Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis—an animal study

Authors: Jacek Matys, Rafał Flieger, Gianluca Tenore, Kinga Grzech-Leśniak, Umberto Romeo, Marzena Dominiak

Published in: Lasers in Medical Science | Issue 3/2018

Login to get access

Abstract

It is important to identify factors that affect primary stability of orthodontic mini-implants because it determines the success of treatment. We assessed mini-implant primary stability (initial mechanical engagement with the bone) placed in pig jaws. We also assessed mini-implant insertion failure rate (mini-implant fracture, mini-implants to root contact). A total of 80 taper-shaped mini-implants (Absoanchor® Model SH1312-6; Dentos Inc., Daegu, Korea) 6 mm long with a diameter of 1.1 mm were used. Bone decortication was made before mini-implant insertion by means of three different methods: Group G1: Er:YAG laser (LiteTouch®, Light Instruments, Yokneam, Israel) at energy of 300 mJ, frequency 25 Hz, fluence 38.2 J/cm2, cooling 14 ml/min, tip 1.0 × 17 mm, distance 1 mm, time of irradiation 6 s; Group G2: drill (Hager & Meisinger GmbH, Hansemannstr, Germany); Group G3: piezosurgery (Piezotom Solo, Acteon, NJ, USA). In G4 group (control), mini-implants were driven by a self-drilling method. The primary stability of mini-implants was assessed by measuring damping characteristics between the implant and the tapping head of Periotest device (Gulden-Medizinteknik, Eschenweg, Modautal, Germany). The results in range between − 8 to + 9 allowed immediate loading. Significantly lower Periotest value was found in the control group (mean 0.59 ± 1.57, 95% CI 0.7, 2.4) as compared with Er:YAG laser (mean 4.44 ± 1.64, 95% CI 3.6, 5.3), piezosurgery (mean 17.92 ± 2.73, 95% CI 16.5, 19.3), and a drill (mean 5.91 ± 1.52, 95% CI 5.2, 6.6) (p < 0.05). The highest failure rate (33.3%) during mini-implant insertion was noted for self-drilling method (G4) as compared with G1, G2, and G3 groups (p < 0.05). The small diameter decortication by Er:YAG laser appeared to provide better primary stability as compared to drill and piezosurgery. Decortication of the cortical bone before mini-implant insertion resulted in reduced risk of implant fracture or injury of adjacent teeth. The high initial stability with a smaller diameter of the mini-implant resulted in increased risk of fracture, especially for a self-drilling method.
Literature
1.
go back to reference Park HS, Bae SM, Kyung HM, Sung JH (2001) Micro-implant anchorage for treatment of skeletal class I bialveolar protrusion. J Clin Orthod 35:417–422PubMed Park HS, Bae SM, Kyung HM, Sung JH (2001) Micro-implant anchorage for treatment of skeletal class I bialveolar protrusion. J Clin Orthod 35:417–422PubMed
2.
go back to reference Bae SM, Park HS, Kyung HM, Kwon OW, Sung JH (2002) Clinical application of micro-implant anchorage. J Clin Orthod 36:298–302PubMed Bae SM, Park HS, Kyung HM, Kwon OW, Sung JH (2002) Clinical application of micro-implant anchorage. J Clin Orthod 36:298–302PubMed
3.
go back to reference Baek SH, Kim BM, Kyung SH, Lim JK, Kim YH (2008) Success rate and risk factors associated with mini-implants reinstalled in the maxilla. Angle Orthod 78:895–901CrossRefPubMed Baek SH, Kim BM, Kyung SH, Lim JK, Kim YH (2008) Success rate and risk factors associated with mini-implants reinstalled in the maxilla. Angle Orthod 78:895–901CrossRefPubMed
5.
go back to reference Park JB, Kim EY, Paek J, Kook YA, Jeong DM, Cho IS, Nelson G (2014) Primary stability of self-drilling and self-tapping mini-implant in tibia of diabetes-induced rabbits. Int J Dent 429359:1–8CrossRef Park JB, Kim EY, Paek J, Kook YA, Jeong DM, Cho IS, Nelson G (2014) Primary stability of self-drilling and self-tapping mini-implant in tibia of diabetes-induced rabbits. Int J Dent 429359:1–8CrossRef
6.
go back to reference Gedrange T, Proff P, Bayerlein T, Landsberger P, Dietze S, Fanghanel J (2006) Histological and fluorescence microscopic examination of the bone/implant interface in orthodontic miniscrews (Mondeal). Folia Morphol (Warsz) 65:70–71 Gedrange T, Proff P, Bayerlein T, Landsberger P, Dietze S, Fanghanel J (2006) Histological and fluorescence microscopic examination of the bone/implant interface in orthodontic miniscrews (Mondeal). Folia Morphol (Warsz) 65:70–71
7.
go back to reference Nienkemper M, Wilmes B, Panayotidis A, Pauls A, Golubovic V, Schwarz F, Drescher D (2012) Measurement of mini-implant stability using resonance frequency analysis. Angle Orthod 83(2):230–238CrossRefPubMed Nienkemper M, Wilmes B, Panayotidis A, Pauls A, Golubovic V, Schwarz F, Drescher D (2012) Measurement of mini-implant stability using resonance frequency analysis. Angle Orthod 83(2):230–238CrossRefPubMed
8.
go back to reference Lukas D, Schulte W (1990) Periotest—a dynamic procedure for the diagnosis of the human periodontium. Clin Phys Physiol Meas 11:65–75CrossRefPubMed Lukas D, Schulte W (1990) Periotest—a dynamic procedure for the diagnosis of the human periodontium. Clin Phys Physiol Meas 11:65–75CrossRefPubMed
10.
go back to reference Marquezan M, Mattos CT, Sant’Anna EF, de Souza MM, Maia LC (2014) Does cortical thickness influence the primary stability of miniscrews?: a systematic review and meta-analysis. Angle Orthod 84(6):1093–1103CrossRefPubMed Marquezan M, Mattos CT, Sant’Anna EF, de Souza MM, Maia LC (2014) Does cortical thickness influence the primary stability of miniscrews?: a systematic review and meta-analysis. Angle Orthod 84(6):1093–1103CrossRefPubMed
11.
go back to reference Misch CE (1999) Contemporary implant dentistry, ed 2 edn. Mosby Inc. Table 8-1 (p.113) and Box 8-1, St. Louis, p 114 Misch CE (1999) Contemporary implant dentistry, ed 2 edn. Mosby Inc. Table 8-1 (p.113) and Box 8-1, St. Louis, p 114
12.
go back to reference Kong L, Hu K, Li D, Song Y, Yang J, Wu Z (2008) Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 23:65–74PubMed Kong L, Hu K, Li D, Song Y, Yang J, Wu Z (2008) Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 23:65–74PubMed
13.
go back to reference Wilmes B, Rademacher C, Olthoff G, Drescher D (2006) Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 67:162–174CrossRefPubMed Wilmes B, Rademacher C, Olthoff G, Drescher D (2006) Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 67:162–174CrossRefPubMed
14.
go back to reference Shah AH, Behrents RG, Kim KB, Kyung HM, Buschang PH (2012) Effects of screw and host factors on insertion torque and pullout strength. Angle Orthod 2:603–610CrossRef Shah AH, Behrents RG, Kim KB, Kyung HM, Buschang PH (2012) Effects of screw and host factors on insertion torque and pullout strength. Angle Orthod 2:603–610CrossRef
15.
go back to reference Yi Lin S, Mimi Y, Ming Tak C, Kelvin Weng Chiong F, Hung Chew W (2015) A study of success rate of miniscrew implants as temporary anchorage devices in Singapore. Int J Dent 2015:294670CrossRefPubMedPubMedCentral Yi Lin S, Mimi Y, Ming Tak C, Kelvin Weng Chiong F, Hung Chew W (2015) A study of success rate of miniscrew implants as temporary anchorage devices in Singapore. Int J Dent 2015:294670CrossRefPubMedPubMedCentral
16.
go back to reference Novsak D, Zrinski MT, Spalj S (2015) Machine-driven versus manual insertion mode: influence on primary stability of orthodontic mini-implants. Implant Dent 24(1):31–36PubMed Novsak D, Zrinski MT, Spalj S (2015) Machine-driven versus manual insertion mode: influence on primary stability of orthodontic mini-implants. Implant Dent 24(1):31–36PubMed
17.
go back to reference Aoki A, Takasaki AA, Nagai S, Yoshida I, Zeredo JL, Mizutani K, Sasaki KM, Schwarz F, Eguro T, Izumi Y (2008) Current status of clinical laser applications in periodontal therapy. Gen Dent 56(7):674PubMed Aoki A, Takasaki AA, Nagai S, Yoshida I, Zeredo JL, Mizutani K, Sasaki KM, Schwarz F, Eguro T, Izumi Y (2008) Current status of clinical laser applications in periodontal therapy. Gen Dent 56(7):674PubMed
18.
go back to reference Borzabadi-Farahani A (2017) The adjunctive soft-tissue diode laser in orthodontics. Compend Contin Educ Dent 38(eBook 5):e18PubMed Borzabadi-Farahani A (2017) The adjunctive soft-tissue diode laser in orthodontics. Compend Contin Educ Dent 38(eBook 5):e18PubMed
20.
go back to reference Maria O, Ana M, Andreu P (2008) Primary stability of microscrews based on their diameter, length, shape and area of insertion: an experimental study with Periotest. Prog Orthod 9(2):82–88PubMed Maria O, Ana M, Andreu P (2008) Primary stability of microscrews based on their diameter, length, shape and area of insertion: an experimental study with Periotest. Prog Orthod 9(2):82–88PubMed
21.
go back to reference Motoyoshi M, Yoshida T, Ono A, Shimizu N (2007) Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants 22(5):779–784PubMed Motoyoshi M, Yoshida T, Ono A, Shimizu N (2007) Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants 22(5):779–784PubMed
22.
go back to reference Cehreli S, Arman-Ozcirpici A (2012) Primary stability and histomorphometric bone-implant contact of self-drilling and selftapping orthodontic microimplants. Am J Orthod Dentofac Orthop 141:187–195CrossRef Cehreli S, Arman-Ozcirpici A (2012) Primary stability and histomorphometric bone-implant contact of self-drilling and selftapping orthodontic microimplants. Am J Orthod Dentofac Orthop 141:187–195CrossRef
23.
go back to reference Son S, Motoyoshi M, Uchida Y, Shimizu N (2014) Comparative study of the primary stability of self-drilling and self-tapping orthodontic miniscrews. Am J Orthod Dentofac Orthop 145(4):480–485CrossRef Son S, Motoyoshi M, Uchida Y, Shimizu N (2014) Comparative study of the primary stability of self-drilling and self-tapping orthodontic miniscrews. Am J Orthod Dentofac Orthop 145(4):480–485CrossRef
24.
go back to reference Yoo SH, Park YC, Hwang CJ, Kim JY, Choi EH, Cha JY (2014) A comparison of tapered and cylindrical miniscrew stability. Eur J Orthod 36(5):557–562CrossRefPubMed Yoo SH, Park YC, Hwang CJ, Kim JY, Choi EH, Cha JY (2014) A comparison of tapered and cylindrical miniscrew stability. Eur J Orthod 36(5):557–562CrossRefPubMed
25.
go back to reference Dilek O, Tezulas E, Dincel M (2008) Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105(2):e20–e27CrossRefPubMed Dilek O, Tezulas E, Dincel M (2008) Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105(2):e20–e27CrossRefPubMed
26.
go back to reference Romeo U, Del Vecchio A, Palata G, Tenore G, Visca P, Maggiore C (2009) Bone damage induced by different cutting instruments: an in vitro study. Braz Dent J 20(2):162–168CrossRefPubMed Romeo U, Del Vecchio A, Palata G, Tenore G, Visca P, Maggiore C (2009) Bone damage induced by different cutting instruments: an in vitro study. Braz Dent J 20(2):162–168CrossRefPubMed
27.
go back to reference Matys J, Flieger R, Dominiak M (2016)Assessment of temperature rise and time of alveolar ridge splitting by means of Er:YAG laser, piezosurgery, and surgical saw: an ex vivo study. BioMed Res Int Article ID 9654975, 8 pages. https://doi.org/10.1155/2016/9654975 Matys J, Flieger R, Dominiak M (2016)Assessment of temperature rise and time of alveolar ridge splitting by means of Er:YAG laser, piezosurgery, and surgical saw: an ex vivo study. BioMed Res Int Article ID 9654975, 8 pages. https://​doi.​org/​10.​1155/​2016/​9654975
29.
go back to reference Truhlar RS, Orenstein IH, Morris HF, Ochi S (1997) Distribution of bone quality in patients receiving endosseous dental implants. J Oral Maxillofac Surg 55(12):38–45CrossRefPubMed Truhlar RS, Orenstein IH, Morris HF, Ochi S (1997) Distribution of bone quality in patients receiving endosseous dental implants. J Oral Maxillofac Surg 55(12):38–45CrossRefPubMed
30.
go back to reference Heidemann W, Gerlach KL, Grobel KH, Kollner HG (1998) Drill free screws: a new form of osteosynthesis screw. J Craniomaxillofac Surg 26:163–168CrossRefPubMed Heidemann W, Gerlach KL, Grobel KH, Kollner HG (1998) Drill free screws: a new form of osteosynthesis screw. J Craniomaxillofac Surg 26:163–168CrossRefPubMed
31.
go back to reference Mischkowski RA, Kneuertz P, Florvaag B, Lazar F, Koebke J, Zoller JE (2008) Biomechanical comparison of four different miniscrew types for skeletal anchorage in the mandibulo-maxillary area. Int J Oral Maxillofac Surg 37:948–954CrossRefPubMed Mischkowski RA, Kneuertz P, Florvaag B, Lazar F, Koebke J, Zoller JE (2008) Biomechanical comparison of four different miniscrew types for skeletal anchorage in the mandibulo-maxillary area. Int J Oral Maxillofac Surg 37:948–954CrossRefPubMed
32.
go back to reference Hitchon PW, Brenton MD, Coppes JK, From AM, Torner JC (2003) Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws. Spine 28:9–13CrossRefPubMed Hitchon PW, Brenton MD, Coppes JK, From AM, Torner JC (2003) Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws. Spine 28:9–13CrossRefPubMed
Metadata
Title
Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis—an animal study
Authors
Jacek Matys
Rafał Flieger
Gianluca Tenore
Kinga Grzech-Leśniak
Umberto Romeo
Marzena Dominiak
Publication date
01-04-2018
Publisher
Springer London
Published in
Lasers in Medical Science / Issue 3/2018
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-017-2381-9

Other articles of this Issue 3/2018

Lasers in Medical Science 3/2018 Go to the issue