Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 6/2013

01-06-2013 | Cornea

Evaluation of rigid gas permeable lens fitting in keratoconic patients with optical coherence tomography

Authors: Amal M. Elbendary, Waleed Abou Samra

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 6/2013

Login to get access

Abstract

Purpose

To assess fitting of rigid gas permeable (RGP) lenses in patients with keratoconus, using spectral domain optical coherence tomography (SD-OCT).

Methods

The study was conducted on 30 eyes of 30 keratoconic patients fitted with RGP lenses, namely Rose K2 lens. Biomicroscopic examination with and without RGP lens was done. Fluorescein pattern was examined to determine the fitting, if ideal (three-point light touch), steep (central fluorescein pooling) or flat (central heavy bearing touch). Post-lens tear film thickness was measured centrally and at the lens edges using SD-OCT. Patient’s comfort was assessed and graded.

Results

Mean central post-lens tear film thickness was 35.1 ± 7.3 μ in patients with ideal fitting. Mean post-lens tear film thickness of 50.4 ± 8.2 μ and 25.3 ± 6.1 μ was noted in patients with steep and flat fitting, respectively. Mean post-lens tear film thickness of 102.5 ± 12.1 μ, 85.4 ± 11.4 μ, 135.6 ± 13.3 μ was demonstrated in eyes with ideal, steep and flat edge lift, respectively. Tear film thickness under the edges was significantly (p = 0.04) lower in patients unsatisfied with their contact lenses.

Conclusion

SD-OCT can image and measure the tear film thickness in keratoconic patients with different fitting patterns of RGP lenses. OCT- guided fitting can be used to evaluate and modify the lens parameters to increase patient satisfaction. Lens intolerance may be related to edge lift rather than central fitting.
Literature
1.
go back to reference Edrington TB, Szczotka LB, Barr JT, Achtenberg JF, Burger DS, Janoff AM, Olafsson HE, Chun MW, Boyle JW, Gordon MO, Zadnik K (1999) Rigid contact lens fitting relationships in keratoconus. Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group. Optom Vis Sci 76:692–699PubMedCrossRef Edrington TB, Szczotka LB, Barr JT, Achtenberg JF, Burger DS, Janoff AM, Olafsson HE, Chun MW, Boyle JW, Gordon MO, Zadnik K (1999) Rigid contact lens fitting relationships in keratoconus. Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group. Optom Vis Sci 76:692–699PubMedCrossRef
2.
go back to reference Ozkurt YB, Sengor T, Kurna S, Evciman T, Acikgoz S, Haboğlu M, Aki S (2008) Rose K contact lens fitting for keratoconus. Int Ophthalmol 28:395–398PubMedCrossRef Ozkurt YB, Sengor T, Kurna S, Evciman T, Acikgoz S, Haboğlu M, Aki S (2008) Rose K contact lens fitting for keratoconus. Int Ophthalmol 28:395–398PubMedCrossRef
3.
go back to reference Little SA, Bruce AS (1995) Osmotic determinants of post-lens tear film morphology and hydrogel lens movement. Ophthalmic Physiol Opt 15:117–124PubMedCrossRef Little SA, Bruce AS (1995) Osmotic determinants of post-lens tear film morphology and hydrogel lens movement. Ophthalmic Physiol Opt 15:117–124PubMedCrossRef
4.
go back to reference Josephson JE, Caffery BE (1989) Proposed hypothesis for corneal infiltrates, microabrasions and red eye associated with extended wear. Optom Vis Sci 66:192PubMedCrossRef Josephson JE, Caffery BE (1989) Proposed hypothesis for corneal infiltrates, microabrasions and red eye associated with extended wear. Optom Vis Sci 66:192PubMedCrossRef
5.
go back to reference Wang J, Jiao S, Ruggeri M, Abou Shousha M, Chen Q (2009) In situ visualization of tears on contact Lens using ultra high resolution optical coherence tomography. Eye Contact Lens 2:44–49CrossRef Wang J, Jiao S, Ruggeri M, Abou Shousha M, Chen Q (2009) In situ visualization of tears on contact Lens using ultra high resolution optical coherence tomography. Eye Contact Lens 2:44–49CrossRef
6.
go back to reference Fukuda S, Kawana K, Yasuno Y, Oshika T (2010) Repeatability and reproducibility of anterior ocular biometric measurements with 2-dimensional and 3-dimensional optical coherence tomography. J Cataract Refract Surg 36:1867–1873PubMedCrossRef Fukuda S, Kawana K, Yasuno Y, Oshika T (2010) Repeatability and reproducibility of anterior ocular biometric measurements with 2-dimensional and 3-dimensional optical coherence tomography. J Cataract Refract Surg 36:1867–1873PubMedCrossRef
7.
go back to reference Huang JY, Pekmezci M, Yaplee S, Lin S (2010) Intra-examiner repeatability and agreement of corneal pachymetry map measurement by time-domain and Fourier-domain optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 248:1647–1656PubMedCrossRef Huang JY, Pekmezci M, Yaplee S, Lin S (2010) Intra-examiner repeatability and agreement of corneal pachymetry map measurement by time-domain and Fourier-domain optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 248:1647–1656PubMedCrossRef
8.
go back to reference Chen Q, Wang J, Tao A, Shen M, Jiao S, Lu F (2010) Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses. Investig Ophthalmol Vis Sci 51:1988–1993CrossRef Chen Q, Wang J, Tao A, Shen M, Jiao S, Lu F (2010) Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses. Investig Ophthalmol Vis Sci 51:1988–1993CrossRef
9.
go back to reference Rose P (1997) Comments in Rose k keratoconus lens- Keratoconus and post graft lenses. In: NOVA contact lenses fitting guide. p. 7–11 Rose P (1997) Comments in Rose k keratoconus lens- Keratoconus and post graft lenses. In: NOVA contact lenses fitting guide. p. 7–11
10.
go back to reference Szczotka LB, Rabinowitz YS, Yang H (1996) Influence of contact lens wear on the corneal topography of keratoconus. CLAO J 22:270–273PubMed Szczotka LB, Rabinowitz YS, Yang H (1996) Influence of contact lens wear on the corneal topography of keratoconus. CLAO J 22:270–273PubMed
11.
go back to reference Jinabhai A, O’Donell C, Radhakrishnan H (2012) Changes in refraction, ocular aberrrations, and corneal structure after suspending rigid gas-permeable contact lens wear in keratoconus. Cornea 31:500–508PubMedCrossRef Jinabhai A, O’Donell C, Radhakrishnan H (2012) Changes in refraction, ocular aberrrations, and corneal structure after suspending rigid gas-permeable contact lens wear in keratoconus. Cornea 31:500–508PubMedCrossRef
12.
go back to reference Northey LC, Gifford P, Boneham GC (2012) Comparison of Topcon optical coherence tomography and ultrasound pachymetry. Optom Vis Sci 89:1708–1714PubMedCrossRef Northey LC, Gifford P, Boneham GC (2012) Comparison of Topcon optical coherence tomography and ultrasound pachymetry. Optom Vis Sci 89:1708–1714PubMedCrossRef
13.
14.
go back to reference Fernandez-Velazquez FJ (2012) Kerasoft IC compared to Rose-K in the management of corneal ectasias. Contact Lens Anterior Eye 35:175–179PubMedCrossRef Fernandez-Velazquez FJ (2012) Kerasoft IC compared to Rose-K in the management of corneal ectasias. Contact Lens Anterior Eye 35:175–179PubMedCrossRef
15.
go back to reference Doughty MJ, Fonn D, Richter D, Simpson T, Caffery B, Gordon K (1997) A patient questionnaire approach to estimating the prevalence of dry eye symptoms in patients presenting to optometric practices across Canada. Optom Vis Sci 74:624–631PubMedCrossRef Doughty MJ, Fonn D, Richter D, Simpson T, Caffery B, Gordon K (1997) A patient questionnaire approach to estimating the prevalence of dry eye symptoms in patients presenting to optometric practices across Canada. Optom Vis Sci 74:624–631PubMedCrossRef
16.
go back to reference Wang J, Fonn D, Simpson TL, Jones L (2002) The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography. Am J Ophthalmol 133:315–319PubMedCrossRef Wang J, Fonn D, Simpson TL, Jones L (2002) The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography. Am J Ophthalmol 133:315–319PubMedCrossRef
17.
go back to reference Radhakrishnan S, Rollins AM, Roth JE, Yazdanfar S, Westphal V, Bardenstein DS, Izatt JA (2001) Real-time optical coherence tomography of the anterior segment at 1310 nm. Arch Ophthalmol 119:1179–1185PubMed Radhakrishnan S, Rollins AM, Roth JE, Yazdanfar S, Westphal V, Bardenstein DS, Izatt JA (2001) Real-time optical coherence tomography of the anterior segment at 1310 nm. Arch Ophthalmol 119:1179–1185PubMed
18.
go back to reference Feng Y, Varikooty J, Simpson TL (2001) Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography. Cornea 20:480–483PubMedCrossRef Feng Y, Varikooty J, Simpson TL (2001) Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography. Cornea 20:480–483PubMedCrossRef
19.
go back to reference Wang J, Fonn D, Simpson TL (2003) Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure. Investig Ophthalmol Vis Sci 44:1070–1074CrossRef Wang J, Fonn D, Simpson TL (2003) Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure. Investig Ophthalmol Vis Sci 44:1070–1074CrossRef
20.
go back to reference Shen M, Cui L, Riley C, Wang MR, Wang J (2011) Characterization of soft contact lens edge fitting using ultra-high resolution and ultra-long scan depth optical coherence tomography. Investig Ophthalmol Vis Sci 52:4091–4097CrossRef Shen M, Cui L, Riley C, Wang MR, Wang J (2011) Characterization of soft contact lens edge fitting using ultra-high resolution and ultra-long scan depth optical coherence tomography. Investig Ophthalmol Vis Sci 52:4091–4097CrossRef
21.
go back to reference Lin MC, Chen YQ, Polse KA (2003) The effects of ocular and lens parameters on the post-lens tear thickness. Eye Contact Lens 29:S33–S36, discussion S57–59, S192–194PubMedCrossRef Lin MC, Chen YQ, Polse KA (2003) The effects of ocular and lens parameters on the post-lens tear thickness. Eye Contact Lens 29:S33–S36, discussion S57–59, S192–194PubMedCrossRef
22.
go back to reference Prydal JI, Campbell FW (1992) Study of precorneal tear film thickness and structure by interferometry and confocal microscopy. Investig Ophthalmol Vis Sci 33:1996–2005 Prydal JI, Campbell FW (1992) Study of precorneal tear film thickness and structure by interferometry and confocal microscopy. Investig Ophthalmol Vis Sci 33:1996–2005
23.
go back to reference Nichols JJ, King-Smith PE (2003) Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry. Investig Ophthalmol Vis Sci 44:68–77CrossRef Nichols JJ, King-Smith PE (2003) Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry. Investig Ophthalmol Vis Sci 44:68–77CrossRef
24.
go back to reference Prydal JI, Artal P, Woon H, Campbell FW (1992) Study of human precorneal tear film thickness and structure using laser interferometry. Investig Ophthalmol Vis Sci 33:2006–2011 Prydal JI, Artal P, Woon H, Campbell FW (1992) Study of human precorneal tear film thickness and structure using laser interferometry. Investig Ophthalmol Vis Sci 33:2006–2011
25.
go back to reference Wang J, Fonn D, Simpson TL, Jones L (2003) Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography. Investig Ophthalmol Vis Sci 44:2524–2528CrossRef Wang J, Fonn D, Simpson TL, Jones L (2003) Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography. Investig Ophthalmol Vis Sci 44:2524–2528CrossRef
26.
go back to reference Millis EAW (2005) Contact lens complications in medical contact lens practice. Elsevier, Butterworth Heinemann, China, p 50 Millis EAW (2005) Contact lens complications in medical contact lens practice. Elsevier, Butterworth Heinemann, China, p 50
27.
go back to reference Edrington TB, Gundel RE, Libassi DP, Wagner H, Pierce GE, Walline JJ, Barr JT, Olafsson HE, Steger-May K, Achtenberg J, Wilson BS, Gordon MO, Zadnik K, CLEK STUDY GROUP (2004) Variables affecting rigid contact lens comfort in the collaborative longitudinal evaluation of keratoconus (CLEK) study. Optom Vis Sci 81:182–188PubMedCrossRef Edrington TB, Gundel RE, Libassi DP, Wagner H, Pierce GE, Walline JJ, Barr JT, Olafsson HE, Steger-May K, Achtenberg J, Wilson BS, Gordon MO, Zadnik K, CLEK STUDY GROUP (2004) Variables affecting rigid contact lens comfort in the collaborative longitudinal evaluation of keratoconus (CLEK) study. Optom Vis Sci 81:182–188PubMedCrossRef
Metadata
Title
Evaluation of rigid gas permeable lens fitting in keratoconic patients with optical coherence tomography
Authors
Amal M. Elbendary
Waleed Abou Samra
Publication date
01-06-2013
Publisher
Springer-Verlag
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 6/2013
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-013-2271-1

Other articles of this Issue 6/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 6/2013 Go to the issue