Skip to main content
Top
Published in: European Spine Journal 7/2019

01-07-2019 | Original Article

Evaluation of iliac screw, S2 alar-iliac screw and laterally placed triangular titanium implants for sacropelvic fixation in combination with posterior lumbar instrumentation: a finite element study

Authors: Gloria Casaroli, Fabio Galbusera, Ruchi Chande, Derek Lindsey, Ali Mesiwala, Scott Yerby, Marco Brayda-Bruno

Published in: European Spine Journal | Issue 7/2019

Login to get access

Abstract

Purpose

This study aimed to implement laterally placed triangular titanium implants as a technique of sacropelvic fixation in long posterior lumbar instrumentation and to characterize the effects of iliac screws, S2 alar-iliac screws and of triangular implants on rod and S1 pedicle screw stresses.

Methods

Four female models of the lumbopelvic spine were created. For each of them, five finite element models replicating the following configurations were generated: intact, posterior fixation with pedicle screws to S1 (PED), with PED and iliac screws (IL), with PED and S2 alar-iliac (S2AI) screws, and with PED and bilateral triangular titanium implants (SI). Simulations were conducted in compression, flexion–extension, lateral bending and axial rotation. Rod stresses in the L5-S1 segment as well as in the S1 pedicle screws were compared.

Results

One anatomical model was not simulated due to dysmorphia of the sacroiliac joints. PED resulted in the highest implant stresses. Values up to 337 MPa in lateral bending were noted, which were more than double than the other configurations. When compared with IL, S2AI and SI resulted in lower stresses in both screws and rods (on average 33% and 41% for S2AI and 17% and 50% for SI).

Conclusions

Implant stresses after S2AI and SI fixations were lower than those attributable to IL. Therefore, pedicle screws and rods may have a lower risk of mechanical failure when coupled with sacropelvic fixation via S2AI or triangular titanium implants, although the risk of clinical loosening remains an area of further investigation.

Graphical abstract

These slides can be retrieved under Electronic Supplementary Material.
Appendix
Available only for authorised users
Literature
16.
go back to reference Heiney J, Capobianco R, Cher D (2015) A systematic review of minimally invasive sacroiliac joint fusion utilizing a lateral transarticular technique. Int J Spine Surg 9:40CrossRefPubMedPubMedCentral Heiney J, Capobianco R, Cher D (2015) A systematic review of minimally invasive sacroiliac joint fusion utilizing a lateral transarticular technique. Int J Spine Surg 9:40CrossRefPubMedPubMedCentral
30.
37.
go back to reference Pihlajamaki H, Myllynen P, Bostman O (1997) Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg Br 79:183–189CrossRefPubMed Pihlajamaki H, Myllynen P, Bostman O (1997) Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg Br 79:183–189CrossRefPubMed
40.
go back to reference Camisa W, Condez BI, Leasure JM et al (2014) Development of a biomechanical model for sacroiliac range of motion. In: 2014 AAOS Annual Meeting, pp 42–43 Camisa W, Condez BI, Leasure JM et al (2014) Development of a biomechanical model for sacroiliac range of motion. In: 2014 AAOS Annual Meeting, pp 42–43
41.
go back to reference Ambati D, Wright E, Lehman R et al (2015) Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study. Spine J 15(8):1812–1822CrossRefPubMed Ambati D, Wright E, Lehman R et al (2015) Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study. Spine J 15(8):1812–1822CrossRefPubMed
42.
go back to reference Liu C, Kamara A, Yan Y (2018) Investigation into the biomechanics of lumbar spine micro-dynamic pedicle screw. BMC Musculoskelet Disord 19(231):1–11 Liu C, Kamara A, Yan Y (2018) Investigation into the biomechanics of lumbar spine micro-dynamic pedicle screw. BMC Musculoskelet Disord 19(231):1–11
Metadata
Title
Evaluation of iliac screw, S2 alar-iliac screw and laterally placed triangular titanium implants for sacropelvic fixation in combination with posterior lumbar instrumentation: a finite element study
Authors
Gloria Casaroli
Fabio Galbusera
Ruchi Chande
Derek Lindsey
Ali Mesiwala
Scott Yerby
Marco Brayda-Bruno
Publication date
01-07-2019
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 7/2019
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-019-06006-0

Other articles of this Issue 7/2019

European Spine Journal 7/2019 Go to the issue

Editorial

Editorial

Announcements

Announcement