Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2022

Open Access 01-12-2022 | Research

Finite element analysis of intraosseous distal radioulnar joint prosthesis

Authors: Farzaneh Gholamian, Mehran Ashrafi, Ali Moradi

Published in: BMC Musculoskeletal Disorders | Issue 1/2022

Login to get access

Abstract

Background

Joint replacement is one of the options to retrieve the interosseous distal radioulnar joint (DRUJ) function. DRUJ prosthesis has recently been introduced clinically to treat DRUJ instability. This article analyzes the biomechanical behavior of the prosthesis during different loadings by the finite element method.

Methods

CT images of a healthy 33 years old man were used to construct the three-dimensional geometry of the forearm bone. Then two models, a healthy foreman (Model A) and a damaged model with an inserted interosseous prosthesis (Model B), were constructed to analyze and compare the foreman's biomechanical behavior under different loading conditions using the finite element method. Both models were examined during pronation and supination with 500, 1000, 2000, and 5000 N.mm values. Also, both models were subjected to volar and dorsal loads with values of 10, 30, and 50 N and traction force with 100, 150, and 200 N.

Results

Maximum and minimum principal stresses were evaluated for bones in all conditions, and von Mises stress was considered for the prosthesis and fixing screws. In supination, the maximum stress in Model A is significantly higher than the Model B. However, the maximum principal stress of both models is similar during volar and dorsal loading. In Model A, the maximum principal stress in traction is much smaller than in Model B. The absolute value of minimum principal stress in pronation and supination in Model B is higher than in Model A. The prostheses and screws are subjected to higher stresses during pronation than supination. Also, the amount of stress created in prostheses and screws during volar and dorsal loading is almost equal. In traction loading, screws are subjected to significantly high stresses.

Conclusion

Our study indicates that the interosseous DRUJ prosthesis can perform the foreman's normal daily activities. This prosthesis provides the ability similar to a normal hand.

Level of evidence

IV.
Literature
1.
go back to reference Fuchs N, Meier L, Giesen T, Calcagni M, Reissner L. Long-term results after semiconstrained distal radioulnar joint arthroplasty: A focus on complications. Hand Surg Rehabil. 2020;39(3):186–92.CrossRef Fuchs N, Meier L, Giesen T, Calcagni M, Reissner L. Long-term results after semiconstrained distal radioulnar joint arthroplasty: A focus on complications. Hand Surg Rehabil. 2020;39(3):186–92.CrossRef
2.
go back to reference Thomas BP, Sreekanth R. Distal radioulnar joint injuries. Indian J Orthop. 2012;46(5):493–504.CrossRef Thomas BP, Sreekanth R. Distal radioulnar joint injuries. Indian J Orthop. 2012;46(5):493–504.CrossRef
3.
go back to reference Austman RL, King GJ, Dunning CE. Bone stresses before and after insertion of two commercially available distal ulnar implants using finite element analysis. J Orthop Res. 2011;29(9):1418–23.CrossRef Austman RL, King GJ, Dunning CE. Bone stresses before and after insertion of two commercially available distal ulnar implants using finite element analysis. J Orthop Res. 2011;29(9):1418–23.CrossRef
4.
go back to reference Darrach W. Partial Excision of Lower Shaft of Ulna for Deformity Following Colles’s Fracture. Clin Ortho Related Res (1976-2007). 1992;275:3–4. Darrach W. Partial Excision of Lower Shaft of Ulna for Deformity Following Colles’s Fracture. Clin Ortho Related Res (1976-2007). 1992;275:3–4.
5.
go back to reference Bieber EJ, Linscheid RL, Dobyns JH, Beckenbaugh RD. Failed distal ulna resections. J Hand Sur. 1988;13(2):193–200.CrossRef Bieber EJ, Linscheid RL, Dobyns JH, Beckenbaugh RD. Failed distal ulna resections. J Hand Sur. 1988;13(2):193–200.CrossRef
6.
go back to reference Field J, Majkowski R, Leslie I. Poor results of Darrach’s procedure after wrist injuries. Journal Bone Joint Surg Br. 1993;75(1):53–7.CrossRef Field J, Majkowski R, Leslie I. Poor results of Darrach’s procedure after wrist injuries. Journal Bone Joint Surg Br. 1993;75(1):53–7.CrossRef
7.
go back to reference Minami A, Iwasaki N, Ishikawa J-i, Suenaga N, Yasuda K, Kato H. Treatments of osteoarthritis of the distal radioulnar joint: long-term results of three procedures. Hand Surgery. 2005;10(02n03):243–8.CrossRef Minami A, Iwasaki N, Ishikawa J-i, Suenaga N, Yasuda K, Kato H. Treatments of osteoarthritis of the distal radioulnar joint: long-term results of three procedures. Hand Surgery. 2005;10(02n03):243–8.CrossRef
8.
go back to reference Bowers WH. Distal radioulnar joint arthroplasty: the hemiresection-interposition technique. J Hand Surg. 1985;10(2):169–78.CrossRef Bowers WH. Distal radioulnar joint arthroplasty: the hemiresection-interposition technique. J Hand Surg. 1985;10(2):169–78.CrossRef
9.
go back to reference Kapandji I. The Kapandji-Sauvé operation. Its techniques and indications in non rheumatoid diseases. Ann Chir Main. 1986;5(3):181–93.CrossRef Kapandji I. The Kapandji-Sauvé operation. Its techniques and indications in non rheumatoid diseases. Ann Chir Main. 1986;5(3):181–93.CrossRef
10.
go back to reference Lees V, Scheker L. The radiological demonstration of dynamic ulnar impingement. J Hand Surg. 1997;22(4):448–50.CrossRef Lees V, Scheker L. The radiological demonstration of dynamic ulnar impingement. J Hand Surg. 1997;22(4):448–50.CrossRef
11.
go back to reference Hagert C-G. The distal radioulnar joint in relation to the whole forearm. Clin Orthop Relat Res. 1992;275:56–64.CrossRef Hagert C-G. The distal radioulnar joint in relation to the whole forearm. Clin Orthop Relat Res. 1992;275:56–64.CrossRef
12.
go back to reference Laurentin-Pérez L, Goodwin A, Babb B, Scheker L. A study of functional outcomes following implantation of a total distal radioulnar joint prosthesis. J Hand Surg (Eur Volume). 2008;33(1):18–28.CrossRef Laurentin-Pérez L, Goodwin A, Babb B, Scheker L. A study of functional outcomes following implantation of a total distal radioulnar joint prosthesis. J Hand Surg (Eur Volume). 2008;33(1):18–28.CrossRef
13.
go back to reference Moradi A, Binava R, Vahedi E, Ebrahimzadeh MH, Jesse BJ. Distal Radioulnar Joint Prosthesis. Arch Bone Joint Surg. 2021;9(1):22–32.PubMedPubMedCentral Moradi A, Binava R, Vahedi E, Ebrahimzadeh MH, Jesse BJ. Distal Radioulnar Joint Prosthesis. Arch Bone Joint Surg. 2021;9(1):22–32.PubMedPubMedCentral
14.
go back to reference van Schoonhoven J, Fernandez DL, Bowers WH, Herbert TJ. Salvage of failed resection arthroplasties of the distal radioulnar joint using a new ulnar head prosthesis. Journal Hand Surg. 2000;25(3):438–46.CrossRef van Schoonhoven J, Fernandez DL, Bowers WH, Herbert TJ. Salvage of failed resection arthroplasties of the distal radioulnar joint using a new ulnar head prosthesis. Journal Hand Surg. 2000;25(3):438–46.CrossRef
15.
go back to reference Moradi A, Binava R, Hasanabadi SE, Vahedi E, Ebrahimzadeh MH. Introduction and Early Outcomes of Intraosseous Distal Radioulnar Joint Prosthesis: A Pilot Study and a Technique on a New Design of the Sauvé-Kapandji Procedure. Arch Bone Joint Surg. 2020;8(6):703.PubMedPubMedCentral Moradi A, Binava R, Hasanabadi SE, Vahedi E, Ebrahimzadeh MH. Introduction and Early Outcomes of Intraosseous Distal Radioulnar Joint Prosthesis: A Pilot Study and a Technique on a New Design of the Sauvé-Kapandji Procedure. Arch Bone Joint Surg. 2020;8(6):703.PubMedPubMedCentral
16.
go back to reference Moradi A, Binava R, Hedjazi A, Hasanabadi SE, Chaharjouy NT, Ebrahimzadeh MH. Biomechanical Evaluation of Intraosseous Distal Radioulnar Joint Prosthesis: A Prosthesis Designed Based on Sauvé-Kapandji Procedure. Orthop Traumatol Surg Res. 2021;107(5):102975.CrossRef Moradi A, Binava R, Hedjazi A, Hasanabadi SE, Chaharjouy NT, Ebrahimzadeh MH. Biomechanical Evaluation of Intraosseous Distal Radioulnar Joint Prosthesis: A Prosthesis Designed Based on Sauvé-Kapandji Procedure. Orthop Traumatol Surg Res. 2021;107(5):102975.CrossRef
17.
go back to reference Miguel-Andres I, Alonso-Rasgado T, Walmsley A, Watts AC. Effect of anconeus muscle blocking on elbow kinematics: electromyographic, inertial sensors and finite element study. Ann Biomed Eng. 2017;45(3):775–88.CrossRef Miguel-Andres I, Alonso-Rasgado T, Walmsley A, Watts AC. Effect of anconeus muscle blocking on elbow kinematics: electromyographic, inertial sensors and finite element study. Ann Biomed Eng. 2017;45(3):775–88.CrossRef
18.
go back to reference Rezende CEE, Chase-Diaz M, Costa MD, Albarracin ML, Paschoeto G, Sousa EAC, Rubo JH, Borges AFS. Stress distribution in single dental implant system: three-dimensional finite element analysis based on an in vitro experimental model. J Craniofacial Surg. 2015;26(7):2196–200.CrossRef Rezende CEE, Chase-Diaz M, Costa MD, Albarracin ML, Paschoeto G, Sousa EAC, Rubo JH, Borges AFS. Stress distribution in single dental implant system: three-dimensional finite element analysis based on an in vitro experimental model. J Craniofacial Surg. 2015;26(7):2196–200.CrossRef
19.
go back to reference Zhang Y, Shao Q, Yang C, Ai C, Zhou D, Yu Y, Sun G. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture. J Orthop Surg Res. 2021;16(1):1–13.CrossRef Zhang Y, Shao Q, Yang C, Ai C, Zhou D, Yu Y, Sun G. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture. J Orthop Surg Res. 2021;16(1):1–13.CrossRef
20.
go back to reference Khuyagbaatar B, Lee S-J, Cheon M, Batbayar T, Ganbat D, Kim YH. Effect of wrist-wearing distal radioulnar joint stabilizer on distal radioulnar joint instability using a forearm finite element model. J Mechanical Sci Technol. 2019;33(5):2503–8. Khuyagbaatar B, Lee S-J, Cheon M, Batbayar T, Ganbat D, Kim YH. Effect of wrist-wearing distal radioulnar joint stabilizer on distal radioulnar joint instability using a forearm finite element model. J Mechanical Sci Technol. 2019;33(5):2503–8.
21.
go back to reference Dhason R, Roy S, Datta S. A biomechanical study on the laminate stacking sequence in composite bone plates for vancouver femur B1 fracture fixation. Comput Methods Programs Biomed. 2020;196:105680.CrossRef Dhason R, Roy S, Datta S. A biomechanical study on the laminate stacking sequence in composite bone plates for vancouver femur B1 fracture fixation. Comput Methods Programs Biomed. 2020;196:105680.CrossRef
22.
go back to reference Bajuri M, Kadir MRA, Murali MR, Kamarul T. Biomechanical analysis of the wrist arthroplasty in rheumatoid arthritis: a finite element analysis. Med Biol Eng Compu. 2013;51(1):175–86.CrossRef Bajuri M, Kadir MRA, Murali MR, Kamarul T. Biomechanical analysis of the wrist arthroplasty in rheumatoid arthritis: a finite element analysis. Med Biol Eng Compu. 2013;51(1):175–86.CrossRef
23.
go back to reference Tan J, Mu M, Liao G, Zhao Y, Li J. Biomechanical analysis of the annular ligament in Monteggia fractures using finite element models. J Orthop Surg Res. 2015;10(1):1–6.CrossRef Tan J, Mu M, Liao G, Zhao Y, Li J. Biomechanical analysis of the annular ligament in Monteggia fractures using finite element models. J Orthop Surg Res. 2015;10(1):1–6.CrossRef
24.
go back to reference Ashrafi M, Ghalichi F, Mirzakouchaki B, Doblare M. On the effect of antiresorptive drugs on the bone remodeling of the mandible after dental implantation: a mathematical model. Sci Rep. 2021;11(1):1–20.CrossRef Ashrafi M, Ghalichi F, Mirzakouchaki B, Doblare M. On the effect of antiresorptive drugs on the bone remodeling of the mandible after dental implantation: a mathematical model. Sci Rep. 2021;11(1):1–20.CrossRef
25.
go back to reference Ashrafi M, Ghalichi F, Mirzakouchaki B, ZoljanahiOskui I. Numerical simulation of hydro-mechanical coupling of periodontal ligament. Proc Inst Mech Eng [H]. 2020;234(2):171–8.CrossRef Ashrafi M, Ghalichi F, Mirzakouchaki B, ZoljanahiOskui I. Numerical simulation of hydro-mechanical coupling of periodontal ligament. Proc Inst Mech Eng [H]. 2020;234(2):171–8.CrossRef
26.
go back to reference Ashrafi M, Gubaua JE, Pereira JT, Gahlichi F, Doblaré M. A mechano-chemo-biological model for bone remodeling with a new mechano-chemo-transduction approach. Biomech Model Mechanobiol. 2020;19(6):2499–523.CrossRef Ashrafi M, Gubaua JE, Pereira JT, Gahlichi F, Doblaré M. A mechano-chemo-biological model for bone remodeling with a new mechano-chemo-transduction approach. Biomech Model Mechanobiol. 2020;19(6):2499–523.CrossRef
27.
go back to reference Ashrafi M, Ghalichi F, Mirzakouchaki B, Arruga A, Doblare M. Finite element comparison of the effect of absorbers’ design in the surrounding bone of dental implants. Int J Numer Methods Biomed Eng. 2020;36(1):e3270.CrossRef Ashrafi M, Ghalichi F, Mirzakouchaki B, Arruga A, Doblare M. Finite element comparison of the effect of absorbers’ design in the surrounding bone of dental implants. Int J Numer Methods Biomed Eng. 2020;36(1):e3270.CrossRef
Metadata
Title
Finite element analysis of intraosseous distal radioulnar joint prosthesis
Authors
Farzaneh Gholamian
Mehran Ashrafi
Ali Moradi
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2022
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-022-05746-3

Other articles of this Issue 1/2022

BMC Musculoskeletal Disorders 1/2022 Go to the issue