Ex vivo water exchange performance and short-term clinical feasibility assessment of newly developed heat and moisture exchangers for pulmonary rehabilitation after total laryngectomy

Authors: Cindy van den Boer, Sara H. Muller, Andrew D. Vincent, Klaus Züchner, Michiel W. M. van den Brekel, Frans J. M. Hilgers

Published in: European Archives of Oto-Rhino-Laryngology | Issue 2/2014

Login to get access

Abstract

Laryngectomized patients suffer from respiratory complaints due to insufficient warming and humidification of inspired air in the upper respiratory tract. Improvement of pulmonary humidification with significant reduction of pulmonary complaints is achieved by the application of a heat and moisture exchanger (HME) over the tracheostoma. The aim of this study was to determine whether the new Provox HMEs (XM-HME and XF-HME) have a better water exchange performance than their predecessors (R-HME and L-HME, respectively; Atos Medical, Hörby, Sweden). The other aim was to assess the short-term clinical feasibility of these HMEs. The XM-HME and XF-HME were weighed at the end of inspiration and at the end of expiration at different breathing volumes produced by a healthy volunteer. The associations between weight changes, breathing volume and absolute humidity were determined using both linear and non-linear mixed effects models. Study-specific questionnaires and tally sheets were used in the clinical feasibility study. The weight change of the XM-HME is 3.6 mg, this is significantly higher than that of the R-HME (2.0 mg). The weight change of the XF-HME (2.0 mg) was not significantly higher than that of the L-HME (1.8 mg). The absolute humidity values of both XM- and XF-HME were significantly higher than that of their predecessors. The clinical feasibility study did not reveal any practical problems over the course of 3 weeks. The XM-HME has a significantly better water exchange performance than its predecessor (R-HME). Both newly designed HMEs did succeed in the clinical feasibility study.
Appendix
Available only for authorised users
Literature
1.
go back to reference Branson RD (1999) Humidification for patients with artificial airways. Respir Care 44(6):630–641 Branson RD (1999) Humidification for patients with artificial airways. Respir Care 44(6):630–641
2.
go back to reference Cole P (1953) Temperature and humidity of respiratory air. J Physiol 122(Suppl):51PPubMed Cole P (1953) Temperature and humidity of respiratory air. J Physiol 122(Suppl):51PPubMed
3.
go back to reference Hilgers FJ, Ackerstaff AH, Aaronson NK, Schouwenburg PF, van Zandwijk N (1990) Physical and psychosocial consequences of total laryngectomy. Clin Otolaryngol Allied Sci 15(5):421–425PubMedCrossRef Hilgers FJ, Ackerstaff AH, Aaronson NK, Schouwenburg PF, van Zandwijk N (1990) Physical and psychosocial consequences of total laryngectomy. Clin Otolaryngol Allied Sci 15(5):421–425PubMedCrossRef
4.
go back to reference Walker JE, Wells RE Jr, Merrill EW (1961) Heat and water exchange in the respiratory tract. Am J Med 30:259–267PubMedCrossRef Walker JE, Wells RE Jr, Merrill EW (1961) Heat and water exchange in the respiratory tract. Am J Med 30:259–267PubMedCrossRef
5.
go back to reference Ackerstaff AH, Hilgers FJ, Aaronson NK, Balm AJ, van Zandwijk N (1993) Improvements in respiratory and psychosocial functioning following total laryngectomy by the use of a heat and moisture exchanger. Ann Otol Rhinol Laryngol 102(11):878–883PubMed Ackerstaff AH, Hilgers FJ, Aaronson NK, Balm AJ, van Zandwijk N (1993) Improvements in respiratory and psychosocial functioning following total laryngectomy by the use of a heat and moisture exchanger. Ann Otol Rhinol Laryngol 102(11):878–883PubMed
6.
go back to reference Bien S, Okla S, As-Brooks CJ, Ackerstaff AH (2010) The effect of a heat and moisture exchanger (Provox HME) on pulmonary protection after total laryngectomy: a randomized controlled study. Eur Arch Otorhinolaryngol 267(3):429–435PubMedCentralPubMedCrossRef Bien S, Okla S, As-Brooks CJ, Ackerstaff AH (2010) The effect of a heat and moisture exchanger (Provox HME) on pulmonary protection after total laryngectomy: a randomized controlled study. Eur Arch Otorhinolaryngol 267(3):429–435PubMedCentralPubMedCrossRef
7.
go back to reference Dassonville O, Merol JC, Bozec A, Swierkosz F, Santini J, Chais A, Marcy PY, Giacchero P, Chamorey E, Poissonnet G (2011) Randomised, multi-centre study of the usefulness of the heat and moisture exchanger (Provox HME(R)) in laryngectomised patients. Eur Arch Otorhinolaryngol 268(11):1647–1654PubMedCrossRef Dassonville O, Merol JC, Bozec A, Swierkosz F, Santini J, Chais A, Marcy PY, Giacchero P, Chamorey E, Poissonnet G (2011) Randomised, multi-centre study of the usefulness of the heat and moisture exchanger (Provox HME(R)) in laryngectomised patients. Eur Arch Otorhinolaryngol 268(11):1647–1654PubMedCrossRef
8.
go back to reference Hilgers FJ, Aaronson NK, Ackerstaff AH, Schouwenburg PF, van Zandwikj N (1991) The influence of a heat and moisture exchanger (HME) on the respiratory symptoms after total laryngectomy. Clin Otolaryngol Allied Sci 16(2):152–156PubMedCrossRef Hilgers FJ, Aaronson NK, Ackerstaff AH, Schouwenburg PF, van Zandwikj N (1991) The influence of a heat and moisture exchanger (HME) on the respiratory symptoms after total laryngectomy. Clin Otolaryngol Allied Sci 16(2):152–156PubMedCrossRef
9.
go back to reference International Standards Organization (2001) Anaesthetic and respiratory equipment—heat and moisture exchangers (HMEs) for humidifying respired gases in humans—Part 1: HMEs for use with tracheostomized patients having minimal tidal volume of 250 ml (ISO 9360-2:2001) International Standards Organization (2001) Anaesthetic and respiratory equipment—heat and moisture exchangers (HMEs) for humidifying respired gases in humans—Part 1: HMEs for use with tracheostomized patients having minimal tidal volume of 250 ml (ISO 9360-2:2001)
10.
go back to reference Keck T, Durr J, Leiacker R, Rettinger G, Rozsasi A (2005) Tracheal climate in laryngectomees after use of a heat and moisture exchanger. Laryngoscope 115(3):534–537PubMedCrossRef Keck T, Durr J, Leiacker R, Rettinger G, Rozsasi A (2005) Tracheal climate in laryngectomees after use of a heat and moisture exchanger. Laryngoscope 115(3):534–537PubMedCrossRef
11.
go back to reference McRae RD, Jones AS, Young P, Hamilton J (1995) Resistance, humidity and temperature of the tracheal airway. Clin Otolaryngol Allied Sci 20(4):355–356PubMedCrossRef McRae RD, Jones AS, Young P, Hamilton J (1995) Resistance, humidity and temperature of the tracheal airway. Clin Otolaryngol Allied Sci 20(4):355–356PubMedCrossRef
12.
go back to reference Scheenstra RJ, Muller SH, Vincent A, Ackerstaff AH, Jacobi I, Hilgers FJ (2011) A new heat and moisture exchanger for laryngectomized patients: endotracheal temperature and humidity. Respir Care 56(5):604–611PubMedCrossRef Scheenstra RJ, Muller SH, Vincent A, Ackerstaff AH, Jacobi I, Hilgers FJ (2011) A new heat and moisture exchanger for laryngectomized patients: endotracheal temperature and humidity. Respir Care 56(5):604–611PubMedCrossRef
13.
go back to reference Zuur JK, Muller SH, de Jongh FH, van der Horst MJ, Shehata M, van Leeuwen J, Sinaasappel M, Hilgers FJ (2007) A newly developed tool for intra-tracheal temperature and humidity assessment in laryngectomized individuals: the airway climate explorer (ACE). Med Biol Eng Comput 45(8):737–745PubMedCentralPubMedCrossRef Zuur JK, Muller SH, de Jongh FH, van der Horst MJ, Shehata M, van Leeuwen J, Sinaasappel M, Hilgers FJ (2007) A newly developed tool for intra-tracheal temperature and humidity assessment in laryngectomized individuals: the airway climate explorer (ACE). Med Biol Eng Comput 45(8):737–745PubMedCentralPubMedCrossRef
14.
go back to reference Scheenstra RJ, Muller SH, Vincent A, Sinaasappel M, Zuur JK, Hilgers FJ (2009) Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability. Med Biol Eng Comput 47(7):773–782PubMedCentralPubMedCrossRef Scheenstra RJ, Muller SH, Vincent A, Sinaasappel M, Zuur JK, Hilgers FJ (2009) Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability. Med Biol Eng Comput 47(7):773–782PubMedCentralPubMedCrossRef
15.
go back to reference Van den Boer C, Muller SH, Vincent AD, Zuchner K, Van den Brekel MW, Hilgers FJ (2013) A novel, simplified ex vivo method for measuring water exchange performance of heat and moisture exchangers for tracheostomy application. Respir Care (In press) Van den Boer C, Muller SH, Vincent AD, Zuchner K, Van den Brekel MW, Hilgers FJ (2013) A novel, simplified ex vivo method for measuring water exchange performance of heat and moisture exchangers for tracheostomy application. Respir Care (In press)
16.
go back to reference Rathgeber J, Kahle G, Schulze T, Zuchner K (2000) Rapid measurement of water vapor partial pressure at the saturation point with a new hybrid humidity sensor. Biomed Tech (Berl) 45(10):288–292CrossRef Rathgeber J, Kahle G, Schulze T, Zuchner K (2000) Rapid measurement of water vapor partial pressure at the saturation point with a new hybrid humidity sensor. Biomed Tech (Berl) 45(10):288–292CrossRef
17.
go back to reference Zuur JK, Muller SH, Vincent A, Sinaasappel M, de Jongh FH, Hilgers FJ (2008) Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate. Head Neck 30(8):1072–1082PubMedCrossRef Zuur JK, Muller SH, Vincent A, Sinaasappel M, de Jongh FH, Hilgers FJ (2008) Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate. Head Neck 30(8):1072–1082PubMedCrossRef
18.
go back to reference Scheenstra RJ, Muller SH, Vincent A, Sinaasappel M, Hilgers FJ (2010) Influence of breathing resistance of heat and moisture exchangers on tracheal climate and breathing pattern in laryngectomized individuals. Head Neck 32(8):1069–1078PubMedCrossRef Scheenstra RJ, Muller SH, Vincent A, Sinaasappel M, Hilgers FJ (2010) Influence of breathing resistance of heat and moisture exchangers on tracheal climate and breathing pattern in laryngectomized individuals. Head Neck 32(8):1069–1078PubMedCrossRef
19.
go back to reference International Standards Organization (2000) Anaesthetic and respiratory equipment—heat and moisture exchangers (HMEs) for humidifying respired gases in humans—Part 1: HMEs for use with minimal tidal volume of 250 ml (ISO 9360-1:2000) International Standards Organization (2000) Anaesthetic and respiratory equipment—heat and moisture exchangers (HMEs) for humidifying respired gases in humans—Part 1: HMEs for use with minimal tidal volume of 250 ml (ISO 9360-1:2000)
Metadata
Title
Ex vivo water exchange performance and short-term clinical feasibility assessment of newly developed heat and moisture exchangers for pulmonary rehabilitation after total laryngectomy
Authors
Cindy van den Boer
Sara H. Muller
Andrew D. Vincent
Klaus Züchner
Michiel W. M. van den Brekel
Frans J. M. Hilgers
Publication date
01-02-2014
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 2/2014
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-013-2528-7

Other articles of this Issue 2/2014

European Archives of Oto-Rhino-Laryngology 2/2014 Go to the issue