Skip to main content
Top
Published in: Dysphagia 2/2011

01-06-2011 | Original Article

Evaluation of Swallowing Using 320-Detector-Row Multislice CT. Part I: Single- and Multiphase Volume Scanning for Three-dimensional Morphological and Kinematic Analysis

Authors: Naoko Fujii, Yoko Inamoto, Eiichi Saitoh, Mikoto Baba, Sumiko Okada, Satoshi Yoshioka, Toshiaki Nakai, Yoshihiro Ida, Kazuhiro Katada, Jeffrey B. Palmer

Published in: Dysphagia | Issue 2/2011

Login to get access

Abstract

A 320-detector-row multislice computed tomography (320-MSCT) scanner can acquire a volume data set covering a maximum range of 16 cm and can generate axial images 0.5-mm thick at 0.5-mm intervals. Three-dimensional (3D) images reconstructed from the thin axial slices include multiplanar reconstruction and 3D-CT. Single-phase 3D images are reconstructed from 0.175-s data, and multiphase 3D images are created in 29 phases at intervals of 0.1 s. Continuous replay of these 3D images produces four-dimensional moving images. In order to determine the feasibility of the morphologic and kinematic analyses of swallowing using 320-MSCT, single-phase volume scanning was performed on three patients and multiphase volume scanning was performed on one healthy volunteer. The single-phase 3D images clearly and accurately showed the structures involved in swallowing, and the multiphase 3D images were able to show the oral stage to the early esophageal stage of swallowing, allowing a kinematic analysis of swallowing. We developed a reclining chair that allows scanning to be performed with the subject in a semisitting position, which makes swallowing evaluation by 320-MSCT applicable not only to research on healthy swallowing but also to the clinical examination of dysphagia patients.
Literature
1.
go back to reference International Commission on Radiological Protection. Managing patient dose in multi-detector computed tomography (MDCT), ICRP Publication 102. Ann ICRP 2007;37(1). International Commission on Radiological Protection. Managing patient dose in multi-detector computed tomography (MDCT), ICRP Publication 102. Ann ICRP 2007;37(1).
2.
go back to reference Point SW, Horton KM, Bryan N, Cunningham ET Jr, Zinreich SJ. Cross-sectional imaging of dysphagia. In: Jones B, editor. Normal and abnormal swallowing: imaging in diagnosis and therapy. 2nd ed. New York: Springer-Verlag; 2003. p. 1139–65. Point SW, Horton KM, Bryan N, Cunningham ET Jr, Zinreich SJ. Cross-sectional imaging of dysphagia. In: Jones B, editor. Normal and abnormal swallowing: imaging in diagnosis and therapy. 2nd ed. New York: Springer-Verlag; 2003. p. 1139–65.
3.
go back to reference Flaherty RF, Seltzer S, Campbell T, Weisskoff RM, Gilbert RJ. Dynamic magnetic resonance imaging of vocal cord closure during deglutition. Gastroenterology. 1995;109:843–9.PubMedCrossRef Flaherty RF, Seltzer S, Campbell T, Weisskoff RM, Gilbert RJ. Dynamic magnetic resonance imaging of vocal cord closure during deglutition. Gastroenterology. 1995;109:843–9.PubMedCrossRef
4.
go back to reference Suto Y, Kamba M, Kato T. Technical note: dynamic analysis of the pharynx during swallowing using Turbo-FLASH magnetic resonance imaging combined with an oral positive contrast agent—a preliminary study. Br J Radiol. 1995;68:1099–102.PubMedCrossRef Suto Y, Kamba M, Kato T. Technical note: dynamic analysis of the pharynx during swallowing using Turbo-FLASH magnetic resonance imaging combined with an oral positive contrast agent—a preliminary study. Br J Radiol. 1995;68:1099–102.PubMedCrossRef
5.
go back to reference Gilbert RJ, Daftary S, Woo P, Seltzer S, Shapshay SM, Weisskoff RM. Echo-planar magnetic resonance imaging of deglutitive vocal fold closure: normal and pathologic patterns of displacement. Laryngoscope. 1996;106:568–72.PubMedCrossRef Gilbert RJ, Daftary S, Woo P, Seltzer S, Shapshay SM, Weisskoff RM. Echo-planar magnetic resonance imaging of deglutitive vocal fold closure: normal and pathologic patterns of displacement. Laryngoscope. 1996;106:568–72.PubMedCrossRef
6.
go back to reference Gilbert RJ, Daftary S, Campbell TA, Weisskoff RM. Patterns of lingual tissue deformation associated with bolus containment and propulsion during deglutition as determined by echo-planar MRI. J Magn Reson Imaging. 1998;8:554–60.PubMedCrossRef Gilbert RJ, Daftary S, Campbell TA, Weisskoff RM. Patterns of lingual tissue deformation associated with bolus containment and propulsion during deglutition as determined by echo-planar MRI. J Magn Reson Imaging. 1998;8:554–60.PubMedCrossRef
7.
go back to reference Foucart JM, Carpentier P, Pajoni D, Rabischong P, Pharaboz C. Kinetic magnetic resonance imaging analysis of swallowing: a new approach to pharyngeal function. Surg Radiol Anat. 1998;20:53–5.PubMedCrossRef Foucart JM, Carpentier P, Pajoni D, Rabischong P, Pharaboz C. Kinetic magnetic resonance imaging analysis of swallowing: a new approach to pharyngeal function. Surg Radiol Anat. 1998;20:53–5.PubMedCrossRef
8.
go back to reference Barkhausen J, Goyen M, von Winterfeld F, Lauenstein T, Arweiler-Harbeck D, Debatin JF. Visualization of swallowing using real-time TrueFISP MR fluoroscopy. Eur Radiol. 2002;12:129–33.PubMedCrossRef Barkhausen J, Goyen M, von Winterfeld F, Lauenstein T, Arweiler-Harbeck D, Debatin JF. Visualization of swallowing using real-time TrueFISP MR fluoroscopy. Eur Radiol. 2002;12:129–33.PubMedCrossRef
9.
go back to reference Kitano H, Asada Y, Hayashi K, Inoue H, Kitajima K. The evaluation of dysphagia following radical surgery for oral and pharyngeal carcinomas by cine-magnetic resonance imaging (Cine-MRI). Dysphagia. 2002;17:187–91.PubMedCrossRef Kitano H, Asada Y, Hayashi K, Inoue H, Kitajima K. The evaluation of dysphagia following radical surgery for oral and pharyngeal carcinomas by cine-magnetic resonance imaging (Cine-MRI). Dysphagia. 2002;17:187–91.PubMedCrossRef
10.
go back to reference Hartl DM, Albiter M, Kolb F, Luboinski B, Sigal R. Morphologic parameters of normal swallowing events using single-shot fast spin echo dynamic MRI. Dysphagia. 2003;18:255–62.PubMedCrossRef Hartl DM, Albiter M, Kolb F, Luboinski B, Sigal R. Morphologic parameters of normal swallowing events using single-shot fast spin echo dynamic MRI. Dysphagia. 2003;18:255–62.PubMedCrossRef
11.
go back to reference Karaçay S, Akin E, Sayin MO, Bulakbaşi N. Real time balanced turbo field echo Cine-MRI in the analysis of deglutition events and transit times. J Oral Rehabil. 2006;33:646–53.PubMedCrossRef Karaçay S, Akin E, Sayin MO, Bulakbaşi N. Real time balanced turbo field echo Cine-MRI in the analysis of deglutition events and transit times. J Oral Rehabil. 2006;33:646–53.PubMedCrossRef
12.
go back to reference Hartl DM, Kolb F, Bretagne E, Marandas P, Sigal R. Cine magnetic resonance imaging with single-shot fast spin echo for evaluation of dysphagia and aspiration. Dysphagia. 2006;21:156–62.PubMedCrossRef Hartl DM, Kolb F, Bretagne E, Marandas P, Sigal R. Cine magnetic resonance imaging with single-shot fast spin echo for evaluation of dysphagia and aspiration. Dysphagia. 2006;21:156–62.PubMedCrossRef
13.
go back to reference Breyer T, Echternach M, Arndt S, Richter B, Speck O, Schumacher M, et al. Dynamic magnetic resonance imaging of swallowing and laryngeal motion using parallel imaging at 3 T. Magn Reson Imaging. 2009;27:48–54.PubMedCrossRef Breyer T, Echternach M, Arndt S, Richter B, Speck O, Schumacher M, et al. Dynamic magnetic resonance imaging of swallowing and laryngeal motion using parallel imaging at 3 T. Magn Reson Imaging. 2009;27:48–54.PubMedCrossRef
14.
go back to reference Honda Y, Hata N. Dynamic imaging of swallowing in a seated position using open-configuration MRI. J Magn Reson Imaging. 2007;26:172–6.PubMedCrossRef Honda Y, Hata N. Dynamic imaging of swallowing in a seated position using open-configuration MRI. J Magn Reson Imaging. 2007;26:172–6.PubMedCrossRef
15.
go back to reference Ergun GA, Kahrilas PJ, Lin S, Logemann JA, Harig JM. Shape, volume, and content of the deglutitive pharyngeal chamber imaged by ultrafast computerized tomography. Gastroenterology. 1993;105:1396–403.PubMedCrossRef Ergun GA, Kahrilas PJ, Lin S, Logemann JA, Harig JM. Shape, volume, and content of the deglutitive pharyngeal chamber imaged by ultrafast computerized tomography. Gastroenterology. 1993;105:1396–403.PubMedCrossRef
16.
go back to reference Tsukamoto Y. CT study of closure of the hemipharynx with head rotation in a case of lateral medullary syndrome. Dysphagia. 2000;15:17–8.PubMed Tsukamoto Y. CT study of closure of the hemipharynx with head rotation in a case of lateral medullary syndrome. Dysphagia. 2000;15:17–8.PubMed
17.
go back to reference Takehara I, Chu J. Pharynx and oesophagus evaluation during the swallow using helical computerized tomography. Disabil Rehabil. 2004;26:733–8.PubMedCrossRef Takehara I, Chu J. Pharynx and oesophagus evaluation during the swallow using helical computerized tomography. Disabil Rehabil. 2004;26:733–8.PubMedCrossRef
18.
go back to reference Murayama K, Katada K, Nakane M, Toyama H, Anno H, Hayakawa M, et al. Whole-brain perfusion CT performed with a prototype 256-detector row CT system: initial experience. Radiology. 2009;250:202–11.PubMedCrossRef Murayama K, Katada K, Nakane M, Toyama H, Anno H, Hayakawa M, et al. Whole-brain perfusion CT performed with a prototype 256-detector row CT system: initial experience. Radiology. 2009;250:202–11.PubMedCrossRef
19.
go back to reference Rybicki FJ, Otero HJ, Steigner ML, Vorobiof G, Nallamshetty L, Mitsouras D, et al. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging. 2008;24:535–46.PubMedCrossRef Rybicki FJ, Otero HJ, Steigner ML, Vorobiof G, Nallamshetty L, Mitsouras D, et al. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging. 2008;24:535–46.PubMedCrossRef
20.
go back to reference Klingebiel R, Siebert E, Diekmann S, Wiener E, Masuhr F, Wagner M, et al. 4-D Imaging in cerebrovascular disorders by using 320-slice CT: feasibility and preliminary clinical experience. Acad Radiol. 2009;16:123–9.PubMedCrossRef Klingebiel R, Siebert E, Diekmann S, Wiener E, Masuhr F, Wagner M, et al. 4-D Imaging in cerebrovascular disorders by using 320-slice CT: feasibility and preliminary clinical experience. Acad Radiol. 2009;16:123–9.PubMedCrossRef
21.
go back to reference Hein PA, Romano VC, Lembcke A, May J, Rogalla P. Initial experience with a chest pain protocol using 320-slice volume MDCT. Eur Radiol. 2009;19:1148–55.PubMedCrossRef Hein PA, Romano VC, Lembcke A, May J, Rogalla P. Initial experience with a chest pain protocol using 320-slice volume MDCT. Eur Radiol. 2009;19:1148–55.PubMedCrossRef
22.
go back to reference Cunningham ET Jr, Jones B. Anatomical and physiological overview. In: Jones B, editor. Normal and abnormal swallowing: imaging in diagnosis and therapy. 2nd ed. New York: Springer-Verlag; 2003. p. 11–34. Cunningham ET Jr, Jones B. Anatomical and physiological overview. In: Jones B, editor. Normal and abnormal swallowing: imaging in diagnosis and therapy. 2nd ed. New York: Springer-Verlag; 2003. p. 11–34.
23.
go back to reference Saitoh E, Kimura A, Yamori S, Mori H, Izumi S, Chino N. Videofluorography in rehabilitation of dysphagia. Jpn J Rehabil Med. 1986;23:121–4. [in Japanese]. Saitoh E, Kimura A, Yamori S, Mori H, Izumi S, Chino N. Videofluorography in rehabilitation of dysphagia. Jpn J Rehabil Med. 1986;23:121–4. [in Japanese].
24.
go back to reference International Commission on Radiological Protection. Managing patient dose in computed tomography, ICRP Publication 87. Ann ICRP 2001;30(4). International Commission on Radiological Protection. Managing patient dose in computed tomography, ICRP Publication 87. Ann ICRP 2001;30(4).
25.
go back to reference Mahesh M, Gayler BW, Beck TJ. Radiation in videorecorded fluoroscopy. In: Jones B, editor. Normal and abnormal swallowing: imaging in diagnosis and therapy. 2nd ed. New York: Springer-Verlag; 2003. p. 1–9. Mahesh M, Gayler BW, Beck TJ. Radiation in videorecorded fluoroscopy. In: Jones B, editor. Normal and abnormal swallowing: imaging in diagnosis and therapy. 2nd ed. New York: Springer-Verlag; 2003. p. 1–9.
26.
go back to reference Crawley MT, Savage P, Oakley F. Patient and operator dose during fluoroscopic examination of swallow mechanism. Br J Radiol. 2004;77:654–6.PubMedCrossRef Crawley MT, Savage P, Oakley F. Patient and operator dose during fluoroscopic examination of swallow mechanism. Br J Radiol. 2004;77:654–6.PubMedCrossRef
27.
go back to reference Zammit-Maempel I, Chapple CL, Leslie P. Radiation dose in videofluoroscopic swallow studies. Dysphagia. 2007;22:13–5.PubMedCrossRef Zammit-Maempel I, Chapple CL, Leslie P. Radiation dose in videofluoroscopic swallow studies. Dysphagia. 2007;22:13–5.PubMedCrossRef
Metadata
Title
Evaluation of Swallowing Using 320-Detector-Row Multislice CT. Part I: Single- and Multiphase Volume Scanning for Three-dimensional Morphological and Kinematic Analysis
Authors
Naoko Fujii
Yoko Inamoto
Eiichi Saitoh
Mikoto Baba
Sumiko Okada
Satoshi Yoshioka
Toshiaki Nakai
Yoshihiro Ida
Kazuhiro Katada
Jeffrey B. Palmer
Publication date
01-06-2011
Publisher
Springer-Verlag
Published in
Dysphagia / Issue 2/2011
Print ISSN: 0179-051X
Electronic ISSN: 1432-0460
DOI
https://doi.org/10.1007/s00455-009-9268-2

Other articles of this Issue 2/2011

Dysphagia 2/2011 Go to the issue