Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool

Authors: M. Fawad Khan, Stefan Wesarg, Jessen Gurung, Selami Dogan, Adel Maataoui, Boris Brehmer, Christopher Herzog, Hanns Ackermann, Birgit Aßmus, Thomas J. Vogl

Published in: European Radiology | Issue 8/2006

Login to get access

Abstract

The purpose of this study was to investigate a 3D coronary artery segmentation algorithm using 16-row MDCT data sets. Fifty patients underwent cardiac CT (Sensation 16, Siemens) and coronary angiography. Automatic and manual detection of coronary artery stenosis was performed. A 3D coronary artery segmentation algorithm (Fraunhofer Institute for Computer Graphics, Darmstadt) was used for automatic evaluation. All significant stenoses (>50%) in vessels >1.5 mm in diameter were protocoled. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of coronary angiography. Sensitivity and specificity were determined for automatic and manual detection as well as was the time for both CT-based evaluation methods. The overall sensitivity and specificity of the automatic and manual approach were 93.1 vs. 95.83% and 86.1 vs. 81.9%. The time required for automatic evaluation was significantly shorter than with the manual approach, i.e., 246.04±43.17 s for the automatic approach and 526.88±45.71 s for the manual approach (P<0.0001). In 94% of the coronary artery branches, automatic detection required less time than the manual approach. Automatic coronary vessel evaluation is feasible. It reduces the time required for cardiac CT evaluation with similar sensitivity and specificity as well as facilitates the evaluation of MDCT coronary angiography in a standardized fashion.
Literature
1.
go back to reference Milan E (2005) Coronary artery disease. The other half of the heaven. Q J Nucl Med Mol Imaging 49:72–80PubMed Milan E (2005) Coronary artery disease. The other half of the heaven. Q J Nucl Med Mol Imaging 49:72–80PubMed
2.
go back to reference Raggi P (2001) The use of electron-beam computed tomography as a tool for primary prevention. Am J Cardiol 88:28J–32JPubMedCrossRef Raggi P (2001) The use of electron-beam computed tomography as a tool for primary prevention. Am J Cardiol 88:28J–32JPubMedCrossRef
3.
go back to reference Saxon LA (2005) Sudden cardiac death: epidemiology and temporal trends. Rev Cardiovasc Med 6 (Suppl 2):S12–S20PubMed Saxon LA (2005) Sudden cardiac death: epidemiology and temporal trends. Rev Cardiovasc Med 6 (Suppl 2):S12–S20PubMed
4.
go back to reference Zheng ZJ, Croft JB, Giles WH, Mensah GA (2001) Sudden cardiac death in the United States, 1989 to 1998. Circulation 104:2158–2163PubMedCrossRef Zheng ZJ, Croft JB, Giles WH, Mensah GA (2001) Sudden cardiac death in the United States, 1989 to 1998. Circulation 104:2158–2163PubMedCrossRef
5.
go back to reference Ropers D, Baum U, Pohle K et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed Ropers D, Baum U, Pohle K et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed
6.
go back to reference Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054CrossRefPubMed Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054CrossRefPubMed
7.
go back to reference Cademartiri F, Malagutti P, Belgrano M et al (2005) Non-invasive coronary angiography with 64-slice computed tomography. Minerva Cardioangiol 53:465–472PubMed Cademartiri F, Malagutti P, Belgrano M et al (2005) Non-invasive coronary angiography with 64-slice computed tomography. Minerva Cardioangiol 53:465–472PubMed
8.
go back to reference Lenzen MJ, Boersma E, Bertrand ME et al (2005) Management and outcome of patients with established coronary artery disease: the Euro Heart Survey on coronary revascularization. Eur Heart J 26:1169–1179PubMedCrossRef Lenzen MJ, Boersma E, Bertrand ME et al (2005) Management and outcome of patients with established coronary artery disease: the Euro Heart Survey on coronary revascularization. Eur Heart J 26:1169–1179PubMedCrossRef
9.
go back to reference Dewey M, Schnapauff D, Laule M et al (2004) Multislice CT coronary angiography: evaluation of an automatic vessel detection tool. Rofo 176:478–483PubMed Dewey M, Schnapauff D, Laule M et al (2004) Multislice CT coronary angiography: evaluation of an automatic vessel detection tool. Rofo 176:478–483PubMed
10.
go back to reference Wesarg S (2005) Supporting the TECAB grafting through CT based analysis of coronary arteries. In: Frangi, AF (ed) u.a.: Functional imaging and modeling of the heart. Proceedings Berlin, Heidelberg, New York: Springer Verlag, pp. 133–142 (Lecture Notes in Computer Science 3504) Wesarg S (2005) Supporting the TECAB grafting through CT based analysis of coronary arteries. In: Frangi, AF (ed) u.a.: Functional imaging and modeling of the heart. Proceedings Berlin, Heidelberg, New York: Springer Verlag, pp. 133–142 (Lecture Notes in Computer Science 3504)
11.
go back to reference Herzog C, Dogan S, Diebold T et al (2003) Multi-detector row CT versus coronary angiography: preoperative evaluation before totally endoscopic coronary artery bypass grafting. Radiology 229:200–208PubMedCrossRef Herzog C, Dogan S, Diebold T et al (2003) Multi-detector row CT versus coronary angiography: preoperative evaluation before totally endoscopic coronary artery bypass grafting. Radiology 229:200–208PubMedCrossRef
12.
go back to reference Fleischmann D (2003) High-concentration contrast media in MDCT angiography:principles and rationale. Eur Radiol 13 (Suppl. 3):39–43CrossRef Fleischmann D (2003) High-concentration contrast media in MDCT angiography:principles and rationale. Eur Radiol 13 (Suppl. 3):39–43CrossRef
13.
go back to reference Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed
14.
15.
go back to reference Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed
16.
go back to reference Hamoir XL, Flohr T, Hamoir V et al (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time. Eur Radiol 15:296–304CrossRefPubMed Hamoir XL, Flohr T, Hamoir V et al (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time. Eur Radiol 15:296–304CrossRefPubMed
17.
go back to reference Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463PubMed Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463PubMed
18.
go back to reference Hong C, Becker CR, Huber A, et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717PubMedCrossRef Hong C, Becker CR, Huber A, et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717PubMedCrossRef
19.
go back to reference Kopp AF, Ohnesorge B, Flohr T et al (2000) [Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 172:429–435PubMedCrossRef Kopp AF, Ohnesorge B, Flohr T et al (2000) [Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 172:429–435PubMedCrossRef
20.
go back to reference Georg C, Kopp A, Schroder S et al (2001) [Optimizing image reconstruction timing for the RR interval in imaging coronary arteries with multi-slice computerized tomography]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:536–541PubMedCrossRef Georg C, Kopp A, Schroder S et al (2001) [Optimizing image reconstruction timing for the RR interval in imaging coronary arteries with multi-slice computerized tomography]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:536–541PubMedCrossRef
21.
go back to reference Heuschmid M, Kuettner A, Schroeder S et al (2005) ECG-gated 16-MDCT of the coronary arteries: Assessment of image quality and accuracy in detecting stenoses. AJR Am J Roentgenol 184:1413–1419PubMed Heuschmid M, Kuettner A, Schroeder S et al (2005) ECG-gated 16-MDCT of the coronary arteries: Assessment of image quality and accuracy in detecting stenoses. AJR Am J Roentgenol 184:1413–1419PubMed
22.
go back to reference Leschka S, Alkadhi H, Plass A et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J Leschka S, Alkadhi H, Plass A et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J
23.
go back to reference Morgan-Hughes GJ, Roobottom CA, Owens PE, Marshall AJ (2005) Highly accurate coronary angiography with submillimetre, 16 slice computed tomography. Heart 91:308–313PubMedCrossRef Morgan-Hughes GJ, Roobottom CA, Owens PE, Marshall AJ (2005) Highly accurate coronary angiography with submillimetre, 16 slice computed tomography. Heart 91:308–313PubMedCrossRef
24.
go back to reference Zhang SZ, Hu XH, Zhang QW, Huang WX (2005) Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time. Eur Radiol 15:1105–1109CrossRefPubMed Zhang SZ, Hu XH, Zhang QW, Huang WX (2005) Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time. Eur Radiol 15:1105–1109CrossRefPubMed
25.
go back to reference Herzog C, Dogan S, Wimmer-Greinecker G, Balzer JO, Mack MG, Vogl TJ (2003) Multidetector-row CT: cardiosurgery indications. Eur Radiol 13 (Suppl 5):M82–M87PubMed Herzog C, Dogan S, Wimmer-Greinecker G, Balzer JO, Mack MG, Vogl TJ (2003) Multidetector-row CT: cardiosurgery indications. Eur Radiol 13 (Suppl 5):M82–M87PubMed
26.
go back to reference Bley TA, Ghanem NA, Foell D et al (2005) Computed tomography coronary angiography with 370-millisecond gantry rotation time: evaluation of the best image reconstruction interval. J Comput Assist Tomogr 29:1–5CrossRefPubMed Bley TA, Ghanem NA, Foell D et al (2005) Computed tomography coronary angiography with 370-millisecond gantry rotation time: evaluation of the best image reconstruction interval. J Comput Assist Tomogr 29:1–5CrossRefPubMed
27.
go back to reference Cademartiri F, Luccichenti G, Marano R, Runza G, Midiri M (2004) Use of saline chaser in the intravenous administration of contrast material in non-invasive coronary angiography with 16-row multislice computed tomography. Radiol Med (Torino) 107:497–505 Cademartiri F, Luccichenti G, Marano R, Runza G, Midiri M (2004) Use of saline chaser in the intravenous administration of contrast material in non-invasive coronary angiography with 16-row multislice computed tomography. Radiol Med (Torino) 107:497–505
28.
go back to reference Cademartiri F, Luccichenti G, Marano R, Gualerzi M, Brambilla L, Coruzzi P (2004) Comparison of monophasic vs biphasic administration of contrast material in non-invasive coronary angiography using a 16-row multislice computed tomography. Radiol Med (Torino) 107:489–496 Cademartiri F, Luccichenti G, Marano R, Gualerzi M, Brambilla L, Coruzzi P (2004) Comparison of monophasic vs biphasic administration of contrast material in non-invasive coronary angiography using a 16-row multislice computed tomography. Radiol Med (Torino) 107:489–496
29.
go back to reference Cademartiri F, Luccichenti G, van Der Lugt A et al (2004) Sixteen-row multislice computed tomography: basic concepts, protocols, and enhanced clinical applications. Semin Ultrasound CT MR 25:2–16CrossRefPubMed Cademartiri F, Luccichenti G, van Der Lugt A et al (2004) Sixteen-row multislice computed tomography: basic concepts, protocols, and enhanced clinical applications. Semin Ultrasound CT MR 25:2–16CrossRefPubMed
30.
go back to reference Hoffmann MH, Shi H, Manzke R et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97PubMedCrossRef Hoffmann MH, Shi H, Manzke R et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97PubMedCrossRef
31.
go back to reference Kopp AF, Kuttner A, Trabold T, Heuschmid M, Schroder S, Claussen CD (2003) MDCT: cardiology indications. Eur Radiol 13 (Suppl 5):M102–M115PubMed Kopp AF, Kuttner A, Trabold T, Heuschmid M, Schroder S, Claussen CD (2003) MDCT: cardiology indications. Eur Radiol 13 (Suppl 5):M102–M115PubMed
32.
go back to reference Francone M, Carbone I, Danti M et al (2005) ECG-gated multi-detector row spiral CT in the assessment of myocardial infarction: correlation with non-invasive angiographic findings. Eur Radiol. DOI 10.1007/s00330-005-2800-3 Francone M, Carbone I, Danti M et al (2005) ECG-gated multi-detector row spiral CT in the assessment of myocardial infarction: correlation with non-invasive angiographic findings. Eur Radiol. DOI 10.1007/s00330-005-2800-3
33.
go back to reference Marano R, Storto ML, Maddestra N, Bonomo L (2004) Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography. Eur Radiol 14:1353–1362CrossRefPubMed Marano R, Storto ML, Maddestra N, Bonomo L (2004) Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography. Eur Radiol 14:1353–1362CrossRefPubMed
34.
go back to reference Vogl TJ, Abolmaali ND, Diebold T et al (2002) Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 223:212–220PubMedCrossRef Vogl TJ, Abolmaali ND, Diebold T et al (2002) Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 223:212–220PubMedCrossRef
35.
go back to reference Khan MF, Herzog C, Landenberger K et al (2005) Visualisation of non-invasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography. Eur Radiol 15:118–126CrossRefPubMed Khan MF, Herzog C, Landenberger K et al (2005) Visualisation of non-invasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography. Eur Radiol 15:118–126CrossRefPubMed
36.
go back to reference Khan MF, Herzog C, Landenberger K et al (2005) MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation. Eur Radiol 15:305–311CrossRefPubMed Khan MF, Herzog C, Landenberger K et al (2005) MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation. Eur Radiol 15:305–311CrossRefPubMed
37.
go back to reference van Ooijen PM, Ho KY, Dorgelo J, Oudkerk M (2003) Coronary artery imaging with multidetector CT: visualization issues. Radiographics 23:e16PubMedCrossRef van Ooijen PM, Ho KY, Dorgelo J, Oudkerk M (2003) Coronary artery imaging with multidetector CT: visualization issues. Radiographics 23:e16PubMedCrossRef
38.
go back to reference Nakanishi T, Kayashima Y, Inoue R, Sumii K, Gomyo Y (2005) Pitfalls in 16-detector row CT of the coronary arteries. Radiographics 25:425–438; discussion 438–440PubMedCrossRef Nakanishi T, Kayashima Y, Inoue R, Sumii K, Gomyo Y (2005) Pitfalls in 16-detector row CT of the coronary arteries. Radiographics 25:425–438; discussion 438–440PubMedCrossRef
39.
go back to reference Choi HS, Choi BW, Choe KO et al (2004) Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography. Radiographics 24:787–800PubMedCrossRef Choi HS, Choi BW, Choe KO et al (2004) Pitfalls, artifacts, and remedies in multi- detector row CT coronary angiography. Radiographics 24:787–800PubMedCrossRef
40.
go back to reference Kirbas C, Quek K (2003) Vessel extraction techniques and algorithms: A survey. In: Proc of the 3rd IEEE Symposium on Bioinformatics and Bioengineering 238–245 Kirbas C, Quek K (2003) Vessel extraction techniques and algorithms: A survey. In: Proc of the 3rd IEEE Symposium on Bioinformatics and Bioengineering 238–245
41.
go back to reference Yoo TSe (2004) Insight into images. A K Peters, Ltd Yoo TSe (2004) Insight into images. A K Peters, Ltd
42.
go back to reference Sorantin E, Halmai C, Erdohely B et al (2002) Spiral-CT-based assessment of tracheal stenoses using 3-D-skeletonization. IEEE Trans Med Imag 21:263–273CrossRef Sorantin E, Halmai C, Erdohely B et al (2002) Spiral-CT-based assessment of tracheal stenoses using 3-D-skeletonization. IEEE Trans Med Imag 21:263–273CrossRef
43.
go back to reference Verdonck B, Bloch I, Maître H, Vandermeulen D, Suetens P, Marchal G (1995) Blood vessel segmentation and visualization in 3D MR and spiral CT angiography. In: Lemke, H.U. (ed): Computer assisted radiology. Proc of the CAR, Springer 177–182 Verdonck B, Bloch I, Maître H, Vandermeulen D, Suetens P, Marchal G (1995) Blood vessel segmentation and visualization in 3D MR and spiral CT angiography. In: Lemke, H.U. (ed): Computer assisted radiology. Proc of the CAR, Springer 177–182
Metadata
Title
Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool
Authors
M. Fawad Khan
Stefan Wesarg
Jessen Gurung
Selami Dogan
Adel Maataoui
Boris Brehmer
Christopher Herzog
Hanns Ackermann
Birgit Aßmus
Thomas J. Vogl
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0159-8

Other articles of this Issue 8/2006

European Radiology 8/2006 Go to the issue