Skip to main content
Top
Published in: European Journal of Trauma and Emergency Surgery 3/2014

01-06-2014 | Review Article

Extramedullary fixation of trochanteric hip fracture

Author: M. J. Parker

Published in: European Journal of Trauma and Emergency Surgery | Issue 3/2014

Login to get access

Abstract

Extramedullary fixation with a sliding hip screw remains the treatment of choice for the majority of trochanteric hip fractures. Attention to surgical detail is far more important that the actual choice of implant. The fracture must be reduced to an anatomical or slight valgus position using the fracture table. Surgical exposure need not be excessive as most fractures can be reduced by closed means. The position of the lag screw is critical to achieve a central to inferior position on the anterior–posterior radiograph and a central position on the lateral view. A four-hole plate should suffice for most fractures. After surgery, weight bearing as able should be allowed. For fractures fixed correctly, wound or fracture healing complication should be rare, occurring in <5 % of cases.
Literature
1.
go back to reference National Clinical Guideline Centre (NICE), The Management of Hip Fracture in Adults]. London: National Clinical Guideline Centre. Available from 2011. www.ncgc.ac.uk. National Clinical Guideline Centre (NICE), The Management of Hip Fracture in Adults]. London: National Clinical Guideline Centre. Available from 2011. www.​ncgc.​ac.​uk.
2.
go back to reference Parker MJ, Handoll HHG. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database of Systematic Reviews 2010, Issue 9. Art. No.: CD000093. doi:10.1002/14651858.CD000093.pub5. Parker MJ, Handoll HHG. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database of Systematic Reviews 2010, Issue 9. Art. No.: CD000093. doi:10.​1002/​14651858.​CD000093.​pub5.
3.
go back to reference Parker MJ, Bowers TR, Pryor GA. Sliding hip screw versus the Targon PF nail in the treatment of trochanteric fractures of the hip: a randomised trial of 600 fractures. J Bone Jt Surg Br. 2012;94(B):391–7.CrossRef Parker MJ, Bowers TR, Pryor GA. Sliding hip screw versus the Targon PF nail in the treatment of trochanteric fractures of the hip: a randomised trial of 600 fractures. J Bone Jt Surg Br. 2012;94(B):391–7.CrossRef
4.
go back to reference Parker MJ, Handoll HHG. Pre-operative traction for fractures of the proximal femur in adults. (Cochrane Review). In: The Cochrane Library, Issue 3,2006. Chichester: Wiley. Art. No.: CD000168. doi:10.1002/14651858.CD000168.pub2. Parker MJ, Handoll HHG. Pre-operative traction for fractures of the proximal femur in adults. (Cochrane Review). In: The Cochrane Library, Issue 3,2006. Chichester: Wiley. Art. No.: CD000168. doi:10.​1002/​14651858.​CD000168.​pub2.
6.
go back to reference Garden RS. Low-angle fixation in fractures of the femoral neck. J Bone Jt Surg. 1961;43-B:647–63. Garden RS. Low-angle fixation in fractures of the femoral neck. J Bone Jt Surg. 1961;43-B:647–63.
7.
go back to reference Baumgaertner MR, Solberg BD. Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Jt Surg. 1997;79-B:969–71.CrossRef Baumgaertner MR, Solberg BD. Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Jt Surg. 1997;79-B:969–71.CrossRef
8.
go back to reference Parker MJ. Trochanteric hip fractures; fixation failure commoner with femoral medialisation, a comparison of 101 cases. Acta Orthop Scand. 1996;67:329–32.PubMedCrossRef Parker MJ. Trochanteric hip fractures; fixation failure commoner with femoral medialisation, a comparison of 101 cases. Acta Orthop Scand. 1996;67:329–32.PubMedCrossRef
9.
go back to reference Medoff RJ, Maes K. A new device for the fixation of unstable pertrochanteric fractures of the hip. J Bone Jt Surg. 1991;73-A:1192–9. Medoff RJ, Maes K. A new device for the fixation of unstable pertrochanteric fractures of the hip. J Bone Jt Surg. 1991;73-A:1192–9.
10.
go back to reference Lunsjo K, Ceder L, Stigsson L, Hauggaard A. Two-way compression along the shaft and the neck of the femur with the Medoff sliding plate: one-year follow-up of 108 intertrochanteric fractures. J Bone Jt Surg Br. 1996;78(B):387–90. Lunsjo K, Ceder L, Stigsson L, Hauggaard A. Two-way compression along the shaft and the neck of the femur with the Medoff sliding plate: one-year follow-up of 108 intertrochanteric fractures. J Bone Jt Surg Br. 1996;78(B):387–90.
11.
go back to reference Gotfried Y. Percutaneous compression plating of intertrochanteric hip fractures. J Orthop Trauma. 2000;14:490–5.PubMedCrossRef Gotfried Y. Percutaneous compression plating of intertrochanteric hip fractures. J Orthop Trauma. 2000;14:490–5.PubMedCrossRef
12.
go back to reference Yang E, Qureshi S, Trokhan S, Joseph D. Gotfried percutaneous compression plating compared with sliding hip screw fixation of intertrochanteric hip fractures: a prospective randomized study. J Bone Jt Surg Am. 2011;93(10):942–7.CrossRef Yang E, Qureshi S, Trokhan S, Joseph D. Gotfried percutaneous compression plating compared with sliding hip screw fixation of intertrochanteric hip fractures: a prospective randomized study. J Bone Jt Surg Am. 2011;93(10):942–7.CrossRef
Metadata
Title
Extramedullary fixation of trochanteric hip fracture
Author
M. J. Parker
Publication date
01-06-2014
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Trauma and Emergency Surgery / Issue 3/2014
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-013-0365-4

Other articles of this Issue 3/2014

European Journal of Trauma and Emergency Surgery 3/2014 Go to the issue

ESTES News 3.2014

ESTES NEWS 3.2014