Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2015

Open Access 01-12-2015 | Erratum

Erratum to: Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty

Authors: Shih-Jie Lin, Chien-Ying Lee, Kuo-Chin Huang, Kuo-Ti Peng, Tsan-Wen Huang, Mel S. Lee, Robert Wen-Wei Hsu, Wun-Jer Shen

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2015

Login to get access

Excerpt

After publication of the original article [1] it came to our attention that there were errors in Table 3. The data in the first parameter [preoperative coronal MA(°)] was incorrect and has been corrected in Table 3 below.
Table 3
Radiographic data of patients with genu varum
 
Group A
Group B
 
 
n = 39
n = 51
 
Parameters
Mean ± SD (min-max)
Mean ± SD (min-max)
p-value
Preoperative coronal MA (°)
159.7 ± 3.9 (150–165)
158.3 ± 4.2 (143–165)
0.443
Postoperative coronal MA (°)
179.5 ± 1.7 (178–184)
177.9 ± 2.4 (176–181)
0.572
Frontal femoral angle (°)
90.6 ± 1.7 (86–91)
89.7 ± 1.5 (84–91)
0.414
Sagittal femoral angle (°)
1.6 ± 1.2 (0–6)
3.5 ± 2.8 (1–7)
<0.001*
Femoral rotation angle (°)
1.0 ± 0.7 (0–3)
1.7 ± 1.1 (0–6)
0.127
Frontal tibial angle (°)
90.0 ± 0.5 (89–91)
89.9 ± 1.4 (88–91)
0.714
Sagittal tibial angle (°)
87.9 ± 1.8 (84–90)
87.7 ± 2.2 (80–91)
0.518
Group A: osteoarthritis with genu varum and underwent computer-assisted surgery total knee arthroplasty (CAS-TKA)
Group B: osteoarthritis with genu varum and underwent conventional TKA
p values for between-group comparison were determined by Mann–Whitney U test
*Statistically significant (p < 0.05)
Literature
1.
go back to reference Lin S, Lee C, Huang K, Peng K, Huang T, Lee MS, et al. Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty. J Orthop Surg Res. 2015;10:135.PubMedCentralCrossRefPubMed Lin S, Lee C, Huang K, Peng K, Huang T, Lee MS, et al. Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty. J Orthop Surg Res. 2015;10:135.PubMedCentralCrossRefPubMed
Metadata
Title
Erratum to: Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty
Authors
Shih-Jie Lin
Chien-Ying Lee
Kuo-Chin Huang
Kuo-Ti Peng
Tsan-Wen Huang
Mel S. Lee
Robert Wen-Wei Hsu
Wun-Jer Shen
Publication date
01-12-2015
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2015
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-015-0293-6

Other articles of this Issue 1/2015

Journal of Orthopaedic Surgery and Research 1/2015 Go to the issue