Skip to main content
Top

01-08-2010 | TECHNICAL NOTE

Essentials of photometry for clinical electrophysiology of vision

Authors: Daphne L. McCulloch, Ruth Hamilton

Published in: Documenta Ophthalmologica | Issue 1/2010

Login to get access

Abstract

Electrophysiological testing of the visual system requires familiarity with photometry. This technical note outlines the concepts of photometry with a focus on information relevant to clinical ERG and VEP testing. Topics include photometric quantities, consideration of pupil size, specification of brief extended flash stimuli, and the influence of the spectral composition of visual stimuli. Standard units and terms are explained in the context of the ISCEV standards and guidelines for clinical electrophysiology of vision.
Footnotes
1
The full quote in context: “Boswell. ‘Then, Sir, what is poetry?’ Johnson. ‘Why, Sir, it is much easier to say what it is not. We all know what light is; but it is not easy to tell what it is.’” 12 April 1776, James Boswell, Life of Johnson (1791).
 
Literature
1.
go back to reference Bouguer P (1760) Traité d’Optique sur la Gradation de la Lumière. Académie des Sciences, Paris Bouguer P (1760) Traité d’Optique sur la Gradation de la Lumière. Académie des Sciences, Paris
2.
go back to reference Lambert JH (1760) Photometria sive de mensura et gradibus luminis, colorum et umbrae. Eberhard Klett, Augsburg Lambert JH (1760) Photometria sive de mensura et gradibus luminis, colorum et umbrae. Eberhard Klett, Augsburg
3.
go back to reference Saidman J (1933) Sur la visibilité de l’ultraviolet jusqu’à la longuer de l’onde 3130 A [313 nm]. C R Hebd Séances Acad Sci 196:1537–1539 Saidman J (1933) Sur la visibilité de l’ultraviolet jusqu’à la longuer de l’onde 3130 A [313 nm]. C R Hebd Séances Acad Sci 196:1537–1539
4.
go back to reference Gaydon AG (1938) Colour sensations produced by ultraviolet light. J Phys Soc (London) 50:714–720CrossRef Gaydon AG (1938) Colour sensations produced by ultraviolet light. J Phys Soc (London) 50:714–720CrossRef
5.
go back to reference Calibration Standard Committee of ISCEV: Brigell M (chair), Bach M, Barber C, Moskowitz A, Robson JG (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193 Calibration Standard Committee of ISCEV: Brigell M (chair), Bach M, Barber C, Moskowitz A, Robson JG (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193
6.
go back to reference Wyszecki G, Stiles WS (2000) Color science, 2nd edn. Wiley, New York Wyszecki G, Stiles WS (2000) Color science, 2nd edn. Wiley, New York
7.
go back to reference Ohno Y (2006) Handbook of optoelectronics. Taylor and Francis, New York Ohno Y (2006) Handbook of optoelectronics. Taylor and Francis, New York
8.
go back to reference Ohta N, Robertson AR (2005) Colorimetry: fundamentals and applications. Wiley, New YorkCrossRef Ohta N, Robertson AR (2005) Colorimetry: fundamentals and applications. Wiley, New YorkCrossRef
9.
go back to reference Commission Internationale de l’Eclairage (1990) CIE 1988 2° Spectral luminous efficiency function for photopic vision, No. 86. CIE, Vienna Commission Internationale de l’Eclairage (1990) CIE 1988 2° Spectral luminous efficiency function for photopic vision, No. 86. CIE, Vienna
10.
go back to reference Commission Internationale d’Eclairage (2005) CIE 10 degree photopic photometric observer, No. 165. CIE, Vienna Commission Internationale d’Eclairage (2005) CIE 10 degree photopic photometric observer, No. 165. CIE, Vienna
11.
go back to reference Commission Internationale d’Eclairage (1951) CIE Proceedings 1951. Bureau Central de la CIE, New York Commission Internationale d’Eclairage (1951) CIE Proceedings 1951. Bureau Central de la CIE, New York
12.
go back to reference Kawasaki K, Tanabe J, Wakabayashi K, Shirao Y (2006). In: Heckenlively JR, Arden GB (eds) Principles and practice of clinical electrophysiology of vision, 2nd edn. MIT Press, Cambridge, pp 585–591 Kawasaki K, Tanabe J, Wakabayashi K, Shirao Y (2006). In: Heckenlively JR, Arden GB (eds) Principles and practice of clinical electrophysiology of vision, 2nd edn. MIT Press, Cambridge, pp 585–591
13.
go back to reference Bureau Internationale des Poids et Mesures (1979) Comptes Rendus des Séances de la 16e Conférence Générale des Poids et Mesures. Résolution 3. Pavilion de Breteuil, F-92310 Sèvres, France Bureau Internationale des Poids et Mesures (1979) Comptes Rendus des Séances de la 16e Conférence Générale des Poids et Mesures. Résolution 3. Pavilion de Breteuil, F-92310 Sèvres, France
14.
go back to reference Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP, Vaegan (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 120:111–119 Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP, Vaegan (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 120:111–119
15.
go back to reference Brown M, Marmor MF, Vaegan, Zrenner E, Brigell MG, Bach M (2004) ISCEV standard for clinical electro-oculography (EOG). Doc Ophthalmol 113:205–212 Brown M, Marmor MF, Vaegan, Zrenner E, Brigell MG, Bach M (2004) ISCEV standard for clinical electro-oculography (EOG). Doc Ophthalmol 113:205–212
16.
go back to reference Holder GE, Brigell MG, Hawlina M, Meigen T, Bach M (2007) ISCEV Standard for clinical pattern electroretinography (2007 update). Doc Ophthalmol 114:111–116CrossRefPubMed Holder GE, Brigell MG, Hawlina M, Meigen T, Bach M (2007) ISCEV Standard for clinical pattern electroretinography (2007 update). Doc Ophthalmol 114:111–116CrossRefPubMed
17.
go back to reference Hood DC, Bach M, Brigell MG, Keating D, Kondo M, Lyons JS et al. (2007) ISCEV Guidelines for clinical multifocal electroretinography (2007 edition). Doc Ophthalmol 2007 Hood DC, Bach M, Brigell MG, Keating D, Kondo M, Lyons JS et al. (2007) ISCEV Guidelines for clinical multifocal electroretinography (2007 edition). Doc Ophthalmol 2007
18.
go back to reference Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell MG, Bach M (2009) Standard for clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell MG, Bach M (2009) Standard for clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed
19.
go back to reference Pugh EN (1988) Perception and motivation. In: Atkinson RC, Herrnstein RJ, Lindzey G, Luce RD (eds) Stevens’ handbook of experimental psychology, vol 1, 2nd edn. Wiley, New York, pp 75–163 Pugh EN (1988) Perception and motivation. In: Atkinson RC, Herrnstein RJ, Lindzey G, Luce RD (eds) Stevens’ handbook of experimental psychology, vol 1, 2nd edn. Wiley, New York, pp 75–163
20.
go back to reference Gullstrand A (1909). In: von Helmholtz H (ed) Physiological optics. Voss, Hamburg, pp 350–358 Gullstrand A (1909). In: von Helmholtz H (ed) Physiological optics. Voss, Hamburg, pp 350–358
21.
go back to reference Mactier H, Maroo S, Bradnam MS, Hamilton R (2008) Ocular biometry in preterm infants: implications for estimation of retinal illuminance. Invest Ophthalmol Vis Sci 49:453–457CrossRefPubMed Mactier H, Maroo S, Bradnam MS, Hamilton R (2008) Ocular biometry in preterm infants: implications for estimation of retinal illuminance. Invest Ophthalmol Vis Sci 49:453–457CrossRefPubMed
22.
go back to reference Hansen RM, Fulton AB (1989) Psychophysical estimates of ocular media density of human infants. Vis Res 29:687–690CrossRefPubMed Hansen RM, Fulton AB (1989) Psychophysical estimates of ocular media density of human infants. Vis Res 29:687–690CrossRefPubMed
23.
go back to reference van de Kraats J, van Norren D (2007) Optical density of the aging human ocular media in the visible and the UV. J Opt Soc America A 24:1842–1857CrossRef van de Kraats J, van Norren D (2007) Optical density of the aging human ocular media in the visible and the UV. J Opt Soc America A 24:1842–1857CrossRef
24.
go back to reference Troland LT (1917) On the measurement of visual stimulation intensities. J Exp Psych 2:1–33CrossRef Troland LT (1917) On the measurement of visual stimulation intensities. J Exp Psych 2:1–33CrossRef
25.
go back to reference Makous W (1999). In: Carpenter RHS, Robson JG (eds) Vision research: a practical guide to laboratory methods. Oxford University Press, Oxford, pp 1–49 Makous W (1999). In: Carpenter RHS, Robson JG (eds) Vision research: a practical guide to laboratory methods. Oxford University Press, Oxford, pp 1–49
26.
go back to reference Robson JG (1999). In: Carpenter RHS, Robson JG (eds) Vision research: a practical guide to laboratory methods. Oxford University Press, Oxford, pp 50-80 Robson JG (1999). In: Carpenter RHS, Robson JG (eds) Vision research: a practical guide to laboratory methods. Oxford University Press, Oxford, pp 50-80
27.
go back to reference Castelletto S, Rastello ML (1998) Luminous and photon standards by trap detectors. IEEE Trans Instrum Meas 47:900–906CrossRef Castelletto S, Rastello ML (1998) Luminous and photon standards by trap detectors. IEEE Trans Instrum Meas 47:900–906CrossRef
28.
go back to reference Stiles WS, Crawford BH (1933) The luminous efficiency of rays entering the eye pupil at different points. Proc R Soc Lond B 112:428–450CrossRef Stiles WS, Crawford BH (1933) The luminous efficiency of rays entering the eye pupil at different points. Proc R Soc Lond B 112:428–450CrossRef
29.
30.
go back to reference Gonzalez P, Parks S, Dolan F, Keating D (2004) The effects of pupil size on the multifocal electroretinogram. Doc Ophthalmol 109:67–72CrossRefPubMed Gonzalez P, Parks S, Dolan F, Keating D (2004) The effects of pupil size on the multifocal electroretinogram. Doc Ophthalmol 109:67–72CrossRefPubMed
31.
go back to reference Poloschek CM, Bach M (2009) Can we do without mydriasis in multifocal ERG recordings? Doc Ophthalmol 118:121–128CrossRefPubMed Poloschek CM, Bach M (2009) Can we do without mydriasis in multifocal ERG recordings? Doc Ophthalmol 118:121–128CrossRefPubMed
32.
go back to reference Alpern M, Ching CC, Kitahara K (1983) Directional sensitivity of the retinal rods. J Physiol 343:577–592PubMed Alpern M, Ching CC, Kitahara K (1983) Directional sensitivity of the retinal rods. J Physiol 343:577–592PubMed
33.
Metadata
Title
Essentials of photometry for clinical electrophysiology of vision
Authors
Daphne L. McCulloch
Ruth Hamilton
Publication date
01-08-2010
Publisher
Springer-Verlag
Published in
Documenta Ophthalmologica / Issue 1/2010
Print ISSN: 0012-4486
Electronic ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-010-9233-2