Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 10/2017

01-10-2017 | Trauma Surgery

Exposure of medical staff to radiation during osteosynthesis of proximal femoral fracture: descriptive analysis and comparison of different devices

Authors: Cédric Siedlecki, Rémi Gauthé, André Gillibert, Kevin Bellenger, Xavier Roussignol, Mourad Ould-Slimane

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 10/2017

Login to get access

Abstract

Background

The use of fluoroscopy is necessary during proximal femoral fracture (PFF) osteosynthesis. The frequency of these procedures justifies a description of radiation exposure and comparisons between different techniques and between the different surgical team members.

Methods

This observational prospective and comparative study includes a series of 68 patients with PFF receiving osteosynthesis. Radiation exposure was assessed for all members of the operating team. The radiation dose measurements for the different members of the surgical team during PFF osteosynthesis were compared. The factors affecting the radiation dose were investigated.

Results

The mean active dosimeter readings for each operation were 7.39 µSv for the primary surgeon, 3.93 µSv for the assistant surgeon, 1.92 µSv for the instrument nurse, 1.25 µSv for the circulating nurse, and 0.64 µSv for the anaesthesiologist, respectively. Doses decreased significantly between these different members of the medical team (all p < 0.001). The dose also varied with patient age and BMI, as well as with fluoroscopy time and operating time, but not with type of fracture or type of osteosynthesis.

Conclusion

Medical staff receives significantly different doses depending on their position in relation to the radiation source. Operating time and fluoroscopy time are the modifiable factors that affect the radiation dose. The radiation doses received by the different members of the medical teams involved in proximal femur osteosynthesis procedures all fall below the doses recommended by the International Commission on Radiation Units and Measurements.
Literature
1.
go back to reference Müller LP, Suffner J, Wenda K et al (1998) Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29:461–468CrossRefPubMed Müller LP, Suffner J, Wenda K et al (1998) Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29:461–468CrossRefPubMed
2.
go back to reference Seagger R, Howell J, David H, Gregg-Smith S (2004) Prevention of secondary osteoporotic fractures–why are we ignoring the evidence? Injury 35:986–988CrossRefPubMed Seagger R, Howell J, David H, Gregg-Smith S (2004) Prevention of secondary osteoporotic fractures–why are we ignoring the evidence? Injury 35:986–988CrossRefPubMed
3.
go back to reference Benetos IS, Babis GC, Zoubos AB et al (2007) Factors affecting the risk of hip fractures. Injury 38:735–744CrossRefPubMed Benetos IS, Babis GC, Zoubos AB et al (2007) Factors affecting the risk of hip fractures. Injury 38:735–744CrossRefPubMed
4.
5.
go back to reference International Commission on Radiological Protection (2010) Radiological protection in fluoroscopically guided procedures outside the imaging department. ICRP Publication 117. Ann ICRP 40 International Commission on Radiological Protection (2010) Radiological protection in fluoroscopically guided procedures outside the imaging department. ICRP Publication 117. Ann ICRP 40
6.
go back to reference Alonso JA, Shaw DL, Maxwell A et al (2001) Scattered radiation during fixation of hip fractures. Is distance alone enough protection? J Bone Jt Surg Br 83:815–818CrossRef Alonso JA, Shaw DL, Maxwell A et al (2001) Scattered radiation during fixation of hip fractures. Is distance alone enough protection? J Bone Jt Surg Br 83:815–818CrossRef
7.
go back to reference Plourde G, Pancholy SB, Nolan J et al (2015) Radiation exposure in relation to the arterial access site used for diagnostic coronary angiography and percutaneous coronary intervention: a systematic review and meta-analysis. Lancet 386:2192–2203CrossRefPubMed Plourde G, Pancholy SB, Nolan J et al (2015) Radiation exposure in relation to the arterial access site used for diagnostic coronary angiography and percutaneous coronary intervention: a systematic review and meta-analysis. Lancet 386:2192–2203CrossRefPubMed
8.
go back to reference Sciahbasi A, Rigattieri S, Sarandrea A et al (2015) Operator radiation exposure during right or left transradial coronary angiography: a phantom study. Cardiovasc Revascularization Med 16:386–390CrossRef Sciahbasi A, Rigattieri S, Sarandrea A et al (2015) Operator radiation exposure during right or left transradial coronary angiography: a phantom study. Cardiovasc Revascularization Med 16:386–390CrossRef
9.
go back to reference Marsh JL, Slongo TF, Agel J et al (2007) Fracture and dislocation classification compendium—2007: orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21:S1–S133CrossRefPubMed Marsh JL, Slongo TF, Agel J et al (2007) Fracture and dislocation classification compendium—2007: orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21:S1–S133CrossRefPubMed
10.
go back to reference Sulieman A, Alzimami K, Habeeballa B et al (2014) Evaluation of occupational and patient radiation doses in orthopedic surgery. Appl Radiat Isot, Med Sulieman A, Alzimami K, Habeeballa B et al (2014) Evaluation of occupational and patient radiation doses in orthopedic surgery. Appl Radiat Isot, Med
11.
go back to reference Ramisetty NM, Pynsent PB, Abudu A (2005) Fracture of the femoral neck, the risk of serious underlying pathology. Injury 36:622–626CrossRefPubMed Ramisetty NM, Pynsent PB, Abudu A (2005) Fracture of the femoral neck, the risk of serious underlying pathology. Injury 36:622–626CrossRefPubMed
12.
go back to reference Cooper C, Campion G, Melton LJ (1992) Hip fractures in the elderly: a world-wide projection. Osteoporos Int 2:285–289CrossRefPubMed Cooper C, Campion G, Melton LJ (1992) Hip fractures in the elderly: a world-wide projection. Osteoporos Int 2:285–289CrossRefPubMed
13.
go back to reference Kesavachandran CN, Haamann F, Nienhaus A (2012) Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review. Eur J Med Res 17:28CrossRefPubMedPubMedCentral Kesavachandran CN, Haamann F, Nienhaus A (2012) Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review. Eur J Med Res 17:28CrossRefPubMedPubMedCentral
14.
go back to reference Johnell O, Kanis JA (2004) An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int 15:897–902CrossRefPubMed Johnell O, Kanis JA (2004) An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int 15:897–902CrossRefPubMed
15.
go back to reference Palácio EP, Ribeiro AA, Gavassi BM et al (2014) Exposure of the surgical team to ionizing radiation during orthopedic surgical procedures. Rev Bras Ortop 49:227–232CrossRefPubMedPubMedCentral Palácio EP, Ribeiro AA, Gavassi BM et al (2014) Exposure of the surgical team to ionizing radiation during orthopedic surgical procedures. Rev Bras Ortop 49:227–232CrossRefPubMedPubMedCentral
16.
go back to reference Elffors L (1998) Are osteoporotic fractures due to osteoporosis? Impacts of a frailty pandemic in an aging world. Aging Milan Italy 10:191–204 Elffors L (1998) Are osteoporotic fractures due to osteoporosis? Impacts of a frailty pandemic in an aging world. Aging Milan Italy 10:191–204
17.
18.
go back to reference Jablon S, Bailar JC (1980) The contribution of ionizing radiation to cancer mortality in the United States. Prev Med 9:219–226CrossRefPubMed Jablon S, Bailar JC (1980) The contribution of ionizing radiation to cancer mortality in the United States. Prev Med 9:219–226CrossRefPubMed
19.
go back to reference Khan IA, Kamalasekaran S, Fazal MA (2012) Risk of ionising radiation to trainee orthopaedic surgeons. Acta Orthop Belg 78:106–110PubMed Khan IA, Kamalasekaran S, Fazal MA (2012) Risk of ionising radiation to trainee orthopaedic surgeons. Acta Orthop Belg 78:106–110PubMed
20.
go back to reference Mastrangelo G, Fedeli U, Fadda E et al (2005) Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med Oxf Engl 55:498–500CrossRef Mastrangelo G, Fedeli U, Fadda E et al (2005) Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med Oxf Engl 55:498–500CrossRef
21.
go back to reference Moore C, Heeckt P (2011) Reducing radiation risk in orthopaedic trauma surgery. Bone Jt Sci 2:1–6 Moore C, Heeckt P (2011) Reducing radiation risk in orthopaedic trauma surgery. Bone Jt Sci 2:1–6
22.
go back to reference Abas AA, Rahman RA, Yahya N et al (2014) Occupational radiation exposure to anesthetists from fluoroscopic projections during orthopedic operative procedures. Clin Ter 165:e253–e257PubMed Abas AA, Rahman RA, Yahya N et al (2014) Occupational radiation exposure to anesthetists from fluoroscopic projections during orthopedic operative procedures. Clin Ter 165:e253–e257PubMed
23.
go back to reference Dalgleish S, Hince A, Finlayson DF (2015) Peri-operative radiation exposure: are overweight patients at increased risks? Injury 46:2448–2451CrossRefPubMed Dalgleish S, Hince A, Finlayson DF (2015) Peri-operative radiation exposure: are overweight patients at increased risks? Injury 46:2448–2451CrossRefPubMed
24.
go back to reference Blattert TR, Fill UA, Kunz E et al (2004) Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study. Arch Orthop Trauma Surg 124:659–664CrossRefPubMed Blattert TR, Fill UA, Kunz E et al (2004) Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study. Arch Orthop Trauma Surg 124:659–664CrossRefPubMed
25.
go back to reference Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: “how far away is far enough?”. J Orthop Trauma 11:392–398CrossRefPubMed Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: “how far away is far enough?”. J Orthop Trauma 11:392–398CrossRefPubMed
29.
go back to reference Richter P, Dehner C, Scheiderer B et al (2013) Emission of radiation in the orthopaedic operation room: a comprehensive review. OA Musculoskeletal Medicine 1:1–11CrossRef Richter P, Dehner C, Scheiderer B et al (2013) Emission of radiation in the orthopaedic operation room: a comprehensive review. OA Musculoskeletal Medicine 1:1–11CrossRef
30.
go back to reference Burns S, Thornton R, Dauer LT et al (2013) Leaded eyeglasses substantially reduce radiation exposure of the surgeon’s eyes during acquisition of typical fluoroscopic views of the hip and pelvis. J Bone Jt Surg Am 95:1307–1311CrossRef Burns S, Thornton R, Dauer LT et al (2013) Leaded eyeglasses substantially reduce radiation exposure of the surgeon’s eyes during acquisition of typical fluoroscopic views of the hip and pelvis. J Bone Jt Surg Am 95:1307–1311CrossRef
31.
go back to reference Roux A, Bronsard N, Blanchet N, de Peretti F (2011) Can fluoroscopy radiation exposure be measured in minimally invasive trauma surgery? Orthop Traumatol Surg Res OTSR 97:662–667CrossRefPubMed Roux A, Bronsard N, Blanchet N, de Peretti F (2011) Can fluoroscopy radiation exposure be measured in minimally invasive trauma surgery? Orthop Traumatol Surg Res OTSR 97:662–667CrossRefPubMed
32.
go back to reference Botchu R, Ravikumar K (2008) Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: effect of surgical experience. Indian J Orthop 42:471–473CrossRefPubMedPubMedCentral Botchu R, Ravikumar K (2008) Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: effect of surgical experience. Indian J Orthop 42:471–473CrossRefPubMedPubMedCentral
33.
go back to reference Riley SA (1989) Radiation exposure from fluoroscopy during orthopedic surgical procedures. Clin Orthop 248:257–260 Riley SA (1989) Radiation exposure from fluoroscopy during orthopedic surgical procedures. Clin Orthop 248:257–260
34.
go back to reference Kuon E, Weitmann K, Hoffmann W et al (2015) Multicenter long-term validation of a minicourse in radiation-reducing techniques in the catheterization laboratory. Am J Cardiol 115:367–373CrossRefPubMed Kuon E, Weitmann K, Hoffmann W et al (2015) Multicenter long-term validation of a minicourse in radiation-reducing techniques in the catheterization laboratory. Am J Cardiol 115:367–373CrossRefPubMed
36.
go back to reference Lee T, Shin SW, Choi D et al (1987) Risk factors of radiation dose in patients undergoing peripherally-inserted central catheter procedure using conventional angiography equipment and flat panel detector-based mobile C-arm fluoroscopy. Acta Radiol Stockh Swed 55:1234–1238. doi:10.1177/0284185113514221 Lee T, Shin SW, Choi D et al (1987) Risk factors of radiation dose in patients undergoing peripherally-inserted central catheter procedure using conventional angiography equipment and flat panel detector-based mobile C-arm fluoroscopy. Acta Radiol Stockh Swed 55:1234–1238. doi:10.​1177/​0284185113514221​
37.
go back to reference Esfandiari H, Amiri S, Lichti DD, Anglin C (2016) A fast, accurate and closed-form method for pose recognition of an intramedullary nail using a tracked C-arm. Int J Comput Assist Radiol Surg 11:621–633. doi:10.1007/s11548-015-1294-y CrossRefPubMed Esfandiari H, Amiri S, Lichti DD, Anglin C (2016) A fast, accurate and closed-form method for pose recognition of an intramedullary nail using a tracked C-arm. Int J Comput Assist Radiol Surg 11:621–633. doi:10.​1007/​s11548-015-1294-y CrossRefPubMed
38.
go back to reference Khoury A, Liebergall M, Weil Y, Mosheiff R (2007) Computerized fluoroscopic-based navigation-assisted intramedullary nailing. Am J Orthop Belle Mead NJ 36:582–585PubMed Khoury A, Liebergall M, Weil Y, Mosheiff R (2007) Computerized fluoroscopic-based navigation-assisted intramedullary nailing. Am J Orthop Belle Mead NJ 36:582–585PubMed
Metadata
Title
Exposure of medical staff to radiation during osteosynthesis of proximal femoral fracture: descriptive analysis and comparison of different devices
Authors
Cédric Siedlecki
Rémi Gauthé
André Gillibert
Kevin Bellenger
Xavier Roussignol
Mourad Ould-Slimane
Publication date
01-10-2017
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 10/2017
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-017-2761-4