendon forces: in vivo measurements. J Hand Surg 17(2):291–298CrossRef
16.
go back to reference Tang JB (2018) New developments are improving flexor tendon repair. Plast Reconstr Surg 141(6):1427–1437CrossRefPubMed Tang JB (2018) New developments are improving flexor tendon repair. Plast Reconstr Surg 141(6):1427–1437CrossRefPubMed
17.
go back to reference Tang JB (2018) Recent evolutions in flexor tendon repairs and rehabilitation. J Hand Surg Eur Vol 43(5):469–473CrossRefPubMed Tang JB (2018) Recent evolutions in flexor tendon repairs and rehabilitation. J Hand Surg Eur Vol 43(5):469–473CrossRefPubMed
18.
go back to reference Tang JB, Zhou X, Pan ZJ, Qing J, Gong KT, Chen J (2017) Strong digital flexor tendon repair, extension-flexion test, and early active flexion: experience in 300 tendons. Hand Clin 33(3):455–463CrossRefPubMed Tang JB, Zhou X, Pan ZJ, Qing J, Gong KT, Chen J (2017) Strong digital flexor tendon repair, extension-flexion test, and early active flexion: experience in 300 tendons. Hand Clin 33(3):455–463CrossRefPubMed
19.
go back to reference Tolerton SK, Lawson RD, Tonkin MA (2014) Management of flexor tendon injuries—part 2: current practice in Australia and guidelines for training young surgeons. Hand Surg Int J Devoted Hand Up Limb Surg Relat Res J Asia Pac Fed Soc Surg Hand 19(2):305–310 Tolerton SK, Lawson RD, Tonkin MA (2014) Management of flexor tendon injuries—part 2: current practice in Australia and guidelines for training young surgeons. Hand Surg Int J Devoted Hand Up Limb Surg Relat Res J Asia Pac Fed Soc Surg Hand 19(2):305–310
20.
go back to reference Waitayawinyu T, Martineau PA, Luria S, Hanel DP, Trumble TE (2008) Comparative biomechanic study of flexor tendon repair using FiberWire. J Hand Surg 33(5):701–708CrossRef Waitayawinyu T, Martineau PA, Luria S, Hanel DP, Trumble TE (2008) Comparative biomechanic study of flexor tendon repair using FiberWire. J Hand Surg 33(5):701–708CrossRef
21.
go back to reference Wieskotter B, Herbort M, Langer M, Raschke MJ, Wahnert D (2018) The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair. Arch Orthop Trauma Surg 138(1):139–145CrossRefPubMed Wieskotter B, Herbort M, Langer M, Raschke MJ, Wahnert D (2018) The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair. Arch Orthop Trauma Surg 138(1):139–145CrossRefPubMed
Metadata
Title
Flexor tendon repair with a polytetrafluoroethylene (PTFE) suture material
Authors
Elias Polykandriotis
Foued Besrour
Andreas Arkudas
Florian Ruppe
Katharina Zetzmann
Lars Braeuer
Raymund E. Horch
Publication date
01-03-2019
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 3/2019
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-018-03105-3

Other articles of this Issue 3/2019

Archives of Orthopaedic and Trauma Surgery 3/2019 Go to the issue