Skip to main content
Top
Published in: Neuroradiology 4/2005

01-04-2005 | Interventional Neuroradiology

Endovascular occlusion of direct carotid cavernous fistula with detachable balloons: usefulness of 3D angiography

Authors: Bae Ju Kwon, Moon Hee Han, Hyun-Seung Kang, Kee-Hyun Chang

Published in: Neuroradiology | Issue 4/2005

Login to get access

Abstract

The objective of this study is to show rotational 3D angiography findings and their usefulness in the occlusion of carotid cavernous fistulas (CCFs) using detachable balloons. Five patients with direct CCF were retrospectively reviewed for details of interventional procedures and 2D and 3D angiography findings. Pretherapeutic 2D and 3D angiograms (n=2) were compared to evaluate the size of the fistula and the relative size of the cavernous sinus with respect to the fistula. Postinflation-predetachment (n=3) and postdetachment (n=4) 2D and 3D angiograms were compared in each stage to evaluate the relative location of the balloon to the internal carotid artery (ICA), presence of a pseudoaneurysm, and relative size of the balloon to the fistula. Pretherapeutic 2D and 3D angiograms were equally effective in showing the fistula and relative size of the cavernous sinus. But, 3D angiography with “cut images” at arbitrary viewing angles clearly visualized the 3D relations between the ICA, fistula, and cavernous sinus. Both postinflation-predetachment 2D and 3D images in two patients equally showed a contrast-filled pseudoaneurysm outside the ICA and intraluminal location of the balloon. However, only the 3D images showed no difference in size of the balloon compared with the fistula, which was relevant to traction-induced instability in the remaining one patient. Both postdetachment 2D and 3D angiograms were equal in terms of showing ICA compromise (60%) in one patient and an extraluminal balloon location with complete fistular occlusion in two patients. In the remainder, a small pseudoaneurysm was identified only on 3D images. Three-dimensional angiography is a useful imaging tool for capturing the complex perifistular anatomy in the pretherapeutic stage, and for providing detailed information about the degree of balloon inflation and its location, the presence of a pseudoaneurysm, and the expected traction-induced instability in the predetachment stage. Postinflation-predetachment 3D angiography may therefore offer a chance to correct an erroneous manipulation that would otherwise lead to an incomplete procedural outcome and disastrous balloon migration.
Literature
1.
go back to reference Barrow DL, Fleischer AS, Hoffman JC (1982) Complications of detachable balloon catheter technique in the treatment of traumatic intracranial arteriovenous fistulas. J Neurosurg 56:396–403 Barrow DL, Fleischer AS, Hoffman JC (1982) Complications of detachable balloon catheter technique in the treatment of traumatic intracranial arteriovenous fistulas. J Neurosurg 56:396–403
2.
go back to reference Lewis AI, Tomsick TA, Tew JM (1995) Management of 100 consecutive direct carotid-cavernous fistulas: results of treatment with detachable balloons. Neurosurgery 36:239–245 Lewis AI, Tomsick TA, Tew JM (1995) Management of 100 consecutive direct carotid-cavernous fistulas: results of treatment with detachable balloons. Neurosurgery 36:239–245
3.
go back to reference Debrun G, Lacour P, Vinuela F, Fox A, Drake CG, Caron JP (1981) Treatment of 54 traumatic carotid-cavernous fistulas. J Neurosurg 55:678–692 Debrun G, Lacour P, Vinuela F, Fox A, Drake CG, Caron JP (1981) Treatment of 54 traumatic carotid-cavernous fistulas. J Neurosurg 55:678–692
4.
go back to reference Langford KH, Vitek JJ, Zeiger E (1983) Migration of detachable mini-balloon from the ICA causing occlusion of the MCA. J Neurosurg 58:430–434 Langford KH, Vitek JJ, Zeiger E (1983) Migration of detachable mini-balloon from the ICA causing occlusion of the MCA. J Neurosurg 58:430–434
5.
go back to reference Chalif DJ, Flamm ES, Berenstein A, Choi IS (1983) Microsurgical removal of a balloon embolus to the internal carotid artery. J Neurosurg 58:112–116 Chalif DJ, Flamm ES, Berenstein A, Choi IS (1983) Microsurgical removal of a balloon embolus to the internal carotid artery. J Neurosurg 58:112–116
6.
go back to reference Hochmuth A, Spetzger U, Schumacher M (2002) Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms. Am J Neuroradiol 23:1199–1205 Hochmuth A, Spetzger U, Schumacher M (2002) Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms. Am J Neuroradiol 23:1199–1205
7.
go back to reference Kiyosue H, Tanoue S, Okahara M, Hori Y, Nakamura T, Nagatomi H, Mori H (2002) Anatomic features predictive of complete aneurysm occlusion can be determined with three-dimensional digital subtraction angiography. Am J Neuroradiol 23:1206–1213 Kiyosue H, Tanoue S, Okahara M, Hori Y, Nakamura T, Nagatomi H, Mori H (2002) Anatomic features predictive of complete aneurysm occlusion can be determined with three-dimensional digital subtraction angiography. Am J Neuroradiol 23:1206–1213
8.
go back to reference Anxionnat R, Bracard S, Ducrocq X et al (2001) Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment. Radiology 218:799–808PubMed Anxionnat R, Bracard S, Ducrocq X et al (2001) Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment. Radiology 218:799–808PubMed
9.
go back to reference Sugahara T, Korogi Y, Nakashima K, Hamatake S, Honda S, Takahashi M (2002) Comparison of 2D and 3D digital subraction angiography in evaluation of intracranial aneurysms. Am J Neuroradiol 23:1545–1552 Sugahara T, Korogi Y, Nakashima K, Hamatake S, Honda S, Takahashi M (2002) Comparison of 2D and 3D digital subraction angiography in evaluation of intracranial aneurysms. Am J Neuroradiol 23:1545–1552
10.
go back to reference Serbinenko FA (1974) Balloon catheterization and occlusion of major cerebral vessels. J Neurosurg 41:125–145 Serbinenko FA (1974) Balloon catheterization and occlusion of major cerebral vessels. J Neurosurg 41:125–145
11.
go back to reference Halbach VV, Higashida RT, Barnwell SL, Dowd CF, Hieshima GB (1991) Transarterial platinum coil embolization of carotid-cavernous fistulas. Am J Neuroradiol 12(3):429–433 Halbach VV, Higashida RT, Barnwell SL, Dowd CF, Hieshima GB (1991) Transarterial platinum coil embolization of carotid-cavernous fistulas. Am J Neuroradiol 12(3):429–433
12.
go back to reference Bavinzski G, Killer M, Gruber A, Richling B (1997) Treatment of post-traumatic carotico-cavernous fistulae using electrolytically detachable coils: technical aspects and preliminary experience. Neuroradiology 39(2):81–5 Bavinzski G, Killer M, Gruber A, Richling B (1997) Treatment of post-traumatic carotico-cavernous fistulae using electrolytically detachable coils: technical aspects and preliminary experience. Neuroradiology 39(2):81–5
13.
go back to reference Kendal B (1983) Results of treatment of AVF with the Debrun technique. Am J Neuroradiol 4:405–408 Kendal B (1983) Results of treatment of AVF with the Debrun technique. Am J Neuroradiol 4:405–408
14.
go back to reference Higashida R, Halbach V, Tsai FY et al (1989) Interventional neurovascular treatment of traumatic carotid cavernous fistula with detachable balloon. Am J Roentgenol 153:577–582 Higashida R, Halbach V, Tsai FY et al (1989) Interventional neurovascular treatment of traumatic carotid cavernous fistula with detachable balloon. Am J Roentgenol 153:577–582
15.
go back to reference Graeb DA, Robertson WD, Lapointe JS, Nugent RA (1985) Avoiding intraarterial balloon detachment in the treatment of posttraumatic carotid-cavernous fistulae with detachable balloons. Am J Neuroradiol 6:602–605 Graeb DA, Robertson WD, Lapointe JS, Nugent RA (1985) Avoiding intraarterial balloon detachment in the treatment of posttraumatic carotid-cavernous fistulae with detachable balloons. Am J Neuroradiol 6:602–605
16.
go back to reference Abe T, Hirohata M, Tanaka N et al (2002) Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm. Am J Neuroradiol 23:686–688 Abe T, Hirohata M, Tanaka N et al (2002) Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm. Am J Neuroradiol 23:686–688
Metadata
Title
Endovascular occlusion of direct carotid cavernous fistula with detachable balloons: usefulness of 3D angiography
Authors
Bae Ju Kwon
Moon Hee Han
Hyun-Seung Kang
Kee-Hyun Chang
Publication date
01-04-2005
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 4/2005
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-005-1337-0

Other articles of this Issue 4/2005

Neuroradiology 4/2005 Go to the issue

Society News

ESNR - April 2005