Skip to main content
Top
Published in: Journal of Robotic Surgery 4/2019

01-08-2019 | Fertility | Brief Communication

Wearable haptic interfaces for applications in gynecologic robotic surgery: a proof of concept in robotic myomectomy

Authors: Andrea Giannini, Matteo Bianchi, Davide Doria, Simone Fani, Marta Caretto, Antonio Bicchi, Tommaso Simoncini

Published in: Journal of Robotic Surgery | Issue 4/2019

Login to get access

Abstract

Uterine fibromatosis is common in women, with an estimated prevalence of up to 15–50% after 35 years. About 80% of women affected by fibromatosis have symptoms and require medical or surgical treatment. Nowadays, the gold standard for the surgical treatment of uterine fibromatosis is the use of minimally invasive surgery. The surgical skills and improvements offered by robotic approach can be relevant in reproductive surgery, in particular in minimally invasive myomectomy. However, the lack of tactile feedback of robotic platform is an important technical drawback that can reduce the accuracy of surgical procedures. Here, we present the design and the preliminary test of the wearable fabric, yielding display wearable haptic interfaces able to generate a real-time tactile feedback in terms of stiffness for applications in gynecologic robotic surgery. We preliminarily tested the device in the simulation of a real scenario of conservative myomectomy with the final purpose of increasing the accuracy and precision during surgery. The future goal is the integration of a haptic device with the commercially available robotic surgical systems with the purpose of improving the precision and accuracy of the surgical operation, thus allowing a better understanding concerning the anatomical relationship of the target structures. This in turn could determine a change in the surgical strategy in some cases, letting some patients selected for a demolitive approach retaining their uterus. This could improve surgical outcomes in fertile women enrolled for minimally invasive surgery for uterine fibroids and may be a facilitation for young gynecological surgeons or during residency teaching plans and learning programs.
Literature
1.
2.
go back to reference Falcone T, Parker WH (2013) Surgical management of leiomyomas for fertility or uterine preservation. Obstet Gynecol 121(4):856–868CrossRefPubMed Falcone T, Parker WH (2013) Surgical management of leiomyomas for fertility or uterine preservation. Obstet Gynecol 121(4):856–868CrossRefPubMed
3.
go back to reference Nieboer TE, Johnson N, Lethaby A, Tavender E, Curr E, Garry R et al (2009) Surgical approach to hysterectomy for benign gynaecological disease. Cochrane Database Syst Rev 3:CD003677 Nieboer TE, Johnson N, Lethaby A, Tavender E, Curr E, Garry R et al (2009) Surgical approach to hysterectomy for benign gynaecological disease. Cochrane Database Syst Rev 3:CD003677
4.
go back to reference Gynecologists, A. C. o. O. a. (2009) ACOG Committee Opinion No. 444. Choosing the route of hysterectomy for benign disease. Obstet Gynecol 114:1156–1158CrossRef Gynecologists, A. C. o. O. a. (2009) ACOG Committee Opinion No. 444. Choosing the route of hysterectomy for benign disease. Obstet Gynecol 114:1156–1158CrossRef
5.
go back to reference Bhave Chittawar P, Franik S, Pouwer AW, Farquhar C (2014) Minimally invasive surgical techniques versus open myomectomy for uterine fibroids. Cochrane Database Syst Rev 10:CD004638 Bhave Chittawar P, Franik S, Pouwer AW, Farquhar C (2014) Minimally invasive surgical techniques versus open myomectomy for uterine fibroids. Cochrane Database Syst Rev 10:CD004638
6.
go back to reference Sizzi O, Rossetti A, Malzoni M et al (2007) Italian multicenter study on complications of laparoscopic myomectomy. J Minim Invasive Gynecol 14(4):453–462CrossRefPubMed Sizzi O, Rossetti A, Malzoni M et al (2007) Italian multicenter study on complications of laparoscopic myomectomy. J Minim Invasive Gynecol 14(4):453–462CrossRefPubMed
8.
go back to reference Levine DJ, Berman JM, Harris M, Chudnoff SG, Whaley FS, Palmer SL (2013) Sensitivity of myoma imaging using laparoscopic ultrasound compared with magnetic resonance imaging and transvaginal ultrasound. J Minim Invasive Gynecol 20(6):770–774CrossRefPubMed Levine DJ, Berman JM, Harris M, Chudnoff SG, Whaley FS, Palmer SL (2013) Sensitivity of myoma imaging using laparoscopic ultrasound compared with magnetic resonance imaging and transvaginal ultrasound. J Minim Invasive Gynecol 20(6):770–774CrossRefPubMed
9.
go back to reference Condino S, Viglialoro RM, Fani S, Bianchi M, Morelli L, Ferrari M, Bicchi A, Ferrari V (2016) Tactile augmented reality for arteries palpation in open surgery training. In: International conference on medical imaging and virtual reality, pp 186–197 Condino S, Viglialoro RM, Fani S, Bianchi M, Morelli L, Ferrari M, Bicchi A, Ferrari V (2016) Tactile augmented reality for arteries palpation in open surgery training. In: International conference on medical imaging and virtual reality, pp 186–197
10.
go back to reference Fani S, Ciotti S, Battaglia E, Moscatelli A, Bianchi M (2017) W-FYD: a wearable fabric-based display for haptic multi-cue delivery and tactile augmented reality. In: IEEE transactions on haptics, p 1 Fani S, Ciotti S, Battaglia E, Moscatelli A, Bianchi M (2017) W-FYD: a wearable fabric-based display for haptic multi-cue delivery and tactile augmented reality. In: IEEE transactions on haptics, p 1
11.
go back to reference Bianchi M, Battaglia E, Poggiani S, Ciotti S, Bicchi A (2016) A wearable fabric-based display for haptic multi-cue delivery. In: 2016 IEEE haptics symposium (HAPTICS), pp 277–283 Bianchi M, Battaglia E, Poggiani S, Ciotti S, Bicchi A (2016) A wearable fabric-based display for haptic multi-cue delivery. In: 2016 IEEE haptics symposium (HAPTICS), pp 277–283
Metadata
Title
Wearable haptic interfaces for applications in gynecologic robotic surgery: a proof of concept in robotic myomectomy
Authors
Andrea Giannini
Matteo Bianchi
Davide Doria
Simone Fani
Marta Caretto
Antonio Bicchi
Tommaso Simoncini
Publication date
01-08-2019
Publisher
Springer London
Published in
Journal of Robotic Surgery / Issue 4/2019
Print ISSN: 1863-2483
Electronic ISSN: 1863-2491
DOI
https://doi.org/10.1007/s11701-019-00971-w

Other articles of this Issue 4/2019

Journal of Robotic Surgery 4/2019 Go to the issue