Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2014

Open Access 01-12-2014 | Research article

Evidence-based support for S1 transpedicular screw entry point modification

Authors: Lukasz Kubaszewski, Andrzej Nowakowski, Jacek Kaczmarczyk

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2014

Login to get access

Abstract

Background

In the literature, ‘below and lateral to the superior S1 facet’ is defined as the basic technique for screw introduction. Until a recently published modification, no analysis for alternative starting point has been proposed nor evaluated, although some surgeons claim to use some modifications. In this study, we analyse the data from anatomical and radiological studies for optimal starting point in transpedicular S1 screw placement.

Methods

A Medline search for key word combination: sacrum, anatomy, pedicle, screws and bone density resulted in 26 publications relevant to the topic. After a review of literature, two articles were chosen, as those including the appropriate set of data. The data retrieved from the articles is used for the analysis. The spatial relation of S1 facet, pedicles and vertebral body with cortical thickness and bone density in normal, osteopenic and osteoporotic sacrum is analysed.

Results

Presented data advocates for more medial placement of the screws due to higher bone density and lower bone loss in osteoporosis. Medial shift of the starting point does not increase the risk of spinal canal perforation. Osteoarthritic changes within the facet can augment the posterior supporting point for screw. The facet angular orientation is similar to convergent screw trajectory.

Conclusions

Modified technique for S1 screw placement takes advantage of latest anatomical and clinical data. In our opinion, technique modification improves the reproducibility and may increase stability and the screws within the posterior cortex of the S1 vertebra. Further biomechanical and clinical study should be performed to prove its superiority to classical technique.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sevrain A, Aubin CE, Gharbi H, Wang X, Labelle H: Biomechanical evaluation of predictive parameters of progression in adolescent isthmic spondylolisthesis: a computer modeling and simulation study. Scoliosis. 2012, 7: 2-10.1186/1748-7161-7-2.PubMedCentralCrossRefPubMed Sevrain A, Aubin CE, Gharbi H, Wang X, Labelle H: Biomechanical evaluation of predictive parameters of progression in adolescent isthmic spondylolisthesis: a computer modeling and simulation study. Scoliosis. 2012, 7: 2-10.1186/1748-7161-7-2.PubMedCentralCrossRefPubMed
2.
go back to reference Harimaya K, Mishiro T, Lenke LG, Bridwell KH, Koester LA, Sides BA: Etiology and revision surgical strategies in failed lumbosacral fixation of adult spinal deformity constructs. Spine. 2011, 15: 1701-1710.CrossRef Harimaya K, Mishiro T, Lenke LG, Bridwell KH, Koester LA, Sides BA: Etiology and revision surgical strategies in failed lumbosacral fixation of adult spinal deformity constructs. Spine. 2011, 15: 1701-1710.CrossRef
3.
go back to reference Devlin VJ, Boachie-Adjei O, Bradford DS, Ogilvie JW, Transfeldt EE: Treatment of adult spinal deformity with fusion to the sacrum using CD instrumentation. J Spinal Disord. 1991, 4: 1-14.CrossRefPubMed Devlin VJ, Boachie-Adjei O, Bradford DS, Ogilvie JW, Transfeldt EE: Treatment of adult spinal deformity with fusion to the sacrum using CD instrumentation. J Spinal Disord. 1991, 4: 1-14.CrossRefPubMed
4.
go back to reference Odate S, Shikata J, Kimura H, Soeda T: Sacral fracture following instrumented lumbosacral fusion: analysis of risk factors from spinopelvic parameters. Spine. 2012, 38: 223-229.CrossRef Odate S, Shikata J, Kimura H, Soeda T: Sacral fracture following instrumented lumbosacral fusion: analysis of risk factors from spinopelvic parameters. Spine. 2012, 38: 223-229.CrossRef
5.
go back to reference Fleischer GD, Kim YJ, Ferrara LA, Freeman AL, Boachie-Adjei O: Biomechanical analysis of sacral screw strain and range of motion in long posterior spinal fixation constructs: effects of lumbosacral fixation strategies in reducing sacral screw strains. Spine. 2012, 37: 163-169. 10.1097/BRS.0b013e31822ce9a7.CrossRef Fleischer GD, Kim YJ, Ferrara LA, Freeman AL, Boachie-Adjei O: Biomechanical analysis of sacral screw strain and range of motion in long posterior spinal fixation constructs: effects of lumbosacral fixation strategies in reducing sacral screw strains. Spine. 2012, 37: 163-169. 10.1097/BRS.0b013e31822ce9a7.CrossRef
6.
go back to reference Kwan MK, Jeffry A, Chan CY, Saw LB: A radiological evaluation of the morphometry and safety of S1, S2 and S2-ilium screws in the Asian population using three dimensional computed tomography scan: an analysis of 180 pelvis. Surg Radiol Anat. 2012, 34: 217-227. 10.1007/s00276-011-0919-2.CrossRefPubMed Kwan MK, Jeffry A, Chan CY, Saw LB: A radiological evaluation of the morphometry and safety of S1, S2 and S2-ilium screws in the Asian population using three dimensional computed tomography scan: an analysis of 180 pelvis. Surg Radiol Anat. 2012, 34: 217-227. 10.1007/s00276-011-0919-2.CrossRefPubMed
7.
go back to reference St Clair S, Tan JS, Lieberman I: Oblique lumbar interbody fixation: a biomechanical study in human spines. J Spinal Disord Tech. 2012, 25: 183-189. 10.1097/BSD.0b013e318211fc6b.CrossRefPubMed St Clair S, Tan JS, Lieberman I: Oblique lumbar interbody fixation: a biomechanical study in human spines. J Spinal Disord Tech. 2012, 25: 183-189. 10.1097/BSD.0b013e318211fc6b.CrossRefPubMed
8.
go back to reference Shirzadi A, Birch K, Drazin D, Liu JC, Acosta F: Direct lateral interbody fusion (DLIF) at the lumbosacral junction L5-S1. J Clin Neurosci. 2012, 19: 1022-1025. 10.1016/j.jocn.2011.11.009.CrossRefPubMed Shirzadi A, Birch K, Drazin D, Liu JC, Acosta F: Direct lateral interbody fusion (DLIF) at the lumbosacral junction L5-S1. J Clin Neurosci. 2012, 19: 1022-1025. 10.1016/j.jocn.2011.11.009.CrossRefPubMed
9.
go back to reference Agarwala A, Bucklen B, Muzumdar A, Moldavsky M, Khalil S: Do facet screws provide the required stability in lumbar fixation? A biomechanical comparison of the Boucher technique and pedicular fixation in primary and circumferential fusions. Clin Biomech. 2012, 27: 64-70. 10.1016/j.clinbiomech.2011.07.007.CrossRef Agarwala A, Bucklen B, Muzumdar A, Moldavsky M, Khalil S: Do facet screws provide the required stability in lumbar fixation? A biomechanical comparison of the Boucher technique and pedicular fixation in primary and circumferential fusions. Clin Biomech. 2012, 27: 64-70. 10.1016/j.clinbiomech.2011.07.007.CrossRef
10.
go back to reference Margulies J, Floman Y, Farcy JP, Neuwirth M: Lumbosacral and Spinopelvic Fixation. 1996, Philadelphia: Lippincott-Raven, 325-327. Margulies J, Floman Y, Farcy JP, Neuwirth M: Lumbosacral and Spinopelvic Fixation. 1996, Philadelphia: Lippincott-Raven, 325-327.
11.
go back to reference Roy-Camille R, Saillant G, Mazel C: Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res. 1986, 203: 7-17.PubMed Roy-Camille R, Saillant G, Mazel C: Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res. 1986, 203: 7-17.PubMed
12.
go back to reference Smith SA, Abitbol JJ, Carlson GD, Anderson DR, Taggart KW, Garfin SR: The effects of depth of penetration, screw orientation, and bone density on sacral screw fixation. Spine. 1993, 18: 1006-1010. 10.1097/00007632-199306150-00009.CrossRefPubMed Smith SA, Abitbol JJ, Carlson GD, Anderson DR, Taggart KW, Garfin SR: The effects of depth of penetration, screw orientation, and bone density on sacral screw fixation. Spine. 1993, 18: 1006-1010. 10.1097/00007632-199306150-00009.CrossRefPubMed
13.
go back to reference Carlson GD, Abitbol JJ, Anderson DR, Krag MH, Kostuik JP, Woo SL, Garfin SR: Screw fixation in the human sacrum. An in vitro study of the biomechanics of fixation. Spine. 1992, 17 (Suppl 6): 196-203.CrossRef Carlson GD, Abitbol JJ, Anderson DR, Krag MH, Kostuik JP, Woo SL, Garfin SR: Screw fixation in the human sacrum. An in vitro study of the biomechanics of fixation. Spine. 1992, 17 (Suppl 6): 196-203.CrossRef
14.
go back to reference Esses SI, Botsford DJ, Huler RJ, Rauschning W: Surgical anatomy of the sacrum. A guide for rational screw fixation. Spine. 1991, 16 (Suppl 6): 283-288.CrossRef Esses SI, Botsford DJ, Huler RJ, Rauschning W: Surgical anatomy of the sacrum. A guide for rational screw fixation. Spine. 1991, 16 (Suppl 6): 283-288.CrossRef
15.
go back to reference Hassanein GH: Metric study of Egyptian sacrum for lumbo-sacral fixation procedures. Clin Anat. 2011, 24: 218-224. 10.1002/ca.21082.CrossRefPubMed Hassanein GH: Metric study of Egyptian sacrum for lumbo-sacral fixation procedures. Clin Anat. 2011, 24: 218-224. 10.1002/ca.21082.CrossRefPubMed
17.
go back to reference Kubaszewski L, Kaczmarczyk J, Nowakowski A: A modified technique of placing transpedicular screws into the S1 vertebrae - surgical technique note. Pol Orthop Traumatol. 2013, 78: 101-104.PubMed Kubaszewski L, Kaczmarczyk J, Nowakowski A: A modified technique of placing transpedicular screws into the S1 vertebrae - surgical technique note. Pol Orthop Traumatol. 2013, 78: 101-104.PubMed
18.
go back to reference Arman C, Naderi S, Kiray A, Aksu FT, Yilmaz HS, Tetik S, Korman E: The human sacrum and safe approaches for screw placement. J Clin Neurosci. 2009, 16: 1046-1049. 10.1016/j.jocn.2008.07.081.CrossRefPubMed Arman C, Naderi S, Kiray A, Aksu FT, Yilmaz HS, Tetik S, Korman E: The human sacrum and safe approaches for screw placement. J Clin Neurosci. 2009, 16: 1046-1049. 10.1016/j.jocn.2008.07.081.CrossRefPubMed
19.
go back to reference Richards AM, Coleman NW, Knight TA, Belkoff SM, Mears SC: Bone density and cortical thickness in normal, osteopenic, and osteoporotic sacra. J Osteoporos. 2010, 2010: 504078-PubMedCentralPubMed Richards AM, Coleman NW, Knight TA, Belkoff SM, Mears SC: Bone density and cortical thickness in normal, osteopenic, and osteoporotic sacra. J Osteoporos. 2010, 2010: 504078-PubMedCentralPubMed
20.
go back to reference Lehman RA, Kuklo TR, Belmont PJ, Andersen RC, Polly DW: Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: a biomechanical analysis. Spine. 2002, 15: 806-811.CrossRef Lehman RA, Kuklo TR, Belmont PJ, Andersen RC, Polly DW: Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: a biomechanical analysis. Spine. 2002, 15: 806-811.CrossRef
21.
go back to reference Luk KD, Chen L, Lu WW: A stronger bicortical sacral pedicle screw fixation through the S1 endplate: an in vitro cyclic loading and pull-out force evaluation. Spine. 2005, 30: 525-529. 10.1097/01.brs.0000154649.55589.bf.CrossRefPubMed Luk KD, Chen L, Lu WW: A stronger bicortical sacral pedicle screw fixation through the S1 endplate: an in vitro cyclic loading and pull-out force evaluation. Spine. 2005, 30: 525-529. 10.1097/01.brs.0000154649.55589.bf.CrossRefPubMed
22.
go back to reference Okutan O, Kaptanoglu E, Solaroglu I, Beskonakli E, Tekdemir I: Determination of the length of anteromedial screw trajectory by measuring interforaminal distance in the first sacral vertebra. Spine. 2004, 29: 1608-1611. 10.1097/01.BRS.0000132309.17578.B0.CrossRefPubMed Okutan O, Kaptanoglu E, Solaroglu I, Beskonakli E, Tekdemir I: Determination of the length of anteromedial screw trajectory by measuring interforaminal distance in the first sacral vertebra. Spine. 2004, 29: 1608-1611. 10.1097/01.BRS.0000132309.17578.B0.CrossRefPubMed
23.
go back to reference Fuentes JM, Benezech J, Bonnel F, Vlahovitch B: Osteosynthesis of the low lumbar spine and spondylolisthesis. Modification of the Scholner plate and pedicular screwing [abstract]. Neurochirurgie. 1985, 31: s513- Fuentes JM, Benezech J, Bonnel F, Vlahovitch B: Osteosynthesis of the low lumbar spine and spondylolisthesis. Modification of the Scholner plate and pedicular screwing [abstract]. Neurochirurgie. 1985, 31: s513-
Metadata
Title
Evidence-based support for S1 transpedicular screw entry point modification
Authors
Lukasz Kubaszewski
Andrzej Nowakowski
Jacek Kaczmarczyk
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2014
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/1749-799X-9-22

Other articles of this Issue 1/2014

Journal of Orthopaedic Surgery and Research 1/2014 Go to the issue