Skip to main content
Top
Published in: Trials 1/2024

Open Access 01-12-2024 | Study protocol

Flexor Injury Rehabilitation Splint Trial (FIRST): protocol for a pragmatic randomised controlled trial comparing three splints for finger flexor tendon repairs

Authors: Emma Bamford, Hannah Berntsson, Suzanne Beale, Lauren Desoysa, Joseph Dias, Sienna Hamer-Kiwacz, Daniel Hind, Nick Johnson, Amanda Loban, Kaye Molloy, Emma Morvan, Ines Rombach, Anna Selby, Praveen Thokala, Chris Turtle, Stephen Walters, Avril Drummond

Published in: Trials | Issue 1/2024

Login to get access

Abstract

Background

Without surgical repair, flexor tendon injuries do not heal and patients’ ability to bend fingers and grip objects is impaired. However, flexor tendon repair surgery also requires optimal rehabilitation. There are currently three custom-made splints used in the rehabilitation of zone I/II flexor tendon repairs, each with different assumed harm/benefit profiles: the dorsal forearm and hand-based splint (long), the Manchester short splint (short), and the relative motion flexion splint (mini). There is, however, no robust evidence as to which splint, if any, is most clinical or cost effective. The Flexor Injury Rehabilitation Splint Trial (FIRST) was designed to address this evidence gap.

Methods

FIRST is a parallel group, superiority, analyst-blind, multi-centre, individual participant-randomised controlled trial. Participants will be assigned 1:1:1 to receive either the long, short, or mini splint. We aim to recruit 429 participants undergoing rehabilitation following zone I/II flexor tendon repair surgery. Potential participants will initially be identified prior to surgery, in NHS hand clinics across the UK, and consented and randomised at their splint fitting appointment post-surgery. The primary outcome will be the mean post-randomisation score on the patient-reported wrist and hand evaluation measure (PRWHE), assessed at 6, 12, 26, and 52 weeks post randomisation. Secondary outcome measures include blinded grip strength and active range of movement (AROM) assessments, adverse events, adherence to the splinting protocol (measured via temperature sensors inserted into the splints), quality of life assessment, and further patient-reported outcomes. An economic evaluation will assess the cost-effectiveness of each splint, and a qualitative sub-study will evaluate participants’ preferences for, and experiences of wearing, the splints. Furthermore, a mediation analysis will determine the relationship between patient preferences, splint adherence, and splint effectiveness.

Discussion

FIRST will compare the three splints with respect to clinical efficacy, complications, quality of life and cost-effectiveness. FIRST is a pragmatic trial which will recruit from 26 NHS sites to allow findings to be generalisable to current clinical practice in the UK. It will also provide significant insights into patient experiences of splint wear and how adherence to splinting may impact outcomes.

Trial registration

ISRCTN: 10236011
Appendix
Available only for authorised users
Literature
1.
go back to reference Robinson LS, Sarkies M, Brown T, O’Brien L. Direct, indirect and intangible costs of acute hand and wrist injuries: a systematic review. Injury. 2016;47(12):2614–26.CrossRefPubMed Robinson LS, Sarkies M, Brown T, O’Brien L. Direct, indirect and intangible costs of acute hand and wrist injuries: a systematic review. Injury. 2016;47(12):2614–26.CrossRefPubMed
3.
go back to reference Gustafsson M, Hagberg L, Holmefur M. Ten years follow-up of health and disability in people with acute traumatic hand injury: pain and cold sensitivity are long-standing problems. J Hand Surg Eur. 2011;36(7):590–8.CrossRef Gustafsson M, Hagberg L, Holmefur M. Ten years follow-up of health and disability in people with acute traumatic hand injury: pain and cold sensitivity are long-standing problems. J Hand Surg Eur. 2011;36(7):590–8.CrossRef
4.
go back to reference Deniz E, Ayse K, Sehim K, Mehmet D, Aysun S, Süreyya E. Postoperative management of flexor tendon repair in zone 2. J Phys Ther Sci. 2000;12(1):63–6.CrossRef Deniz E, Ayse K, Sehim K, Mehmet D, Aysun S, Süreyya E. Postoperative management of flexor tendon repair in zone 2. J Phys Ther Sci. 2000;12(1):63–6.CrossRef
5.
go back to reference May EJ, Silfverskiöld KL. Rate of recovery after flexor tendon repair in zone II a prospective longitudinal study of 145 digits. Scand J Plast Reconstr Surg Hand Surg. 1993;27(2):89–94.CrossRefPubMed May EJ, Silfverskiöld KL. Rate of recovery after flexor tendon repair in zone II a prospective longitudinal study of 145 digits. Scand J Plast Reconstr Surg Hand Surg. 1993;27(2):89–94.CrossRefPubMed
6.
go back to reference Peters SE, Jha B, Ross M. Rehabilitation following surgery for flexor tendon injuries of the hand. Cochrane Database Syst Rev. 2021;1(1) Peters SE, Jha B, Ross M. Rehabilitation following surgery for flexor tendon injuries of the hand. Cochrane Database Syst Rev. 2021;1(1)
7.
go back to reference Peck FH, Roe AE, Ng CY, Duff C, McGrouther DA, Lees VC. The Manchester short splint: a change to splinting practice in the rehabilitation of zone II flexor tendon repairs. Hand Ther. 2014;19(2):47–53.CrossRef Peck FH, Roe AE, Ng CY, Duff C, McGrouther DA, Lees VC. The Manchester short splint: a change to splinting practice in the rehabilitation of zone II flexor tendon repairs. Hand Ther. 2014;19(2):47–53.CrossRef
8.
go back to reference Hirth MJ, Howell JW, Feehan LM, Brown T, O’Brien L. Postoperative hand therapy management of zones V and VI extensor tendon repairs of the fingers: an international inquiry of current practice. J Hand Ther. 2021;34(1):58–75.CrossRefPubMed Hirth MJ, Howell JW, Feehan LM, Brown T, O’Brien L. Postoperative hand therapy management of zones V and VI extensor tendon repairs of the fingers: an international inquiry of current practice. J Hand Ther. 2021;34(1):58–75.CrossRefPubMed
10.
go back to reference Dias JJ, Bhowal B, Wildin CJ, Thompson JR. Assessing the outcome of disorders of the hand. Is the patient evaluation measure reliable, valid, responsive and without bias? J Bone Joint Surg Br. 2001;83(2):235–40.CrossRefPubMed Dias JJ, Bhowal B, Wildin CJ, Thompson JR. Assessing the outcome of disorders of the hand. Is the patient evaluation measure reliable, valid, responsive and without bias? J Bone Joint Surg Br. 2001;83(2):235–40.CrossRefPubMed
11.
go back to reference Reilly MC, DE ZAS. The validity and reproducibility of a work productivity and activity impairment instrument. Pharmacoeconomics. 1993;4(5):353–65.CrossRefPubMed Reilly MC, DE ZAS. The validity and reproducibility of a work productivity and activity impairment instrument. Pharmacoeconomics. 1993;4(5):353–65.CrossRefPubMed
12.
go back to reference The EuroQol Group. EuroQol-a new facility for the measurement of health-related quality of life. Health Policy. 1990;16(3):199–208.CrossRef The EuroQol Group. EuroQol-a new facility for the measurement of health-related quality of life. Health Policy. 1990;16(3):199–208.CrossRef
13.
go back to reference Jaeschke R, Singer JGG. Measurement of health status. Ascertaining the minimal clinically important difference. Control Clin Trials. 1989;10(4):407–15.CrossRefPubMed Jaeschke R, Singer JGG. Measurement of health status. Ascertaining the minimal clinically important difference. Control Clin Trials. 1989;10(4):407–15.CrossRefPubMed
14.
go back to reference Jansen CWWM. Measurement of range of motion of the finger after flexor tendon repair in zone II of the hand. J Hand Surg Am. 1993;18(3):411–7.CrossRefPubMed Jansen CWWM. Measurement of range of motion of the finger after flexor tendon repair in zone II of the hand. J Hand Surg Am. 1993;18(3):411–7.CrossRefPubMed
15.
go back to reference Mace M, Mutalib SA, Ogrinc M, Goldsmith N, Burdet E. GripAble: An accurate, sensitive and robust digital device for measuring grip strength. J Rehabil Assist Technol Eng. 2022;9:205566832210784. Mace M, Mutalib SA, Ogrinc M, Goldsmith N, Burdet E. GripAble: An accurate, sensitive and robust digital device for measuring grip strength. J Rehabil Assist Technol Eng. 2022;9:205566832210784.
16.
go back to reference Machin D, Campbell MJ, Tan SBTS. Repeated outcome measures. sample sizes for clinical, laboratory and epidemiology studies. USA: John Wiley & Sons; 2018.CrossRef Machin D, Campbell MJ, Tan SBTS. Repeated outcome measures. sample sizes for clinical, laboratory and epidemiology studies. USA: John Wiley & Sons; 2018.CrossRef
17.
go back to reference Dias J, Brealey S, Choudhary S, Cook L, Costa M, Fairhurst C, et al. Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) protocol: a pragmatic multi-centre randomised controlled trial of cast treatment versus surgical fixation for the treatment of bi-cortical, minimally displaced fractures of the scaphoid waist i. BMC Musculoskelet Disord. 2016;17(1):1–15. https://doi.org/10.1186/s12891-016-1107-7.CrossRef Dias J, Brealey S, Choudhary S, Cook L, Costa M, Fairhurst C, et al. Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) protocol: a pragmatic multi-centre randomised controlled trial of cast treatment versus surgical fixation for the treatment of bi-cortical, minimally displaced fractures of the scaphoid waist i. BMC Musculoskelet Disord. 2016;17(1):1–15. https://​doi.​org/​10.​1186/​s12891-016-1107-7.CrossRef
18.
go back to reference Dias JJ, Brealey SD, Fairhurst C, Amirfeyz R, Bhowal B, Blewitt N, et al. Surgery versus cast immobilisation for adults with a bicortical fracture of the scaphoid waist (SWIFFT): a pragmatic, multicentre, open-label, randomised superiority trial. Lancet. 2020;396(10248):390–401.CrossRefPubMed Dias JJ, Brealey SD, Fairhurst C, Amirfeyz R, Bhowal B, Blewitt N, et al. Surgery versus cast immobilisation for adults with a bicortical fracture of the scaphoid waist (SWIFFT): a pragmatic, multicentre, open-label, randomised superiority trial. Lancet. 2020;396(10248):390–401.CrossRefPubMed
19.
go back to reference Schulz KF, Altman DG, Moher D. CONSORT 2010 statement: updated guidelines for reporting parallel group randomized trials. Obstet Gynecol. 2010;115(5):1063–70.CrossRefPubMed Schulz KF, Altman DG, Moher D. CONSORT 2010 statement: updated guidelines for reporting parallel group randomized trials. Obstet Gynecol. 2010;115(5):1063–70.CrossRefPubMed
20.
go back to reference Walters SJ. Quality of life outcomes in clinical trials and health-care evaluation. a practical guide to analysis and interpretation. 1st ed. USA: John Wiley & Sons Ltd; 2009.CrossRef Walters SJ. Quality of life outcomes in clinical trials and health-care evaluation. a practical guide to analysis and interpretation. 1st ed. USA: John Wiley & Sons Ltd; 2009.CrossRef
21.
go back to reference Moore GF, Audrey S, Barker M, Bond L, Bonell C, Hardeman W, et al. Process evaluation of complex interventions: Medical Research Council guidance. BMJ. 2015;350 Moore GF, Audrey S, Barker M, Bond L, Bonell C, Hardeman W, et al. Process evaluation of complex interventions: Medical Research Council guidance. BMJ. 2015;350
Metadata
Title
Flexor Injury Rehabilitation Splint Trial (FIRST): protocol for a pragmatic randomised controlled trial comparing three splints for finger flexor tendon repairs
Authors
Emma Bamford
Hannah Berntsson
Suzanne Beale
Lauren Desoysa
Joseph Dias
Sienna Hamer-Kiwacz
Daniel Hind
Nick Johnson
Amanda Loban
Kaye Molloy
Emma Morvan
Ines Rombach
Anna Selby
Praveen Thokala
Chris Turtle
Stephen Walters
Avril Drummond
Publication date
01-12-2024
Publisher
BioMed Central
Published in
Trials / Issue 1/2024
Electronic ISSN: 1745-6215
DOI
https://doi.org/10.1186/s13063-024-08013-z

Other articles of this Issue 1/2024

Trials 1/2024 Go to the issue