Abstract

Background

Preclinical and early clinical external pelvic stabilization using commercially available devices has become common in trauma patient care. Thus, in the emergency department an increasing number of patients will undergo radiographic evaluation of the externally stabilized pelvis to exclude injuries. While reports exist where injuries to the pelvis were elusive to radiological examination due to the pelvic immobilization we elaborate on an algorithm to remove an external pelvic stabilizing device, prevent delayed diagnosis of pelvic disruption and thus increase patient safety.

Case presentation

We report on two patients with external pelvic stabilization presenting with an inconspicuous pubic symphysis on initial pelvic computed tomography scans. The first patient was an otherwise healthy 51-year old male being run over by his own car. He received external pelvic stabilization in the emergency department. The second patient was a 36-year old male falling from a ladder. In this patient external pelvic stabilization was performed at the scene. In the first patient no pelvic injury was obvious on computed tomography. In the second patient pelvic fractures were diagnosed, yet the presentation of the pubic symphysis appeared normal. Nevertheless, complete symphyseal disruption was diagnosed in both of them upon removal of the external pelvic stabilization and consequently required internal fixation.

Conclusion

Based on our experience we propose an algorithm to “clear the initially immobilized pelvis” in an effort to minimize the risk of missing a serious pelvic injury and increase patient safety. This is of significant importance to orthopedic trauma surgeons and emergency physicians taking care of injured patients.
Literature
2.
go back to reference Gänsslen A, Pohlemann T, Paul C, Lobenhoffer P, Tscherne H. Epidemiology of pelvic ring injuries. Injury. 1996;27 Suppl 1:13–20.CrossRef Gänsslen A, Pohlemann T, Paul C, Lobenhoffer P, Tscherne H. Epidemiology of pelvic ring injuries. Injury. 1996;27 Suppl 1:13–20.CrossRef
3.
go back to reference Hauschild O, Strohm PC, Culemann U, Pohlemann T, Suedkamp NP, Koestler W, et al. Mortality in patients with pelvic fractures: results from the German pelvic injury register. J Trauma. 2008;64:449–55.CrossRefPubMed Hauschild O, Strohm PC, Culemann U, Pohlemann T, Suedkamp NP, Koestler W, et al. Mortality in patients with pelvic fractures: results from the German pelvic injury register. J Trauma. 2008;64:449–55.CrossRefPubMed
4.
go back to reference Evans JA, van Wessem KJ, McDougall D, Lee KA, Lyons T, Balogh ZJ. Epidemiology of traumatic deaths: comprehensive population-based assessment. World J Surg. 2010;34:158–63.CrossRefPubMed Evans JA, van Wessem KJ, McDougall D, Lee KA, Lyons T, Balogh ZJ. Epidemiology of traumatic deaths: comprehensive population-based assessment. World J Surg. 2010;34:158–63.CrossRefPubMed
5.
go back to reference Knops SP, Schep NW, Spoor CW, van Riel MP, Spanjersberg WR, Kleinrensink GJ, et al. Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study. J Bone Joint Surg Am. 2011;93:230–40.CrossRefPubMed Knops SP, Schep NW, Spoor CW, van Riel MP, Spanjersberg WR, Kleinrensink GJ, et al. Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study. J Bone Joint Surg Am. 2011;93:230–40.CrossRefPubMed
6.
go back to reference Pizanis A, Pohlemann T, Burkhardt M, Aghayev E, Holstein JH. Emergency stabilization of the pelvic ring: clinical comparison between three different techniques. Injury. 2013;44:1760–4.CrossRefPubMed Pizanis A, Pohlemann T, Burkhardt M, Aghayev E, Holstein JH. Emergency stabilization of the pelvic ring: clinical comparison between three different techniques. Injury. 2013;44:1760–4.CrossRefPubMed
7.
go back to reference MacLeod M, Powell JN. Evaluation of pelvic fractures. Clinical and radiologic. Orthop Clin North Am. 1997;28:299–319.CrossRefPubMed MacLeod M, Powell JN. Evaluation of pelvic fractures. Clinical and radiologic. Orthop Clin North Am. 1997;28:299–319.CrossRefPubMed
8.
go back to reference American College of Surgeons. Advanced Trauma Life Support ATLS. 9th ed. Chicago: American College of Surgeons; 2012. American College of Surgeons. Advanced Trauma Life Support ATLS. 9th ed. Chicago: American College of Surgeons; 2012.
9.
go back to reference Acute TM, Fractures P. I. Causation and classification. J Am Acad Orthop Surg. 1996;4:143–51.CrossRef Acute TM, Fractures P. I. Causation and classification. J Am Acad Orthop Surg. 1996;4:143–51.CrossRef
10.
go back to reference Hilty MP, Behrendt I, Benneker LM, Martinolli L, Stoupis C, Buggy DJ, et al. Pelvic radiography in ATLS algorithms: a diminishing role? World J Emerg Surg. 2008;3:11.CrossRefPubMedPubMedCentral Hilty MP, Behrendt I, Benneker LM, Martinolli L, Stoupis C, Buggy DJ, et al. Pelvic radiography in ATLS algorithms: a diminishing role? World J Emerg Surg. 2008;3:11.CrossRefPubMedPubMedCentral
11.
go back to reference Herzog C, Ahle H, Mack MG, Maier B, Schwarz W, Zangos S, et al. Traumatic injuries of the pelvis and thoracic and lumbar spine: does thin-slice multidetector-row CT increase diagnostic accuracy? Eur Radiol. 2004;14:1751–60.PubMed Herzog C, Ahle H, Mack MG, Maier B, Schwarz W, Zangos S, et al. Traumatic injuries of the pelvis and thoracic and lumbar spine: does thin-slice multidetector-row CT increase diagnostic accuracy? Eur Radiol. 2004;14:1751–60.PubMed
12.
go back to reference Bottlang M, Simpson T, Sigg J, Krieg JC, Madey SM, Long WB. Noninvasive reduction of open-book pelvic fractures by circumferential compression. J Orthop Trauma. 2002;16:367–73.CrossRefPubMed Bottlang M, Simpson T, Sigg J, Krieg JC, Madey SM, Long WB. Noninvasive reduction of open-book pelvic fractures by circumferential compression. J Orthop Trauma. 2002;16:367–73.CrossRefPubMed
13.
go back to reference Qureshi A, McGee A, Cooper JP, Porter KM. Reduction of the posterior pelvic ring by non-invasive stabilisation: a report of two cases. Emerg Med J. 2005;22:885–6.CrossRefPubMedPubMedCentral Qureshi A, McGee A, Cooper JP, Porter KM. Reduction of the posterior pelvic ring by non-invasive stabilisation: a report of two cases. Emerg Med J. 2005;22:885–6.CrossRefPubMedPubMedCentral
14.
go back to reference Vermeulen B, Peter R, Hoffmeyer P, Unger PF. Prehospital stabilization of pelvic dislocations: a new strap belt to provide temporary hemodynamic stabilization. Swiss Surg. 1999;5:43–6.CrossRefPubMed Vermeulen B, Peter R, Hoffmeyer P, Unger PF. Prehospital stabilization of pelvic dislocations: a new strap belt to provide temporary hemodynamic stabilization. Swiss Surg. 1999;5:43–6.CrossRefPubMed
Metadata
Title
Emergency radiological examination of the externally stabilized pelvis – there is a catch to it: lessons learned from two cases with symphyseal disruption despite initial inconspicuous computed tomography
Authors
Jörg Bayer
Thorsten Hammer
Dirk Maier
Norbert Paul Südkamp
Oliver Hauschild
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Surgery / Issue 1/2016
Electronic ISSN: 1471-2482
DOI
https://doi.org/10.1186/s12893-016-0126-5

Other articles of this Issue 1/2016

BMC Surgery 1/2016 Go to the issue