Published in: Archives of Orthopaedic and Trauma Surgery 12/2011

01-12-2011 | Hip Arthroplasty

Eight-year wear analysis in Longevity highly cross-linked polyethylene liners comparing 26- and 32-mm heads

Authors: Ichiro Nakahara, Nobuo Nakamura, Masaki Takao, Takashi Sakai, Takashi Nishii, Nobuhiko Sugano

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 12/2011

Login to get access

Abstract

Introduction

Although wear reduction of highly cross-linked polyethylene has been demonstrated to be independent of femoral head diameter in some simulation studies, the clinical effects of femoral head diameter on wear of highly cross-linked polyethylene sockets remain unclear. We compared the in vivo wear of Longevity highly cross-linked polyethylene liners at 8-year follow-up using 26- or 32-mm cobalt-chromium heads.

Materials and methods

A retrospective cohort study was performed on 90 cementless total hip arthroplasties (THAs) using Longevity highly cross-linked polyethylene liners combined with 26- (45 THAs) or 32-mm (45 THAs) cobalt-chromium heads. Annual radiographs were analyzed using PolyWare computer-assisted methods and linear and volumetric total head penetration rates and linear and volumetric steady-state wear rates were compared.

Results

The two groups showed similar background data, and no significant differences were identified between groups in total head penetration rate or steady-state wear rate. Steady-state wear rates were negligible. Osteolysis was not observed in any hips in either group.

Conclusions

At the 8-year follow-up, wear of the Longevity was the same irrespective of the use 26- or 32-mm heads.
Literature
1.
go back to reference Harris WH (1995) The problem is osteolysis. Clin Orthop Relat Res 311:46–53PubMed Harris WH (1995) The problem is osteolysis. Clin Orthop Relat Res 311:46–53PubMed
2.
go back to reference Schmalzried TP, Huk OL (2004) Patient factors and wear in total hip arthroplasty. Clin Orthop Relat Res 418:94–97PubMedCrossRef Schmalzried TP, Huk OL (2004) Patient factors and wear in total hip arthroplasty. Clin Orthop Relat Res 418:94–97PubMedCrossRef
3.
go back to reference Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ (1998) Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 13:530–534PubMedCrossRef Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ (1998) Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 13:530–534PubMedCrossRef
4.
go back to reference Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72:518–528PubMed Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72:518–528PubMed
5.
go back to reference Kabo JM, Gebhard JS, Loren G, Amstutz HC (1993) In vivo wear of polyethylene acetabular components. J Bone Joint Surg Br 75:254–258PubMed Kabo JM, Gebhard JS, Loren G, Amstutz HC (1993) In vivo wear of polyethylene acetabular components. J Bone Joint Surg Br 75:254–258PubMed
6.
go back to reference Muratoglu OK, Bragdon CR, O’Connor DO, Jasty M, Harris WH (2001) A novel method of cross-linking UHMWPE to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty 16:149–160PubMedCrossRef Muratoglu OK, Bragdon CR, O’Connor DO, Jasty M, Harris WH (2001) A novel method of cross-linking UHMWPE to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty 16:149–160PubMedCrossRef
7.
go back to reference McKellop H, Shen FW, Lu B, Campbell P, Salovey R (1999) Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 17:157–167PubMedCrossRef McKellop H, Shen FW, Lu B, Campbell P, Salovey R (1999) Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 17:157–167PubMedCrossRef
8.
go back to reference Thomas GE, Simpson DJ, Mehmood S, Taylor A, McLardy-Smith P, Singh Gill H, Murray DW, Glyn-Jones S (2011) The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg Am 93:716–722PubMedCrossRef Thomas GE, Simpson DJ, Mehmood S, Taylor A, McLardy-Smith P, Singh Gill H, Murray DW, Glyn-Jones S (2011) The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg Am 93:716–722PubMedCrossRef
9.
go back to reference Capello WN, D’Antonio JA, Ramakrishnan R, Naughton M (2011) Continued improved wear with an annealed highly cross-linked polyethylene. Clin Orthop Relat Res 469:825–830PubMedCrossRef Capello WN, D’Antonio JA, Ramakrishnan R, Naughton M (2011) Continued improved wear with an annealed highly cross-linked polyethylene. Clin Orthop Relat Res 469:825–830PubMedCrossRef
10.
go back to reference Kadar T, Hallan G, Aamodt A, Indrekyam K, Badawy M, Skredderstuen A, Havelin LI, Stokke T, Haugan K, Espehaug B, Furnes O (2011) Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients. J Orthop Res 29(8):1222–1229. doi:10.1002/jor.21389 PubMedCrossRef Kadar T, Hallan G, Aamodt A, Indrekyam K, Badawy M, Skredderstuen A, Havelin LI, Stokke T, Haugan K, Espehaug B, Furnes O (2011) Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients. J Orthop Res 29(8):1222–1229. doi:10.​1002/​jor.​21389 PubMedCrossRef
11.
go back to reference Muratoglu OK, Bragdon CR, O’Connor D, Perinchief RS, Estok DM 2nd, Jasty M, Harris WH (2001) Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept. J Arthroplasty 16(Suppl 1):24–30PubMedCrossRef Muratoglu OK, Bragdon CR, O’Connor D, Perinchief RS, Estok DM 2nd, Jasty M, Harris WH (2001) Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept. J Arthroplasty 16(Suppl 1):24–30PubMedCrossRef
12.
go back to reference Nakahara I, Nakamura N, Nishii T, Miki H, Sakai T, Sugano N (2010) Minimum five-year follow-up wear measurement of Longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads. J Arthroplasty 25:1182–1187PubMedCrossRef Nakahara I, Nakamura N, Nishii T, Miki H, Sakai T, Sugano N (2010) Minimum five-year follow-up wear measurement of Longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads. J Arthroplasty 25:1182–1187PubMedCrossRef
13.
go back to reference Merle d’Aubigne R, Postel M (1954) Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg 36:451–475 Merle d’Aubigne R, Postel M (1954) Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg 36:451–475
14.
go back to reference Amstutz HC, Thomas BJ, Jinnah R, Kim W, Grogan T, Yale C (1984) Treatment of primary osteoarthritis of the hip: A comparison of total joint and surface replacement arthroplasty. J Bone Joint Surg Am 66:228–241PubMed Amstutz HC, Thomas BJ, Jinnah R, Kim W, Grogan T, Yale C (1984) Treatment of primary osteoarthritis of the hip: A comparison of total joint and surface replacement arthroplasty. J Bone Joint Surg Am 66:228–241PubMed
15.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed
16.
go back to reference Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27PubMed
17.
go back to reference Devane PA, Horne JG (1999) Assessment of polyethylene wear in total hip replacement. Clin Orthop Relat Res 369:59–72PubMedCrossRef Devane PA, Horne JG (1999) Assessment of polyethylene wear in total hip replacement. Clin Orthop Relat Res 369:59–72PubMedCrossRef
18.
go back to reference Bragdon CR, Barrett S, Martell JM, Greene ME, Malchau H, Harris WH (2006) Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up. J Arthroplasty 21:935–943PubMedCrossRef Bragdon CR, Barrett S, Martell JM, Greene ME, Malchau H, Harris WH (2006) Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up. J Arthroplasty 21:935–943PubMedCrossRef
19.
go back to reference Geller JA, Malchau H, Bragdon C, Greene M, Harris WH, Freiberg AA (2006) Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results. Clin Orthop Relat Res 447:53–59PubMedCrossRef Geller JA, Malchau H, Bragdon C, Greene M, Harris WH, Freiberg AA (2006) Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results. Clin Orthop Relat Res 447:53–59PubMedCrossRef
20.
go back to reference Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH (2005) In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 20:880–886PubMedCrossRef Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH (2005) In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 20:880–886PubMedCrossRef
21.
go back to reference Zar JH (1999) Biostatistical analysis, 4th edn edn. Prentice-Hall, New Jersey Zar JH (1999) Biostatistical analysis, 4th edn edn. Prentice-Hall, New Jersey
22.
go back to reference D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW Jr (2000) The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am 82:315–321PubMed D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW Jr (2000) The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am 82:315–321PubMed
23.
go back to reference Bartz RL, Nobel PC, Kadakia NR, Tullos HS (2000) The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82:1300–1307PubMed Bartz RL, Nobel PC, Kadakia NR, Tullos HS (2000) The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82:1300–1307PubMed
24.
go back to reference Dowd JE, Sychterz CJ, Young AM, Engh CA (2000) Characterization of long-term femoral-head-penetration rates: association with and prediction of osteolysis. J Bone Joint Surg 82:1102–1107PubMed Dowd JE, Sychterz CJ, Young AM, Engh CA (2000) Characterization of long-term femoral-head-penetration rates: association with and prediction of osteolysis. J Bone Joint Surg 82:1102–1107PubMed
25.
go back to reference Bragdon CR, Kwon YM, Geller JA, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Minimum 6-year followup of highly cross-linked polyethylene in THA. Clin Orthop Relat Res 465:122–127PubMed Bragdon CR, Kwon YM, Geller JA, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Minimum 6-year followup of highly cross-linked polyethylene in THA. Clin Orthop Relat Res 465:122–127PubMed
26.
go back to reference Lachiewicz PF, Heckman DS, Soileau ES, Mangla J, Martell JM (2009) Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years. Clin Orthop Relat Res 467:3290–3296PubMedCrossRef Lachiewicz PF, Heckman DS, Soileau ES, Mangla J, Martell JM (2009) Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years. Clin Orthop Relat Res 467:3290–3296PubMedCrossRef
27.
go back to reference Digas G, Kärrholm J, Thanner J, Herberts P (2007) 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis. Acta Orthop 78:746–754PubMedCrossRef Digas G, Kärrholm J, Thanner J, Herberts P (2007) 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis. Acta Orthop 78:746–754PubMedCrossRef
28.
go back to reference Röhrl SM, Li MG, Nilsson KG, Nivbrant B (2007) Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years. Acta Orthop 78:739–745PubMedCrossRef Röhrl SM, Li MG, Nilsson KG, Nivbrant B (2007) Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years. Acta Orthop 78:739–745PubMedCrossRef
29.
go back to reference Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs. 28-mm femoral heads. J Arthroplasty 22(suppl 2):125–129PubMedCrossRef Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs. 28-mm femoral heads. J Arthroplasty 22(suppl 2):125–129PubMedCrossRef
30.
go back to reference Hammerberg EM, Wan Z, Dastane M, Dorr LD (2010) Wear and range of motion of different femoral head sizes. J Arthroplastyty 25:839–843CrossRef Hammerberg EM, Wan Z, Dastane M, Dorr LD (2010) Wear and range of motion of different femoral head sizes. J Arthroplastyty 25:839–843CrossRef
31.
go back to reference Bartel DL, Wright TM, Edwards D (1983) The effect of metal backing on stresses in polyethylene acetabular components. Hip 229–39 Bartel DL, Wright TM, Edwards D (1983) The effect of metal backing on stresses in polyethylene acetabular components. Hip 229–39
32.
go back to reference Kurtz SM, Villarraga ML, Herr MP, Bergström JS, Rimnac CM, Edidin AA (2002) Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements. Biomaterials 23:3681–3697PubMedCrossRef Kurtz SM, Villarraga ML, Herr MP, Bergström JS, Rimnac CM, Edidin AA (2002) Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements. Biomaterials 23:3681–3697PubMedCrossRef
33.
go back to reference Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB (2007) Rim cracking of the cross-linked Longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 89:2212–2217PubMedCrossRef Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB (2007) Rim cracking of the cross-linked Longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 89:2212–2217PubMedCrossRef
34.
go back to reference Moore KD, Barrack RL, Sychterz CJ, Sawhney J, Yang AM, Engh CA (2000) The effect of weight-bearing on the radiographic measurement of the position of the femoral head after total hip arthroplasty. J Bone Joint Surg Am 82:62–69PubMedCrossRef Moore KD, Barrack RL, Sychterz CJ, Sawhney J, Yang AM, Engh CA (2000) The effect of weight-bearing on the radiographic measurement of the position of the femoral head after total hip arthroplasty. J Bone Joint Surg Am 82:62–69PubMedCrossRef
Metadata
Title
Eight-year wear analysis in Longevity highly cross-linked polyethylene liners comparing 26- and 32-mm heads
Authors
Ichiro Nakahara
Nobuo Nakamura
Masaki Takao
Takashi Sakai
Takashi Nishii
Nobuhiko Sugano
Publication date
01-12-2011
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 12/2011
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1360-z

Other articles of this Issue 12/2011

Archives of Orthopaedic and Trauma Surgery 12/2011 Go to the issue