Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2022

Open Access 01-12-2022 | External Fixator | Research

Staged correction trajectory with hexapod external fixator for the satisfactory reduction of long bone shaft fracture

Authors: Yanshi Liu, Fei Wang, Kai Liu, Feiyu Cai, Xingpeng Zhang, Hong Li, Tao Zhang, Aihemaitijiang Yusufu

Published in: BMC Musculoskeletal Disorders | Issue 1/2022

Login to get access

Abstract

Backgroud

When the reduction of long bone shaft fracture fragments is performed by a hexapod external fixator, the collision and interference between bony ends often results in an incomplete reduction and a time-consuming procedure. The purpose of this study was to present and determine the clinical effectiveness of staged correction trajectory with hexapod external fixator in the reduction of a long bone shaft fracture.

Methods

A total of 57 patients with tibial shaft fractures treated by hexapod external fixator were retrospectively analyzed from June 2016 to February 2020. Thirty-one cases (Group I) underwent a conventional one-step reduction trajectory from June 2016 to July 2018. Starting in September 2018, the other twenty-six patients (Group II) underwent staged correction trajectory (three key points reduction trajectory of “distraction-derotation-reduction”). The demographic data, residual deformities before and after correction, number of repeated X-rays after the first postoperative X-ray, duration of deformity correction process, and external fixation time were analyzed. Johner-Wruhs criteria were used to evaluate the final clinical outcomes.

Results

All the 57 patients achieved satisfactory fracture reduction and bone union. There were no significant differences between the two groups in demographic data, residual deformities before and after correction, external fixation time, and final clinical outcomes (p > 0.05). The average number of repeated X-rays after the first postoperative X-ray and mean duration of deformity correction process in Group II (1.3 times, 2.9 days) were all less than those in Group I (2.3 times, 5.1 days) (p < 0.05).

Conclusion

Compared with the conventional one-step reduction trajectory, there is no differences in final clinical outcomes, but the staged correction trajectory provides less repeated X-rays and shorter reduction process duration.
Literature
1.
go back to reference Paley D, Fleming B, Catagni M, Kristiansen T, Pope M. Mechanical evaluation of external fixators used in limb lengthening. Clin Orthop Relat Res. 1990:50–7. Paley D, Fleming B, Catagni M, Kristiansen T, Pope M. Mechanical evaluation of external fixators used in limb lengthening. Clin Orthop Relat Res. 1990:50–7.
2.
go back to reference Hak DJ, Toker S, Yi C, Toreson J. The influence of fracture fixation biomechanics on fracture healing. Orthopedics. 2010;33:752–5.CrossRef Hak DJ, Toker S, Yi C, Toreson J. The influence of fracture fixation biomechanics on fracture healing. Orthopedics. 2010;33:752–5.CrossRef
3.
go back to reference Mullins MM, Davidson AW, Goodier D, Barry M. The biomechanics of wire fixation in the Ilizarov system. Injury. 2003;34:155–7.CrossRef Mullins MM, Davidson AW, Goodier D, Barry M. The biomechanics of wire fixation in the Ilizarov system. Injury. 2003;34:155–7.CrossRef
4.
go back to reference Liu Y, Liu J, Yushan M, Liu Z, Zhang T, Ma H, et al. Management of high-energy tibial shaft fractures using the hexapod circular external fixator. BMC Surg. 2021;21:95.CrossRef Liu Y, Liu J, Yushan M, Liu Z, Zhang T, Ma H, et al. Management of high-energy tibial shaft fractures using the hexapod circular external fixator. BMC Surg. 2021;21:95.CrossRef
5.
go back to reference Wani N, Baba A, Kangoo K, Mir M. Role of early Ilizarov ring fixator in the definitive management of type II, IIIA and IIIB open tibial shaft fractures. Int Orthop. 2011;35:915–23.CrossRef Wani N, Baba A, Kangoo K, Mir M. Role of early Ilizarov ring fixator in the definitive management of type II, IIIA and IIIB open tibial shaft fractures. Int Orthop. 2011;35:915–23.CrossRef
6.
go back to reference Rogers GP, Tan HB, Foster P, Harwood P. Complex Tibial shaft fractures in children involving the distal Physis managed with the Ilizarov method. Strategies Trauma Limb Reconstr. 2019;14:20–4.CrossRef Rogers GP, Tan HB, Foster P, Harwood P. Complex Tibial shaft fractures in children involving the distal Physis managed with the Ilizarov method. Strategies Trauma Limb Reconstr. 2019;14:20–4.CrossRef
7.
go back to reference Thabet AM, Gerzina C, Sala F, Jeon S, Lovisetti G, Abdelgawad A, et al. Outcomes and complications with treatment of open Tibial plafond fractures with circular external fixator. Foot Ankle Int. 2021;42:723–33.CrossRef Thabet AM, Gerzina C, Sala F, Jeon S, Lovisetti G, Abdelgawad A, et al. Outcomes and complications with treatment of open Tibial plafond fractures with circular external fixator. Foot Ankle Int. 2021;42:723–33.CrossRef
8.
go back to reference Keshet D, Eidelman M. Clinical utility of the Taylor spatial frame for limb deformities. Orthop Res Rev. 2017;9:51–61.PubMedPubMedCentral Keshet D, Eidelman M. Clinical utility of the Taylor spatial frame for limb deformities. Orthop Res Rev. 2017;9:51–61.PubMedPubMedCentral
9.
go back to reference Potgieter MS, Pretorius HS, Preez GD, Burger M, Ferreira N. Complications associated with hexapod circular fixation for acute fractures of the tibia diaphysis: a retrospective descriptive study at a high volume trauma Centre. Injury. 2020;51:516–21.CrossRef Potgieter MS, Pretorius HS, Preez GD, Burger M, Ferreira N. Complications associated with hexapod circular fixation for acute fractures of the tibia diaphysis: a retrospective descriptive study at a high volume trauma Centre. Injury. 2020;51:516–21.CrossRef
10.
go back to reference Sala F, Thabet AM, Capitani P, Bove F, Abdelgawad AA, Lovisetti G. Open supracondylar-intercondylar fractures of the femur treatment with Taylor spatial frame. J Orthop Trauma. 2017;31:546–53.CrossRef Sala F, Thabet AM, Capitani P, Bove F, Abdelgawad AA, Lovisetti G. Open supracondylar-intercondylar fractures of the femur treatment with Taylor spatial frame. J Orthop Trauma. 2017;31:546–53.CrossRef
11.
go back to reference Lim JA, Thahir A, Zhou AK, Girish M, Krkovic M. Definitive management of open pilon fractures with fine wire fixation. Injury. 2020;51:2717–22.CrossRef Lim JA, Thahir A, Zhou AK, Girish M, Krkovic M. Definitive management of open pilon fractures with fine wire fixation. Injury. 2020;51:2717–22.CrossRef
12.
go back to reference Henderson DJ, Barron E, Hadland Y, Sharma HK. Functional outcomes after tibial shaft fractures treated using the Taylor spatial frame. J Orthop Trauma. 2015;29:e54–9.CrossRef Henderson DJ, Barron E, Hadland Y, Sharma HK. Functional outcomes after tibial shaft fractures treated using the Taylor spatial frame. J Orthop Trauma. 2015;29:e54–9.CrossRef
13.
go back to reference Koo TK, Mak AF. A knowledge-based computer-aided system for closed diaphyseal fracture reduction. Clin Biomech (Bristol, Avon). 2007;22:884–93.CrossRef Koo TK, Mak AF. A knowledge-based computer-aided system for closed diaphyseal fracture reduction. Clin Biomech (Bristol, Avon). 2007;22:884–93.CrossRef
14.
go back to reference Johner R, Wruhs O. Classification of tibial shaft fractures and correlation with results after rigid internal fixation. Clin Orthop Relat Res. 1983:7–25. Johner R, Wruhs O. Classification of tibial shaft fractures and correlation with results after rigid internal fixation. Clin Orthop Relat Res. 1983:7–25.
15.
go back to reference Gantsoudes GD, Fragomen AT, Rozbruch SR. Intraoperative measurement of mounting parameters for the Taylor spatial frame. J Orthop Trauma. 2010;24:258–62.CrossRef Gantsoudes GD, Fragomen AT, Rozbruch SR. Intraoperative measurement of mounting parameters for the Taylor spatial frame. J Orthop Trauma. 2010;24:258–62.CrossRef
16.
go back to reference Ilizarov GA. The principles of the Ilizarov method. Bull Hosp Jt Dis Orthop Inst. 1988;48:1–11.PubMed Ilizarov GA. The principles of the Ilizarov method. Bull Hosp Jt Dis Orthop Inst. 1988;48:1–11.PubMed
17.
go back to reference Saw A, Phang ZH, Alrasheed MK, Gunalan R, Albaker MZ, Shanmugam R. Gradual correction of proximal tibia deformity for Blount disease in adolescent and young adults. J Orthop Surg (Hong Kong). 2019;27:615534275.CrossRef Saw A, Phang ZH, Alrasheed MK, Gunalan R, Albaker MZ, Shanmugam R. Gradual correction of proximal tibia deformity for Blount disease in adolescent and young adults. J Orthop Surg (Hong Kong). 2019;27:615534275.CrossRef
18.
go back to reference Iobst CA. Hexapod external fixation of tibia fractures in children. J Pediatr Orthop. 2016;36(Suppl 1):S24–8.CrossRef Iobst CA. Hexapod external fixation of tibia fractures in children. J Pediatr Orthop. 2016;36(Suppl 1):S24–8.CrossRef
19.
go back to reference Abuomira IE, Sala F, Elbatrawy Y, Lovisetti G, Alati S, Capitani D. Distraction osteogenesis for tibial nonunion with bone loss using combined Ilizarov and Taylor spatial frames versus a conventional circular frame. Strategies Trauma Limb Reconstr. 2016;11:153–9.CrossRef Abuomira IE, Sala F, Elbatrawy Y, Lovisetti G, Alati S, Capitani D. Distraction osteogenesis for tibial nonunion with bone loss using combined Ilizarov and Taylor spatial frames versus a conventional circular frame. Strategies Trauma Limb Reconstr. 2016;11:153–9.CrossRef
20.
go back to reference Ordas-Bayon A, Logan K, Garg P, Peat F, Krkovic M. Ankle arthrodesis using the Taylor spatial frame for the treatment of infection, extruded talus and complex pilon fractures. Injury. 2021;52:1028–37.CrossRef Ordas-Bayon A, Logan K, Garg P, Peat F, Krkovic M. Ankle arthrodesis using the Taylor spatial frame for the treatment of infection, extruded talus and complex pilon fractures. Injury. 2021;52:1028–37.CrossRef
21.
go back to reference Rogers MJ, McFadyen I, Livingstone JA, Monsell F, Jackson M, Atkins RM. Computer hexapod assisted orthopaedic surgery (CHAOS) in the correction of long bone fracture and deformity. J Orthop Trauma. 2007;21:337–42.CrossRef Rogers MJ, McFadyen I, Livingstone JA, Monsell F, Jackson M, Atkins RM. Computer hexapod assisted orthopaedic surgery (CHAOS) in the correction of long bone fracture and deformity. J Orthop Trauma. 2007;21:337–42.CrossRef
22.
go back to reference Park DH, Bradish CF. An intraoperative method of calculating the mounting parameters for the Taylor spatial frame using the image intensifier. Ann R Coll Surg Engl. 2011;93:260–1.CrossRef Park DH, Bradish CF. An intraoperative method of calculating the mounting parameters for the Taylor spatial frame using the image intensifier. Ann R Coll Surg Engl. 2011;93:260–1.CrossRef
23.
go back to reference Kucukkaya M, Karakoyun O, Armagan R, Kuzgun U. Calculating the mounting parameters for Taylor spatial frame correction using computed tomography. J Orthop Trauma. 2011;25:449–52.CrossRef Kucukkaya M, Karakoyun O, Armagan R, Kuzgun U. Calculating the mounting parameters for Taylor spatial frame correction using computed tomography. J Orthop Trauma. 2011;25:449–52.CrossRef
24.
go back to reference Kanellopoulos AD, Mavrogenis AF, Kanellopoulos ND, Magnissalis EA, Papagelopoulos PJ. A guide frame for the Taylor spatial frame. J Orthop Trauma. 2009;23:537–40.CrossRef Kanellopoulos AD, Mavrogenis AF, Kanellopoulos ND, Magnissalis EA, Papagelopoulos PJ. A guide frame for the Taylor spatial frame. J Orthop Trauma. 2009;23:537–40.CrossRef
25.
go back to reference Deakin DE, Rolands T, Taylor A. A frame-mounted X-ray guide for the Taylor spatial frame. Ann R Coll Surg Engl. 2007;89:729.CrossRef Deakin DE, Rolands T, Taylor A. A frame-mounted X-ray guide for the Taylor spatial frame. Ann R Coll Surg Engl. 2007;89:729.CrossRef
26.
go back to reference Liu Y, Yushan M, Liu Z, Liu J, Ma C, Yusufu A. Application of elliptic registration and three-dimensional reconstruction in the postoperative measurement of Taylor spatial frame parameters. Injury. 2020;51:2975–80.CrossRef Liu Y, Yushan M, Liu Z, Liu J, Ma C, Yusufu A. Application of elliptic registration and three-dimensional reconstruction in the postoperative measurement of Taylor spatial frame parameters. Injury. 2020;51:2975–80.CrossRef
27.
go back to reference Wright J, Sabah SA, Patel S, Spence G. The silhouette technique: improving post-operative radiographs for planning of correction with a hexapod external fixator. Strategies Trauma Limb Reconstr. 2017;12:127–31.CrossRef Wright J, Sabah SA, Patel S, Spence G. The silhouette technique: improving post-operative radiographs for planning of correction with a hexapod external fixator. Strategies Trauma Limb Reconstr. 2017;12:127–31.CrossRef
28.
go back to reference Ahrend MD, Finger F, Grunwald L, Keller G, Baumgartner H. Improving the accuracy of patient positioning for long-leg radiographs using a Taylor spatial frame mounted rotation rod. Arch Orthop Trauma Surg. 2021;141:55–61.CrossRef Ahrend MD, Finger F, Grunwald L, Keller G, Baumgartner H. Improving the accuracy of patient positioning for long-leg radiographs using a Taylor spatial frame mounted rotation rod. Arch Orthop Trauma Surg. 2021;141:55–61.CrossRef
29.
go back to reference Al-Uzri M, Thahir A, Abdulkarim A, Krkovic M. Improving radiographic imaging for circular frames: the Cambridge experience. Arch Orthop Trauma Surg. 2020;140:1965–70.CrossRef Al-Uzri M, Thahir A, Abdulkarim A, Krkovic M. Improving radiographic imaging for circular frames: the Cambridge experience. Arch Orthop Trauma Surg. 2020;140:1965–70.CrossRef
30.
go back to reference Liu Y, Liu K, Cai F, Zhang T, Yusufu A. Improving postoperative radiographs for the parameter measurement of hexapod external fixator using an additional foot ring. J Orthop Surg Res. 2021;16:668.CrossRef Liu Y, Liu K, Cai F, Zhang T, Yusufu A. Improving postoperative radiographs for the parameter measurement of hexapod external fixator using an additional foot ring. J Orthop Surg Res. 2021;16:668.CrossRef
31.
go back to reference Gessmann J, Frieler S, Konigshausen M, Schildhauer TA, Hanusrichter Y, Seybold D, et al. Accuracy of radiographic measurement techniques for the Taylor spatial frame mounting parameters. BMC Musculoskelet Disord. 2021;22:284.CrossRef Gessmann J, Frieler S, Konigshausen M, Schildhauer TA, Hanusrichter Y, Seybold D, et al. Accuracy of radiographic measurement techniques for the Taylor spatial frame mounting parameters. BMC Musculoskelet Disord. 2021;22:284.CrossRef
Metadata
Title
Staged correction trajectory with hexapod external fixator for the satisfactory reduction of long bone shaft fracture
Authors
Yanshi Liu
Fei Wang
Kai Liu
Feiyu Cai
Xingpeng Zhang
Hong Li
Tao Zhang
Aihemaitijiang Yusufu
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2022
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-022-05172-5

Other articles of this Issue 1/2022

BMC Musculoskeletal Disorders 1/2022 Go to the issue