Skip to main content
Top
Published in: Hernia 3/2007

01-06-2007 | Original Article

Experimental comparison of type of Tissucol dilution and composite mesh (Parietex) for laparoscopic repair of groin and abdominal hernia: observational study conducted in a university laboratory

Authors: Stefano Olmi, Alessandro Addis, Cinzia Domeneghini, Alberto Scaini, Enrico Croce

Published in: Hernia | Issue 3/2007

Login to get access

Abstract

Purpose

The primary objective of this observational study was to determine the best possible dilution of fibrin glue (Tissucol) to employ for prosthesis fixing in laparoscopic treatment of abdominal wall defects and, secondly, to assess its feasibility and safety.

Materials and methods

This study was carried out in a university experimental animal laboratory in accordance with all international laws, ethics regulations and quality criteria associated with animal experiments. The tests were carried out on two pigs, using four samples of mesh (Parietex). All meshes were fixed using two different Tissucol dilutions (standard with distilled water and that with calcium chloride). Follow-up evaluations were at 15 days after 30 days, with the latter consisting of traction tests and a biopsy for histological analysis.

Results

No post-operative complications were observed. The collagen-coated polyester meshes showed 0% adhesions, and reperitonealization had ensued after 15 days. We saw no shrinkage or migration of any of the meshes. Histopathological analyses confirmed a greater stability, greater tissue integration and the largest number of fibroblasts in meshes fixed with a 1/10 Tissucol dilution without calcium chloride.

Conclusions

This observational study using animals showed that the 1/10 standard dilution – not that with calcium chloride – provided the best fixation and integration and prevented the formation of intraperitoneal adhesions, provided a hydrophilic collagen film-covered mesh was used.
Literature
1.
go back to reference Canonico S, Sciaudone G, Pacifico F, Santoriello A (1999) Inguinal hernia repair in patients with coagulation problems: prevention of postoperative bleeding with human fibrin glue. Surgery 125:315–317PubMed Canonico S, Sciaudone G, Pacifico F, Santoriello A (1999) Inguinal hernia repair in patients with coagulation problems: prevention of postoperative bleeding with human fibrin glue. Surgery 125:315–317PubMed
2.
go back to reference Carbajo MA, Martin del Olmo JC, Blanco JI, de la Cuesta C, Toledano M, Martin F, Vaquero C, Inglada L (1999) Laparoscopic treatment vs open surgery in the solution of major incisional and abdominal wall hernias with mesh. Surg Endosc 13:250–252PubMedCrossRef Carbajo MA, Martin del Olmo JC, Blanco JI, de la Cuesta C, Toledano M, Martin F, Vaquero C, Inglada L (1999) Laparoscopic treatment vs open surgery in the solution of major incisional and abdominal wall hernias with mesh. Surg Endosc 13:250–252PubMedCrossRef
4.
go back to reference Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25PubMedCrossRef Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25PubMedCrossRef
5.
go back to reference Novik B, Hagedorn S, Mork U-B, Dahlin K, Skullman S, Dalenback J (2006) Fibrin glue for securing the mesh in laparoscopic totally extraperitoneal inguinal hernia repair. A study with a 40-month prospective follow-up period. Surg Endosc 20:462–467PubMedCrossRef Novik B, Hagedorn S, Mork U-B, Dahlin K, Skullman S, Dalenback J (2006) Fibrin glue for securing the mesh in laparoscopic totally extraperitoneal inguinal hernia repair. A study with a 40-month prospective follow-up period. Surg Endosc 20:462–467PubMedCrossRef
6.
go back to reference Topart P, Vandenbroucke F, Lozac’h P (2005). Tisseel versus tack staples as mesh fixation in totally extraperitoneal laparoscopic repair of groin hernias. A retrospective analysis. Surg Endosc 19:724–727PubMedCrossRef Topart P, Vandenbroucke F, Lozac’h P (2005). Tisseel versus tack staples as mesh fixation in totally extraperitoneal laparoscopic repair of groin hernias. A retrospective analysis. Surg Endosc 19:724–727PubMedCrossRef
7.
go back to reference Redl H (2004) History of tissue adhesives. In: Saltz R, Toriumi DM (eds) Tissue glues in cosmetic surgery. Quality Medical, St Louis, Mo., pp 3–27 Redl H (2004) History of tissue adhesives. In: Saltz R, Toriumi DM (eds) Tissue glues in cosmetic surgery. Quality Medical, St Louis, Mo., pp 3–27
8.
9.
go back to reference Grossman JA, Capraro PA, Burneikis V (2001) Minimizing complications in the use of fibrin sealant in aesthetic facial procedure. Aesthet Surg J 21:32–39CrossRefPubMed Grossman JA, Capraro PA, Burneikis V (2001) Minimizing complications in the use of fibrin sealant in aesthetic facial procedure. Aesthet Surg J 21:32–39CrossRefPubMed
10.
go back to reference Bagot D’Arc M, Daculsi G (2003) Micro macroporous biphasic ceramics and fibrin sealant as a moldable material for bone reconstruction in chronic otitis media surgery: a 15 year experience. J Mater Sci Mater Med 14:229–233PubMedCrossRef Bagot D’Arc M, Daculsi G (2003) Micro macroporous biphasic ceramics and fibrin sealant as a moldable material for bone reconstruction in chronic otitis media surgery: a 15 year experience. J Mater Sci Mater Med 14:229–233PubMedCrossRef
11.
go back to reference Amrani DL, Di Orio JP, Delmotte Y (2001) Wound healing: role of commercial fibrin sealants. Ann N Y Acad Sci 936:566–579PubMedCrossRef Amrani DL, Di Orio JP, Delmotte Y (2001) Wound healing: role of commercial fibrin sealants. Ann N Y Acad Sci 936:566–579PubMedCrossRef
12.
go back to reference Sasaki GH, Mirzai T, Potyondy L, Smith M (2003) In vivo use of human fibrin glue under the subperiosteal and subcutaneous planes in Holtzman rats. Aesthet Surg J 23:1–6 Sasaki GH, Mirzai T, Potyondy L, Smith M (2003) In vivo use of human fibrin glue under the subperiosteal and subcutaneous planes in Holtzman rats. Aesthet Surg J 23:1–6
13.
go back to reference Corrente G, Abundo R, Cardaropoli D et al (2000) Long term evaluation of osseointegrated implants in regenerated and nonregenerated bone. Int J Periodont Rest 20:391 Corrente G, Abundo R, Cardaropoli D et al (2000) Long term evaluation of osseointegrated implants in regenerated and nonregenerated bone. Int J Periodont Rest 20:391
14.
go back to reference Goessl A, Redl H (2004) Optimized thrombin dilution protocol for a slowly setting fibrin sealant in surgery. Eur Surg 37/1:1–9 Goessl A, Redl H (2004) Optimized thrombin dilution protocol for a slowly setting fibrin sealant in surgery. Eur Surg 37/1:1–9
15.
go back to reference Dinges HP, Redl H, Thurnher M, Schiesser A, Schlag G (1986) Morphometric studies on wound healing after systemic administration of adriamycin and local application of fibrin sealant. Pathol Res Pract 181:745–754 Dinges HP, Redl H, Thurnher M, Schiesser A, Schlag G (1986) Morphometric studies on wound healing after systemic administration of adriamycin and local application of fibrin sealant. Pathol Res Pract 181:745–754
16.
go back to reference Fèrnandez Lobato R, Garcia Septiem J, Ortega Deballon P, Martin Lucas FJ, Ruiz deAdana JC, Limones Esteban M (2001) Tissucol application in dermolipectomy and incisional hernia repair. Int Surg 86:240–245PubMed Fèrnandez Lobato R, Garcia Septiem J, Ortega Deballon P, Martin Lucas FJ, Ruiz deAdana JC, Limones Esteban M (2001) Tissucol application in dermolipectomy and incisional hernia repair. Int Surg 86:240–245PubMed
Metadata
Title
Experimental comparison of type of Tissucol dilution and composite mesh (Parietex) for laparoscopic repair of groin and abdominal hernia: observational study conducted in a university laboratory
Authors
Stefano Olmi
Alessandro Addis
Cinzia Domeneghini
Alberto Scaini
Enrico Croce
Publication date
01-06-2007
Publisher
Springer-Verlag
Published in
Hernia / Issue 3/2007
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-007-0199-2

Other articles of this Issue 3/2007

Hernia 3/2007 Go to the issue