Published in: International Journal of Legal Medicine 6/2021

01-11-2021 | Original Article

Estimation of the time since death based on body cooling: a comparative study of four temperature-based methods

Authors: Kenza Laplace, Eric Baccino, Pierre-Antoine Peyron

Published in: International Journal of Legal Medicine | Issue 6/2021

Login to get access

Abstract

The estimation of the time since death is an important task in forensic medicine that mainly relies on body cooling in the early post-mortem period. The rectum has been traditionally used to determine the central core temperature after death, though the external auditory canal has been proposed as an alternative site by several authors. The objective of this study was to assess the ability of four body temperature-based methods (Henssge’s rectal nomogram, Henssge’s brain nomogram, and Baccino’s both interval and global formulae based on ear temperature) to estimate the post-mortem interval (PMI). PMI calculations were carried out based on ear and rectal temperature measurements performed with a reference metal probe on 100 inpatient bodies with an average PMI of 4.5 ± 2.5 h. For practical purposes, ear temperature measurements were applied to Henssge’s brain nomogram. All methods could be applied to 81 cases, since high body temperatures prevented the rectal nomogram method from being used in most of the remaining cases. The actual PMI was within the time interval (95% CI) provided by the rectal nomogram method in 72.8% of cases, and in 63.0% to 76.5% of cases when using ear temperature-based methods. The proportions of adequate estimates did not differ statistically between the different methods. When the methods failed to provide a reliable time interval, all except the brain nomogram tended to underestimate the PMI. Similar results were obtained in the subgroup of normothermic patients at the time of death (n = 63), confirming that the PMI calculations had not been biased by the inclusion of patients with thermoregulation disorders. Our findings are in accordance with the published literature which suggests that ear temperature-based methods are as reliable as those based on rectal temperature for estimating the early PMI and that they may be used as quick, simple, and non-invasive methods at the scene, although caution should be taken in interpreting their results given their high error rates. However, further research including field studies is recommended to confirm their practical relevance in forensic casework.
Literature
2.
go back to reference Henssge C (1988) Death time estimation in case work. I. The rectal temperature time of death nomogram. Forensic Sci Int 38:209–236CrossRef Henssge C (1988) Death time estimation in case work. I. The rectal temperature time of death nomogram. Forensic Sci Int 38:209–236CrossRef
3.
go back to reference Henssge C, Althaus L, Bolt J et al (2000) Experiences with a compound method for estimating the time since death. I. Rectal temperature nomogram for time since death. Int J Legal Med 113:303–319CrossRef Henssge C, Althaus L, Bolt J et al (2000) Experiences with a compound method for estimating the time since death. I. Rectal temperature nomogram for time since death. Int J Legal Med 113:303–319CrossRef
4.
go back to reference Henssge C, Beckmann ER, Wischhusen F, Brinkmann B (1984) Determination of the time of death by measurement of central brain temperature. Z Rechtsmed 93:1–22PubMed Henssge C, Beckmann ER, Wischhusen F, Brinkmann B (1984) Determination of the time of death by measurement of central brain temperature. Z Rechtsmed 93:1–22PubMed
6.
go back to reference Benzinger T, Taylor G (1963) Cranial measurements of internal temperature in man. In: Herzfeld CM (ed) Temperature Its Measurement and Control in Science and Industry. Volume 3, Part 3: Biology and Medicine. Reinhold Publishing Corporation, New York Benzinger T, Taylor G (1963) Cranial measurements of internal temperature in man. In: Herzfeld CM (ed) Temperature Its Measurement and Control in Science and Industry. Volume 3, Part 3: Biology and Medicine. Reinhold Publishing Corporation, New York
10.
go back to reference Rutty G, Smith N, Rutty J (1996) The use of infrared ear thermometry for determination of time since death in the early post mortem period. J Pathol 179(Suppl):13A Rutty G, Smith N, Rutty J (1996) The use of infrared ear thermometry for determination of time since death in the early post mortem period. J Pathol 179(Suppl):13A
11.
go back to reference Baccino E (1997) Response to Dr. Rutty’s letter re: ‘Outer ear temperature and time of death. Forensic Sci Int 87:173CrossRef Baccino E (1997) Response to Dr. Rutty’s letter re: ‘Outer ear temperature and time of death. Forensic Sci Int 87:173CrossRef
12.
go back to reference Wunderlich C, Seguin E (1871) Medical thermometry, and human temperature. William Wood & Company, New York Wunderlich C, Seguin E (1871) Medical thermometry, and human temperature. William Wood & Company, New York
13.
go back to reference Mackowiak PA (1997) History of clinical thermometry. In: Fever: basic mechanisms and management. Lippincott-Raven Publishers, Philadelphia Mackowiak PA (1997) History of clinical thermometry. In: Fever: basic mechanisms and management. Lippincott-Raven Publishers, Philadelphia
15.
go back to reference Myers MJ, Henderson M (1996) Assessment of two devices for measuring tympanic membrane temperature in swine, dairy cattle, and dairy calves. J Am Vet Med Assoc 208:1700–1701PubMed Myers MJ, Henderson M (1996) Assessment of two devices for measuring tympanic membrane temperature in swine, dairy cattle, and dairy calves. J Am Vet Med Assoc 208:1700–1701PubMed
18.
go back to reference Rutty GN (2015) The use of temperatures recorded from the external auditory canal for the estimation of the post-mortem interval. In: Madea B (ed) Estimation of the time since death, 3rd edn. CRC Press, London, pp 134–151 Rutty GN (2015) The use of temperatures recorded from the external auditory canal for the estimation of the post-mortem interval. In: Madea B (ed) Estimation of the time since death, 3rd edn. CRC Press, London, pp 134–151
19.
go back to reference Rutty GN (2001) The use of temperatures recorded from the external auditory canal in the estimation of the time since death. Medical Doctorate Thesis, University of Sheffield, England Rutty GN (2001) The use of temperatures recorded from the external auditory canal in the estimation of the time since death. Medical Doctorate Thesis, University of Sheffield, England
20.
go back to reference Rutty GN (2005) The estimation of the time since death using temperatures recorded from the external auditory canal : Part II: Using single temperatures from this site to estimate the time since death with consideration of environmental or body “factors” that could affect the estimation. Forensic Sci Med Pathol 1:113–123. https://doi.org/10.1385/FSMP:1:2:113CrossRefPubMed Rutty GN (2005) The estimation of the time since death using temperatures recorded from the external auditory canal : Part II: Using single temperatures from this site to estimate the time since death with consideration of environmental or body “factors” that could affect the estimation. Forensic Sci Med Pathol 1:113–123. https://​doi.​org/​10.​1385/​FSMP:​1:​2:​113CrossRefPubMed
23.
go back to reference Rutty GN (1997) Concerning the paper by Baccino et al., entitled: “Outer ear temperature and time of death” (Forensic Sci. Int., 83 (1996) 133–146). Forensic Sci Int 87:171–173CrossRef Rutty GN (1997) Concerning the paper by Baccino et al., entitled: “Outer ear temperature and time of death” (Forensic Sci. Int., 83 (1996) 133–146). Forensic Sci Int 87:171–173CrossRef
25.
go back to reference Meusy A, Peyron P-A, Molinari N et al (2017) Étude préliminaire de l’exactitude et du biais systématique de deux thermomètres infrarouges pour l’estimation du délai post-mortem précoce : peut-on utiliser les thermomètres infrarouges commercialisés pour déterminer l’heure du décès ? Rev Médecine Légale 8:97–104. https://doi.org/10.1016/j.medleg.2017.04.002CrossRef Meusy A, Peyron P-A, Molinari N et al (2017) Étude préliminaire de l’exactitude et du biais systématique de deux thermomètres infrarouges pour l’estimation du délai post-mortem précoce : peut-on utiliser les thermomètres infrarouges commercialisés pour déterminer l’heure du décès ? Rev Médecine Légale 8:97–104. https://​doi.​org/​10.​1016/​j.​medleg.​2017.​04.​002CrossRef
Metadata
Title
Estimation of the time since death based on body cooling: a comparative study of four temperature-based methods
Authors
Kenza Laplace
Eric Baccino
Pierre-Antoine Peyron
Publication date
01-11-2021
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Legal Medicine / Issue 6/2021
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-021-02635-7

Other articles of this Issue 6/2021

International Journal of Legal Medicine 6/2021 Go to the issue