Skip to main content
Top
Published in: Surgical Endoscopy 7/2004

01-07-2004 | Original article

Ergonomic assessment of the static stress confronted by surgeons during laparoscopic cholecystectomy

Authors: A. Vereczkei, H. Feussner, T. Negele, F. Fritzsche, T. Seitz, H. Bubb, Ö. P. Horváth

Published in: Surgical Endoscopy | Issue 7/2004

Login to get access

Abstract

Background

Only a few reports on static strain in the spine, neck, and head of the surgeon are available, describing it as “distinctly harmful.” The aim of this study was to objectively prove the static burden during laparoscopic operations. For this, new industrial software called PCMAN was used, capable of measuring and comparing the postures of the surgeon at different monitor placements.

Methods

Two simultaneous and synchronized video recordings of laparoscopic cholecystectomies (LC) were done using miniDV digital camcorders with the cameras standing at a 90° angle to each other. Twenty operations were performed using two different placements of the monitor. In 10 cases, the monitor was placed at the patient’s head in the center, and in 10 cases at the left side of the patient. Using the time codes of the recordings, different steps of the operation were identified, and the duration of these measured in seconds. Very characteristic, longer lasting postures were imported to and analyzed with the software. Results of the different setups were compared to each other, and to an “ideal” comfort posture.

Results

During the intermediate steps of the operations the rate of static phases is significantly higher. Measuring the typical postures of these phases the trunk and head are significantly more rotated and bent than in comfort positions. When the monitor was at the side of the patient facing the surgeon, results were closer to the comfort posture.

Conclusions

It was proven that surgeons are confronted by significant static burden during LC. The software used was able to evaluate objectively the static posture of the surgeon during series of LC. Results also confirmed that the position of monitors significantly influences the surgeon’s posture. Best setups for the whole team can be achieved by adjustable multiple monitor systems.
Literature
1.
go back to reference Berguer, R, Rab, GT, Abu-Ghaida, H, Alarcon, A, Chung, J 1997A comparison of surgeons’ posture during laparoscopic and open surgical procedures.Surg Endosc2139142CrossRef Berguer, R, Rab, GT, Abu-Ghaida, H, Alarcon, A, Chung, J 1997A comparison of surgeons’ posture during laparoscopic and open surgical procedures.Surg Endosc2139142CrossRef
2.
go back to reference Berguer, R, Forkey, DL, Smith, WD 1999Ergonomic problems associated with laparoscopic surgery.Surg Endosc5466468 Berguer, R, Forkey, DL, Smith, WD 1999Ergonomic problems associated with laparoscopic surgery.Surg Endosc5466468
3.
go back to reference Berguer, R, Smith, WD, Chung, YH 2001Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery.Surg Endosc1012041207CrossRef Berguer, R, Smith, WD, Chung, YH 2001Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery.Surg Endosc1012041207CrossRef
4.
go back to reference Berquer, R, Smith, WD, Davis, S 2002An ergonomic study of the optimum operating table height for laparoscopic surgery.Surg Endosc3416421CrossRef Berquer, R, Smith, WD, Davis, S 2002An ergonomic study of the optimum operating table height for laparoscopic surgery.Surg Endosc3416421CrossRef
5.
go back to reference Cuschieri, A 1995Whither minimal access surgery: tribulations and expectations.Am J Surg1919 Cuschieri, A 1995Whither minimal access surgery: tribulations and expectations.Am J Surg1919
6.
go back to reference Emam, TA, Frank, TG, Hanna, GB, Cuschieri, A 2001Influence of handle design on the surgeon’s upper limb movements, muscle recruitment, and fatigue during endoscopic suturing.Surg Endosc7667672CrossRef Emam, TA, Frank, TG, Hanna, GB, Cuschieri, A 2001Influence of handle design on the surgeon’s upper limb movements, muscle recruitment, and fatigue during endoscopic suturing.Surg Endosc7667672CrossRef
7.
go back to reference Hanna, GB, Shimi, SM, Cuschieri, A 1998Task performance in endoscopic surgery is influenced by location of the image display.Ann Surg4481484CrossRef Hanna, GB, Shimi, SM, Cuschieri, A 1998Task performance in endoscopic surgery is influenced by location of the image display.Ann Surg4481484CrossRef
8.
go back to reference Horgan, LF, O’Rionda, DC, Doctor, N 1997Neoropraxia following laparoscopic procedures: an occupational injury.Min Inv Ther Allied Technol63335 Horgan, LF, O’Rionda, DC, Doctor, N 1997Neoropraxia following laparoscopic procedures: an occupational injury.Min Inv Ther Allied Technol63335
9.
go back to reference Nguyen, NT, Ho, HS, Smith, WD, Philipps, C, Lewis, C, Vera, RM, Berguer, R 2001An ergonomic evaluation of surgeons’ axial skeletal and upper extremity movements during laparoscopic and open surgery.Am J Surg6720724CrossRef Nguyen, NT, Ho, HS, Smith, WD, Philipps, C, Lewis, C, Vera, RM, Berguer, R 2001An ergonomic evaluation of surgeons’ axial skeletal and upper extremity movements during laparoscopic and open surgery.Am J Surg6720724CrossRef
10.
go back to reference Person, JG, Hodgson, AJ, Nagy, AG 2001Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery.Surg Endosc99971003 Person, JG, Hodgson, AJ, Nagy, AG 2001Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery.Surg Endosc99971003
11.
go back to reference Seitz, T, Balzulat, J, Bubb, H 2000Anthropometry and measurement of posture and motion.Int J Indust Ergonomics25447453CrossRef Seitz, T, Balzulat, J, Bubb, H 2000Anthropometry and measurement of posture and motion.Int J Indust Ergonomics25447453CrossRef
12.
go back to reference Veelen, MA, Jakimowicz, JJ, Goossens, RHM, Meijer, DW, Bussmann, JBJ 2002Evaluation of the usability of two types of image display systems during laparoscopy.Surg Endosc16674678CrossRefPubMed Veelen, MA, Jakimowicz, JJ, Goossens, RHM, Meijer, DW, Bussmann, JBJ 2002Evaluation of the usability of two types of image display systems during laparoscopy.Surg Endosc16674678CrossRefPubMed
Metadata
Title
Ergonomic assessment of the static stress confronted by surgeons during laparoscopic cholecystectomy
Authors
A. Vereczkei
H. Feussner
T. Negele
F. Fritzsche
T. Seitz
H. Bubb
Ö. P. Horváth
Publication date
01-07-2004
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 7/2004
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-003-9157-y

Other articles of this Issue 7/2004

Surgical Endoscopy 7/2004 Go to the issue

Announcements

New and notices