Skip to main content
Top
Published in: European Radiology 6/2005

01-06-2005 | Cardiac

Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time

Authors: Shi-Zheng Zhang, Xiu-Hua Hu, Qiao-Wei Zhang, Wen-Xin Huang

Published in: European Radiology | Issue 6/2005

Login to get access

Abstract

The aim of our study is to evaluate computed tomography (CT) coronary angiography in patients with a high heart rate using 16-slice spiral CT with 0.37-s gantry rotation time. We compare the image quality of patients whose heart rates were over 70 beats per minute (bpm) with that of patients whose heart rates were 70 bpm or less. Sixty patients with various heart rates underwent retrospectively ECG-gated multislice spiral CT (MSCT) coronary angiography. Two experienced observers who were blind to the heart rates of the patients evaluated all the MSCT coronary angiographic images and calculated the assessable segments. A total of 620 out of 891 (69.6%) segments were satisfactorily visualized. On average, 10.3 coronary artery segments per patient could be evaluated. In 36 patients whose heart rates were below 70 bpm [mean 62.2 bpm±5.32 (standard deviation, SD)], the number of assessable segments was 10.72±2.02 (SD). In the other 24 patients whose heart rates were above 70 bpm [mean 78.6 bpm±8.24 (SD)], the corresponding number was 9.75±1.74 (SD). No statistically significant difference was found in these two subgroups’ t test, P>0.05. The new generation of 16-slice spiral CT with 0.37-s rotation time can satisfactorily evaluate the coronary arteries of patients with high heart rates (above 70 bpm, up to 102 bpm).
Literature
1.
go back to reference Schroeder S, Kopp AF, Kuettner A et al (2002) Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clin Imaging 26:106–111CrossRefPubMed Schroeder S, Kopp AF, Kuettner A et al (2002) Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clin Imaging 26:106–111CrossRefPubMed
2.
go back to reference Nieman K, Rensing BJ, van Geuns RJ et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMed Nieman K, Rensing BJ, van Geuns RJ et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMed
3.
go back to reference Giesler T, Baum U, Ropers D et al (2002) Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. Am J Roentgenol 179:911–916 Giesler T, Baum U, Ropers D et al (2002) Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. Am J Roentgenol 179:911–916
4.
go back to reference Pannu HK, Flohr TG, Corl FM et al (2003) Current concepts in multi-detector row CT evaluation of the coronary arteries: principle, techniques, and anatomy. RadioGraphics 23:s111–s125 Pannu HK, Flohr TG, Corl FM et al (2003) Current concepts in multi-detector row CT evaluation of the coronary arteries: principle, techniques, and anatomy. RadioGraphics 23:s111–s125
5.
go back to reference Nieman K, Cademartiri F, Lemos PA et al (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054 Nieman K, Cademartiri F, Lemos PA et al (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054
6.
go back to reference Kopp AF, Schroeder S, Kuettner A et al (2001) Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 221: 683–688PubMed Kopp AF, Schroeder S, Kuettner A et al (2001) Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 221: 683–688PubMed
7.
go back to reference Kopp AF, Schroeder S, Kuettner A et al (2002) Non Invasive coronary angiography with high resolution multidector-row computed tomography: results in 102 patients. Eur Heart J 23:1714–1725PubMed Kopp AF, Schroeder S, Kuettner A et al (2002) Non Invasive coronary angiography with high resolution multidector-row computed tomography: results in 102 patients. Eur Heart J 23:1714–1725PubMed
8.
go back to reference Hamoir XL, Flohr T, Hamoir V et al (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time. Eur Radiol 15(2):296–304 Hamoir XL, Flohr T, Hamoir V et al (2005) Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time. Eur Radiol 15(2):296–304
9.
go back to reference Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate-adapted image reconstruction in mutidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate-adapted image reconstruction in mutidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed
10.
go back to reference van Ooijen PM, Dorgelo J, Zijlstra F et al (2004) Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT. Eur Radiol 14:2163–2171 van Ooijen PM, Dorgelo J, Zijlstra F et al (2004) Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT. Eur Radiol 14:2163–2171
11.
go back to reference Shi H, Aschoff AJ, Brambs HJ et al (2004) Multislice CT imaging of anomalous coronary arteries. Eur Radiol 14:2172–2181 Shi H, Aschoff AJ, Brambs HJ et al (2004) Multislice CT imaging of anomalous coronary arteries. Eur Radiol 14:2172–2181
Metadata
Title
Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time
Authors
Shi-Zheng Zhang
Xiu-Hua Hu
Qiao-Wei Zhang
Wen-Xin Huang
Publication date
01-06-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 6/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2714-0

Other articles of this Issue 6/2005

European Radiology 6/2005 Go to the issue