Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 4/2022

10-07-2021 | Electroencephalography | Original Research

Processed electroencephalography: impact of patient age and surgical position on intraoperative processed electroencephalogram monitoring of burst-suppression

Authors: D. Pleasants, R. Zak, L. H. Ashbrook, L. Zhang, C. Tang, D. Tran, M. Wang, S. Tabatabai, J. M. Leung

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2022

Login to get access

Abstract

We previously reported that processed EEG underestimated the amount of burst suppression compared to off-line visual analysis. We performed a follow-up study to evaluate the reasons for the discordance. Forty-five patients were monitored intraoperatively with processed EEG. A computer algorithm was used to convert the SedLine® (machine)-generated burst suppression ratio into a raw duration of burst suppression. The reference standard was a precise off-line measurement by two neurologists. We measured other potential variables that may affect machine accuracy such as age, surgery position, and EEG artifacts. Overall, the median duration of bust suppression for all study subjects was 15.4 min (Inter-quartile Range [IQR] = 1.0–20.1) for the machine vs. 16.1 min (IQR = 0.3–19.7) for the neurologists’ assessment; the 95% limits of agreement fall within − 4.86 to 5.04 s for individual 30-s epochs. EEG artifacts did not affect the concordance between the two methods. For patients in prone surgical position, the machine estimates had significantly lower overall sensitivity (0.86 vs. 0.97; p = 0.038) and significantly wider limits of agreement ([− 4.24, 3.82] seconds vs. [− 1.36, 1.13] seconds, p = 0.001) than patients in supine position. Machine readings for younger patients (age < 65 years) had higher sensitivity (0.96 vs 0.92; p = 0.021) and specificity (0.99 vs 0.88; p = 0.007) for older patients. The duration of burst suppression estimated by the machine generally had good agreement compared with neurologists’ estimation using a more precise off-line measurement. Factors that affected the concordance included patient age and position during surgery, but not EEG artifacts.
Literature
4.
go back to reference Pedemonte JC, Plummer GS, Chamadia S, Locascio JJ, Hahm E, Ethridge B, Gitlin J, Ibala R, Mekonnen J, Colon KM, Westover MB, D’Alessandro DA, Tolis G, Houle T, Shelton KT, Qu J, Akeju O. Electroencephalogram burst-suppression during cardiopulmonary bypass in elderly patients mediates postoperative delirium. Anesthesiology. 2020;133:280–92. https://doi.org/10.1097/ALN.0000000000003328.CrossRefPubMed Pedemonte JC, Plummer GS, Chamadia S, Locascio JJ, Hahm E, Ethridge B, Gitlin J, Ibala R, Mekonnen J, Colon KM, Westover MB, D’Alessandro DA, Tolis G, Houle T, Shelton KT, Qu J, Akeju O. Electroencephalogram burst-suppression during cardiopulmonary bypass in elderly patients mediates postoperative delirium. Anesthesiology. 2020;133:280–92. https://​doi.​org/​10.​1097/​ALN.​0000000000003328​.CrossRefPubMed
12.
go back to reference Britton JW, Frey LC, Hopp JL, Korb P, Koubeissi MZ, Lievens WE, Pestana-Knight EM, St. Louis EK. Electroencephalography (EEG): an introductory Text and Atlas of normal and abnormal findings in adults, children, and infants [internet]. Chicago: American Epilepsy Society; 2016. Britton JW, Frey LC, Hopp JL, Korb P, Koubeissi MZ, Lievens WE, Pestana-Knight EM, St. Louis EK. Electroencephalography (EEG): an introductory Text and Atlas of normal and abnormal findings in adults, children, and infants [internet]. Chicago: American Epilepsy Society; 2016.
19.
go back to reference Wildes TS, Mickle AM, Ben Abdallah A, Maybrier HR, Oberhaus J, Budelier TP, Kronzer A, McKinnon AL, Park D, Torres BA, Graetz TJ, Emmert DA, Palanca BJ, Goswami S, Jordan K, Lin N, Fritz BA, Stevens TW, Jacobsohn E, Schmitt EM, Inouye SK, Stark S, Lenze EJ, Avidan MJ, ER Group. Effect of electroencephalography-guided anesthetic administration on postoperative delirium among older adults undergoing major surgery: the ENGAGES randomized clinical trial. JAMA. 2019;321:473–83. https://doi.org/10.1001/jama.2018.22005. Wildes TS, Mickle AM, Ben Abdallah A, Maybrier HR, Oberhaus J, Budelier TP, Kronzer A, McKinnon AL, Park D, Torres BA, Graetz TJ, Emmert DA, Palanca BJ, Goswami S, Jordan K, Lin N, Fritz BA, Stevens TW, Jacobsohn E, Schmitt EM, Inouye SK, Stark S, Lenze EJ, Avidan MJ, ER Group. Effect of electroencephalography-guided anesthetic administration on postoperative delirium among older adults undergoing major surgery: the ENGAGES randomized clinical trial. JAMA. 2019;321:473–83. https://​doi.​org/​10.​1001/​jama.​2018.​22005.
Metadata
Title
Processed electroencephalography: impact of patient age and surgical position on intraoperative processed electroencephalogram monitoring of burst-suppression
Authors
D. Pleasants
R. Zak
L. H. Ashbrook
L. Zhang
C. Tang
D. Tran
M. Wang
S. Tabatabai
J. M. Leung
Publication date
10-07-2021
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2022
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-021-00741-w

Other articles of this Issue 4/2022

Journal of Clinical Monitoring and Computing 4/2022 Go to the issue