Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial

Authors: RC. Rouchy, A. Moreau-Gaudry, E. Chipon, S. Aubry, L. Pazart, B. Lapuyade, M. Durand, M. Hajjam, S. Pottier, B. Renard, R. Logier, X. Orry, A. Cherifi, E. Quehen, G. Kervio, O. Favelle, F. Patat, E. De Kerviler, C. Hughes, M. Medici, J. Ghelfi, A. Mounier, I. Bricault

Published in: Trials | Issue 1/2017

Login to get access

Abstract

Background

Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator’s instruments, meaning the position and progression of the instruments are visualised in real time on the patient’s images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region.

Methods/design

This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and (3) the irradiation dose delivered, with (4) subgroup analysis according to the expected difficulty of the procedure, as well as an evaluation of (5) the usability of the device.

Discussion

This trial addresses the lack of published high-level evidence studies in which navigation-assisted CT-guided interventional procedures are evaluated. This trial is important because it addresses the problems associated with conventional CT guidance and is particularly relevant because the number of interventional radiology procedures carried out in routine clinical practice is increasing.

Trial registration

ClinicalTrials.gov identifier: NCT01896219. Registered on 5 July 2013.
Appendix
Available only for authorised users
Literature
1.
go back to reference Ikeda K, Osaki Y, Nakanishi H, Nasu A, Kawamura Y, Jyoko K, et al. Recent progress in radiofrequency ablation therapy for hepatocellular carcinoma. Oncology. 2014;87 Suppl 1:73–7.CrossRefPubMed Ikeda K, Osaki Y, Nakanishi H, Nasu A, Kawamura Y, Jyoko K, et al. Recent progress in radiofrequency ablation therapy for hepatocellular carcinoma. Oncology. 2014;87 Suppl 1:73–7.CrossRefPubMed
2.
go back to reference Althoff CE, Bollow M, Feist E, Marticorena-Garcia SR, Eshed I, Diekhoff T, et al. CT-guided corticosteroid injection of the sacroiliac joints: quality assurance and standardized prospective evaluation of long-term effectiveness over six months. Clin Rheumatol. 2015;34:1079–84.CrossRefPubMed Althoff CE, Bollow M, Feist E, Marticorena-Garcia SR, Eshed I, Diekhoff T, et al. CT-guided corticosteroid injection of the sacroiliac joints: quality assurance and standardized prospective evaluation of long-term effectiveness over six months. Clin Rheumatol. 2015;34:1079–84.CrossRefPubMed
3.
go back to reference Arnolli MM, Hanumara NC, Franken M, Brouwer DM, Broeders IAMJ. An overview of systems for CT- and MRI-guided percutaneous needle placement in the thorax and abdomen. Int J Med Robot. 2015;11:458–75.CrossRefPubMed Arnolli MM, Hanumara NC, Franken M, Brouwer DM, Broeders IAMJ. An overview of systems for CT- and MRI-guided percutaneous needle placement in the thorax and abdomen. Int J Med Robot. 2015;11:458–75.CrossRefPubMed
4.
go back to reference Schubert T, Jacob AL, Pansini M, Liu D, Gutzeit A, Kos S. CT-guided interventions using a free-hand, optical tracking system: initial clinical experience. Cardiovasc Intervent Radiol. 2013;36:1055–62.CrossRefPubMed Schubert T, Jacob AL, Pansini M, Liu D, Gutzeit A, Kos S. CT-guided interventions using a free-hand, optical tracking system: initial clinical experience. Cardiovasc Intervent Radiol. 2013;36:1055–62.CrossRefPubMed
5.
go back to reference Grasso RF, Faiella E, Luppi G, Schena E, Giurazza F, Del Vescovo R, et al. Percutaneous lung biopsy: comparison between an augmented reality CT navigation system and standard CT-guided technique. Int J Comput Assist Radiol Surg. 2013;8:837–48.CrossRefPubMed Grasso RF, Faiella E, Luppi G, Schena E, Giurazza F, Del Vescovo R, et al. Percutaneous lung biopsy: comparison between an augmented reality CT navigation system and standard CT-guided technique. Int J Comput Assist Radiol Surg. 2013;8:837–48.CrossRefPubMed
6.
go back to reference Grand DJ, Atalay MA, Cronan JJ, Mayo-Smith WW, Dupuy DE. CT-guided percutaneous lung biopsy: comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients. Eur J Radiol. 2011;79:e133–6.CrossRefPubMed Grand DJ, Atalay MA, Cronan JJ, Mayo-Smith WW, Dupuy DE. CT-guided percutaneous lung biopsy: comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients. Eur J Radiol. 2011;79:e133–6.CrossRefPubMed
7.
go back to reference Gevenois PA, Sergent G, De Myttenaere M, Beernaerts A, Rocmans P. CT-guided percutaneous drainage of an anterior mediastinal abscess with a 16 F catheter. Eur Respir J. 1995;8:869–70.PubMed Gevenois PA, Sergent G, De Myttenaere M, Beernaerts A, Rocmans P. CT-guided percutaneous drainage of an anterior mediastinal abscess with a 16 F catheter. Eur Respir J. 1995;8:869–70.PubMed
8.
go back to reference Kinoshita F, Kato T, Sugiura K, Nishimura M, Kinoshita T, Hashimoto M, et al. CT-guided transthoracic needle biopsy using a puncture site-down positioning technique. AJR Am J Roentgenol. 2006;187:926–32.CrossRefPubMed Kinoshita F, Kato T, Sugiura K, Nishimura M, Kinoshita T, Hashimoto M, et al. CT-guided transthoracic needle biopsy using a puncture site-down positioning technique. AJR Am J Roentgenol. 2006;187:926–32.CrossRefPubMed
9.
go back to reference Thanos L, Poulou LS, Mailli L, Pomoni M, Kelekis DA. Image-guided radiofrequency ablation of a pancreatic tumor with a new triple spiral-shaped electrode. Cardiovasc Intervent Radiol. 2010;33:215–8.CrossRefPubMed Thanos L, Poulou LS, Mailli L, Pomoni M, Kelekis DA. Image-guided radiofrequency ablation of a pancreatic tumor with a new triple spiral-shaped electrode. Cardiovasc Intervent Radiol. 2010;33:215–8.CrossRefPubMed
10.
go back to reference Mukhtar KN, Mahmood SN, Umair SF. CT guided percutaneous renal biopsy versus ultrasound guided for obtaining adequate tissue. J Pak Med Assoc. 2012;62:880–2.PubMed Mukhtar KN, Mahmood SN, Umair SF. CT guided percutaneous renal biopsy versus ultrasound guided for obtaining adequate tissue. J Pak Med Assoc. 2012;62:880–2.PubMed
11.
go back to reference Rathmann N, Haeusler U, Diezler P, Weiss C, Kostrzewa M, Sadick M, et al. Evaluation of radiation exposure of medical staff during CT-guided interventions. J Am Coll Radiol. 2015;12:82–9.CrossRefPubMed Rathmann N, Haeusler U, Diezler P, Weiss C, Kostrzewa M, Sadick M, et al. Evaluation of radiation exposure of medical staff during CT-guided interventions. J Am Coll Radiol. 2015;12:82–9.CrossRefPubMed
12.
go back to reference Sainani NI, Arellano RS, Shyn PB, Gervais DA, Mueller PR, Silverman SG. The challenging image-guided abdominal mass biopsy: established and emerging techniques “if you can see it, you can biopsy it”. Abdom Imaging. 2013;38:672–96.CrossRefPubMed Sainani NI, Arellano RS, Shyn PB, Gervais DA, Mueller PR, Silverman SG. The challenging image-guided abdominal mass biopsy: established and emerging techniques “if you can see it, you can biopsy it”. Abdom Imaging. 2013;38:672–96.CrossRefPubMed
13.
go back to reference Slotkin EM, Patel PD, Suarez JC. Accuracy of fluoroscopic guided acetabular component positioning during direct anterior total hip arthroplasty. J Arthroplasty. 2015;30(9 Suppl):102–6.CrossRefPubMed Slotkin EM, Patel PD, Suarez JC. Accuracy of fluoroscopic guided acetabular component positioning during direct anterior total hip arthroplasty. J Arthroplasty. 2015;30(9 Suppl):102–6.CrossRefPubMed
14.
go back to reference Brandt G, Zimolong A, Carrat L, Merloz P, Staudte HW, Lavallée S, et al. CRIGOS: a compact robot for image-guided orthopedic surgery. IEEE Trans Inf Technol Biomed. 1999;3:252–60.CrossRefPubMed Brandt G, Zimolong A, Carrat L, Merloz P, Staudte HW, Lavallée S, et al. CRIGOS: a compact robot for image-guided orthopedic surgery. IEEE Trans Inf Technol Biomed. 1999;3:252–60.CrossRefPubMed
15.
go back to reference Brandt G, Radermacher K, Zimolong A, Rau G, Merloz P, Klos TV, et al. CRIGOS: development of a compact robot for image-guided orthopedic surgery [in German]. Orthopade. 2000;29:645–9.PubMed Brandt G, Radermacher K, Zimolong A, Rau G, Merloz P, Klos TV, et al. CRIGOS: development of a compact robot for image-guided orthopedic surgery [in German]. Orthopade. 2000;29:645–9.PubMed
17.
go back to reference Uruc V, Ozden R, Dogramacı Y, Kalacı A, Dikmen B, Yıldız OS, et al. The comparison of freehand fluoroscopic guidance and electromagnetic navigation for distal locking of intramedullary implants. Injury. 2013;44:863–6.CrossRefPubMed Uruc V, Ozden R, Dogramacı Y, Kalacı A, Dikmen B, Yıldız OS, et al. The comparison of freehand fluoroscopic guidance and electromagnetic navigation for distal locking of intramedullary implants. Injury. 2013;44:863–6.CrossRefPubMed
18.
go back to reference Weiner GM, Chivukula S, Chen CJ, Ding D, Engh JA, Amankulor N. Ommaya reservoir with ventricular catheter placement for chemotherapy with frameless and pinless electromagnetic surgical neuronavigation. Clin Neurol Neurosurg. 2015;130:61–6.CrossRefPubMed Weiner GM, Chivukula S, Chen CJ, Ding D, Engh JA, Amankulor N. Ommaya reservoir with ventricular catheter placement for chemotherapy with frameless and pinless electromagnetic surgical neuronavigation. Clin Neurol Neurosurg. 2015;130:61–6.CrossRefPubMed
19.
go back to reference Mahan M, Spetzler RF, Nakaji P. Electromagnetic stereotactic navigation for external ventricular drain placement in the intensive care unit. J Clin Neurosci. 2013;20:1718–22.CrossRefPubMed Mahan M, Spetzler RF, Nakaji P. Electromagnetic stereotactic navigation for external ventricular drain placement in the intensive care unit. J Clin Neurosci. 2013;20:1718–22.CrossRefPubMed
20.
go back to reference Chen MJ, Gu LX, Zhang WJ, Yang C, Dong MJ. Electromagnetic navigation-guided radiofrequency thermocoagulation in trigeminal neuralgia: technical note with three case reports. J Neurol Surg A Cent Eur Neurosurg. 2013;74:251–7.CrossRefPubMed Chen MJ, Gu LX, Zhang WJ, Yang C, Dong MJ. Electromagnetic navigation-guided radiofrequency thermocoagulation in trigeminal neuralgia: technical note with three case reports. J Neurol Surg A Cent Eur Neurosurg. 2013;74:251–7.CrossRefPubMed
21.
go back to reference Ko R, Soucy F, Denstedt JD, Razvi H. Percutaneous nephrolithotomy made easier: a practical guide, tips and tricks. BJU Int. 2008;101:535–9.CrossRefPubMed Ko R, Soucy F, Denstedt JD, Razvi H. Percutaneous nephrolithotomy made easier: a practical guide, tips and tricks. BJU Int. 2008;101:535–9.CrossRefPubMed
22.
go back to reference Chang CM, Fang KM, Huang TW, Wang CT, Cheng PW. Three-dimensional analysis of the surface registration accuracy of electromagnetic navigation systems in live endoscopic sinus surgery. Rhinology. 2013;51:343–8.PubMed Chang CM, Fang KM, Huang TW, Wang CT, Cheng PW. Three-dimensional analysis of the surface registration accuracy of electromagnetic navigation systems in live endoscopic sinus surgery. Rhinology. 2013;51:343–8.PubMed
23.
go back to reference Soyer P, Fargeaudou Y, Boudiaf M, Hamzi L, Rymer R. Percutaneous abdominopelvic interventional procedures using real-time CT fluoroscopy guidance at 21 mAs: an analysis of 99 consecutive cases [in French]. J Radiol. 2008;89:565–70.CrossRefPubMed Soyer P, Fargeaudou Y, Boudiaf M, Hamzi L, Rymer R. Percutaneous abdominopelvic interventional procedures using real-time CT fluoroscopy guidance at 21 mAs: an analysis of 99 consecutive cases [in French]. J Radiol. 2008;89:565–70.CrossRefPubMed
24.
go back to reference Prosch H, Stadler A, Schilling M, Bürklin S, Eisenhuber E, Schober E, et al. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose. Eur J Radiol. 2012;81:1029–33.CrossRefPubMed Prosch H, Stadler A, Schilling M, Bürklin S, Eisenhuber E, Schober E, et al. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose. Eur J Radiol. 2012;81:1029–33.CrossRefPubMed
25.
go back to reference Nagel M, Schmidt G, Petzold R, Kalender WA. A navigation system for minimally invasive CT-guided interventions. Med Image Comput Comput Assist Interv. 2005;8:33–40.PubMed Nagel M, Schmidt G, Petzold R, Kalender WA. A navigation system for minimally invasive CT-guided interventions. Med Image Comput Comput Assist Interv. 2005;8:33–40.PubMed
26.
go back to reference Bruners P, Penzkofer T, Nagel M, Elfring R, Gronloh N, Schmitz-Rode T, et al. Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results. Eur Radiol. 2009;19:990–4.CrossRefPubMed Bruners P, Penzkofer T, Nagel M, Elfring R, Gronloh N, Schmitz-Rode T, et al. Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results. Eur Radiol. 2009;19:990–4.CrossRefPubMed
27.
go back to reference Wallace MJ, Gupta S, Hicks ME. Out-of-plane computed-tomography-guided biopsy using a magnetic-field-based navigation system. Cardiovasc Intervent Radiol. 2006;29:108–13.CrossRefPubMed Wallace MJ, Gupta S, Hicks ME. Out-of-plane computed-tomography-guided biopsy using a magnetic-field-based navigation system. Cardiovasc Intervent Radiol. 2006;29:108–13.CrossRefPubMed
28.
go back to reference Moncharmont L, Moreau-Gaudry A, Medici M, Bricault I. Phantom evaluation of a navigation system for out-of-plane CT-guided puncture. Diagn Interv Imaging. 2015;96:531–6.CrossRefPubMed Moncharmont L, Moreau-Gaudry A, Medici M, Bricault I. Phantom evaluation of a navigation system for out-of-plane CT-guided puncture. Diagn Interv Imaging. 2015;96:531–6.CrossRefPubMed
29.
go back to reference Durand P, Moreau-Gaudry A, Silvent A-S, Frandon J, Chipon E, Médici M, et al. Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions: A prospective randomized clinical trial. PloS One. 2017;12:e0173751. Durand P, Moreau-Gaudry A, Silvent A-S, Frandon J, Chipon E, Médici M, et al. Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions: A prospective randomized clinical trial. PloS One. 2017;12:e0173751.
30.
go back to reference Sacks D, McClenny TE, Cardella JF, Lewis CA. Society of Interventional Radiology clinical practice guidelines. J Vasc Interv Radiol. 2003;14:S199–202.CrossRefPubMed Sacks D, McClenny TE, Cardella JF, Lewis CA. Society of Interventional Radiology clinical practice guidelines. J Vasc Interv Radiol. 2003;14:S199–202.CrossRefPubMed
31.
go back to reference Bakal CW, Sacks D, Burke DR, Cardella JF, Chopra PS, Dawson SL, et al. Quality improvement guidelines for adult percutaneous abscess and fluid drainage. J Vasc Interv Radiol. 2003;14:S223–5.CrossRefPubMed Bakal CW, Sacks D, Burke DR, Cardella JF, Chopra PS, Dawson SL, et al. Quality improvement guidelines for adult percutaneous abscess and fluid drainage. J Vasc Interv Radiol. 2003;14:S223–5.CrossRefPubMed
32.
go back to reference Cardella JF, Bakal CW, Bertino RE, Burke DR, Drooz A, Haskal Z, et al. Quality improvement guidelines for image-guided percutaneous biopsy in adults. J Vasc Interv Radiol. 2003;14:S227–30.CrossRefPubMed Cardella JF, Bakal CW, Bertino RE, Burke DR, Drooz A, Haskal Z, et al. Quality improvement guidelines for image-guided percutaneous biopsy in adults. J Vasc Interv Radiol. 2003;14:S227–30.CrossRefPubMed
33.
go back to reference Tomiyama N, Yasuhara Y, Nakajima Y, Adachi S, Arai Y, Kusumoto M, et al. CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan. Eur J Radiol. 2006;59:60–4.CrossRefPubMed Tomiyama N, Yasuhara Y, Nakajima Y, Adachi S, Arai Y, Kusumoto M, et al. CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan. Eur J Radiol. 2006;59:60–4.CrossRefPubMed
34.
go back to reference Newcombe RG. Interval estimation for the difference between independent proportions: comparison of eleven methods. Stat Med. 1998;17:873–90.CrossRefPubMed Newcombe RG. Interval estimation for the difference between independent proportions: comparison of eleven methods. Stat Med. 1998;17:873–90.CrossRefPubMed
35.
go back to reference Noether GE. Sample size determination for some common nonparametric tests. J Am Stat Assoc. 1987;82:645–7.CrossRef Noether GE. Sample size determination for some common nonparametric tests. J Am Stat Assoc. 1987;82:645–7.CrossRef
36.
go back to reference Walker E, Nowacki AS. Understanding equivalence and noninferiority testing. J Gen Intern Med. 2011;26:192–6.CrossRefPubMed Walker E, Nowacki AS. Understanding equivalence and noninferiority testing. J Gen Intern Med. 2011;26:192–6.CrossRefPubMed
Metadata
Title
Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial
Authors
RC. Rouchy
A. Moreau-Gaudry
E. Chipon
S. Aubry
L. Pazart
B. Lapuyade
M. Durand
M. Hajjam
S. Pottier
B. Renard
R. Logier
X. Orry
A. Cherifi
E. Quehen
G. Kervio
O. Favelle
F. Patat
E. De Kerviler
C. Hughes
M. Medici
J. Ghelfi
A. Mounier
I. Bricault
Publication date
01-12-2017
Publisher
BioMed Central
Published in
Trials / Issue 1/2017
Electronic ISSN: 1745-6215
DOI
https://doi.org/10.1186/s13063-017-2049-6

Other articles of this Issue 1/2017

Trials 1/2017 Go to the issue