Abstract

Background

Most drugs with systemic bioavailability have to undergo a thorough QT (TQT) study, which includes a pharmacologic positive control. A set of QTc-quality tests was recently proposed with the possible aim of removing the need for a positive control.

Objective

We evaluated the influence of QT measurement and QTc computation methodology on the proposed QTc-quality tests.

Methods

The baseline ECG waveforms and fiducial points were retrieved from 34 crossover TQT studies that had full-day baseline ECGs prior to each study period. The QT measurement methodology and recorder type were retrieved from study reports. The influence of QTc computation methodology was investigated by applying the pattern-matching technique and/or using the 10-s average heart rate.

Results

There were no statistical differences in any QTc-quality test values between studies using continuous or 10-s bedside recordings and, in a subset of the quality test, an increase of data quality for semi-automatically read studies compared with those manually read (p < 0.01). There was a significant improvement (p < 0.01) in all the QTc-quality test values for QTc measurements obtained by using pattern matching with or without 10-s average heart rate in comparison to the original QTc measurements.

Conclusion

The findings suggest that QTc quality is mostly driven by the QTc measurement methodology rather than other study-related factors.
Literature
1.
go back to reference ICH. Guidance for Industry E14 clinical evaluation of QT/QTc interval prolongation and proarrhythmic potential for non-antiarrhythmic drugs. 2005. ICH. Guidance for Industry E14 clinical evaluation of QT/QTc interval prolongation and proarrhythmic potential for non-antiarrhythmic drugs. 2005.
2.
go back to reference ICH. Guidance for industry E14 clinical evaluation of QT/QTc interval prolongation and proarrhythmic potential for non-antiarrhythmic drugs. Questions and answers; 2008. ICH. Guidance for industry E14 clinical evaluation of QT/QTc interval prolongation and proarrhythmic potential for non-antiarrhythmic drugs. Questions and answers; 2008.
3.
go back to reference Malik M, Zhang J, Johannesen L, Hnatkova K, Garnett C. Assessing electrocardiographic data quality and possible replacement of pharmacological positive control in thorough QT/QTc studies by investigations of drug-free QTc stability. Heart Rhythm. 2011;8(11):1777–85.PubMedCrossRef Malik M, Zhang J, Johannesen L, Hnatkova K, Garnett C. Assessing electrocardiographic data quality and possible replacement of pharmacological positive control in thorough QT/QTc studies by investigations of drug-free QTc stability. Heart Rhythm. 2011;8(11):1777–85.PubMedCrossRef
4.
5.
go back to reference Hnatkova K, Smetana P, Toman O, Bauer A, Schmidt G, Malik M. Systematic comparisons of electrocardiographic morphology increase the precision of QT interval measurement. Pacing Clin Electrophysiol. 2009;32(1):119–30.PubMedCrossRef Hnatkova K, Smetana P, Toman O, Bauer A, Schmidt G, Malik M. Systematic comparisons of electrocardiographic morphology increase the precision of QT interval measurement. Pacing Clin Electrophysiol. 2009;32(1):119–30.PubMedCrossRef
6.
go back to reference Fridericia LS. Die Systolendauer im Elektrokardiogramm bei normalen Menschen und bei Herzkranken. Acta Med Scand. 1920;54(1):170. Fridericia LS. Die Systolendauer im Elektrokardiogramm bei normalen Menschen und bei Herzkranken. Acta Med Scand. 1920;54(1):170.
7.
go back to reference Badilini F, Vaglio M, Sarapa N. Automatic extraction of ECG strips from continuous 12-lead Holter recordings for QT analysis at prescheduled versus optimized time points. Ann Noninvasive Electrocardiol. 2009;14(Suppl 1):S22–9.PubMedCrossRef Badilini F, Vaglio M, Sarapa N. Automatic extraction of ECG strips from continuous 12-lead Holter recordings for QT analysis at prescheduled versus optimized time points. Ann Noninvasive Electrocardiol. 2009;14(Suppl 1):S22–9.PubMedCrossRef
8.
go back to reference Meyer O, Ferber G, Greig G, Holzgrefe HH. Pattern recognition analysis of digital ECGs: decreased QT measurement error and improved precision compared to semi-automated methods. J Electrocardiol. 2013;46(2):118–25.PubMedCrossRef Meyer O, Ferber G, Greig G, Holzgrefe HH. Pattern recognition analysis of digital ECGs: decreased QT measurement error and improved precision compared to semi-automated methods. J Electrocardiol. 2013;46(2):118–25.PubMedCrossRef
9.
go back to reference Malik M, Hnatkova K, Novotny T, Schmidt G. Subject-specific profiles of QT/RR hysteresis. Am J Physiol Heart Circ Physiol. 2008;295(6):H2356–63.PubMedCrossRef Malik M, Hnatkova K, Novotny T, Schmidt G. Subject-specific profiles of QT/RR hysteresis. Am J Physiol Heart Circ Physiol. 2008;295(6):H2356–63.PubMedCrossRef
10.
go back to reference Natekar M, Hingorani P, Gupta P, Karnad DR, Kothari S, de Vries M, et al. Effect of number of replicate electrocardiograms recorded at each time point in a thorough QT study on sample size and study cost. J Clin Pharmacol. 2011;51(6):908–14.PubMedCrossRef Natekar M, Hingorani P, Gupta P, Karnad DR, Kothari S, de Vries M, et al. Effect of number of replicate electrocardiograms recorded at each time point in a thorough QT study on sample size and study cost. J Clin Pharmacol. 2011;51(6):908–14.PubMedCrossRef
Metadata
Title
Electrocardiographic Data Quality in Thorough QT/QTc Studies
Authors
Lars Johannesen
Christine Garnett
Marek Malik
Publication date
01-03-2014
Publisher
Springer International Publishing
Published in
Drug Safety / Issue 3/2014
Print ISSN: 0114-5916
Electronic ISSN: 1179-1942
DOI
https://doi.org/10.1007/s40264-014-0140-4

Other articles of this Issue 3/2014

Drug Safety 3/2014 Go to the issue