01-01-2011 | Original Article
Elevated inflammatory mediators and pulmonary hypertension after applying an extracorporeal circuit in a neonatal sepsis model
Published in: Pediatric Surgery International | Issue 1/2011
Login to get accessAbstract
Purpose
We aimed to study the changes in cytokines, oxidative mediators, and pulmonary blood pressure in a neonatal sepsis model when applying an extracorporeal circuit (ECC).
Methods
Of 28 anesthetized and mechanically ventilated 3-day-old piglets, 14 underwent cecal ligation and perforation (CLP), of which 7 underwent ECC for 3 h from 3 to 6 h after CLP. The remaining 14 were sham, of which 7 underwent ECC. Serum interleukin (IL)-6, IL-10, tumor necrosis factor (TNF), interferon gamma (IFN-γ), total hydroperoxide (TH), nitric oxide metabolites (NOx), and mean pulmonary arterial blood pressure (mPAP)/mean arterial blood pressure (mABP) ratio were measured at pre-CLP and at 3, 6, and 9 h in the CLP groups, and continued in the sham groups at 12, 15, 18, and 24 h.
Results
The CLP group with ECCs compared to the CLP group without it showed higher levels of serum IL-6, IL-10, and NOx at 6 h and higher levels of serum TH at 6 and 9 h. The sham group with ECCs compared to the one without it showed higher levels of serum IL-6 and IL-10 at 12, 15, and 18 h, TH at 6 and 9 h, TNF at 6 h, and IFN-γ at 9 h. The mPAP/mABP ratios in the CLP group with ECCs were higher compared to the CLP group without it at 6 and 9 h.
Conclusion
Applying ECCs provoked a window of cytokines, free radicals elevation, and pulmonary hypertension which could be hazardous in critically ill newborns.