Abstract

Purpose

In line with several designs for osteosynthesis of femoral neck fracture (FNF), their effectiveness is still estimated by the results of biomechanical and clinical trials, finite element method (FE). But surgeons require the criteria which would define their properties in advance and allow improve the results of treatment.

Methods

When new implant (NI) is being designed, we developed such criterion – index efficiency of an implant (IEI) – and performed mathematical comparative researches of properties of NI with the known designs. We analyzed the results of comparative clinical trials on treatment of FNF with various implants considering their IEI.

Results

Analysis showed that results of comparative clinical trials with the use of various implants for osteosynthesis FNF completely correlated to their IEI; IEI of the NI two to three times exceeds IEI of all known designs, and the destruction percentage of a bone tissue is two to three times less when it is applied.

Conclusion

The offered IEI can be used for designing new implants and allows improving the results of treatment of patients with FNF by optimizing the choice of implant for osteosynthesis.
Literature
2.
go back to reference The FAITH Investigatiors (2014) Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures. BMC Musculoskelet Disord 15:219. https://doi.org/10.1186/1471-2474-15-219 CrossRef The FAITH Investigatiors (2014) Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures. BMC Musculoskelet Disord 15:219. https://​doi.​org/​10.​1186/​1471-2474-15-219 CrossRef
4.
go back to reference Chua D, Jagai SB, Schatzker J (1997) An orthopedic surgeon survey on the treatment of displaced femoral neck fracture: opposing views. Can J Surg 40:271–277PubMedPubMedCentral Chua D, Jagai SB, Schatzker J (1997) An orthopedic surgeon survey on the treatment of displaced femoral neck fracture: opposing views. Can J Surg 40:271–277PubMedPubMedCentral
6.
go back to reference Bhandari M, Devereaux PJ, Swiontkowski M, Tornetta P, Obremskey W, Koval K, Nork S, Sprague S, Schemitsch E, Guyatt G (2003) Internal fixation compared with arthroplasty for displaced fractures of the femoral neck. J Bone Joint Surg 85A:1673–1681CrossRef Bhandari M, Devereaux PJ, Swiontkowski M, Tornetta P, Obremskey W, Koval K, Nork S, Sprague S, Schemitsch E, Guyatt G (2003) Internal fixation compared with arthroplasty for displaced fractures of the femoral neck. J Bone Joint Surg 85A:1673–1681CrossRef
7.
go back to reference Elmerson S, Sjostedt A, Zetterberg C (1995) Fixation of femoral neck fracture. A randomized 2-year follow-up study of hook pins and sliding screw plate in 222 patients. Acta Orthop Scand 66:507–510CrossRef Elmerson S, Sjostedt A, Zetterberg C (1995) Fixation of femoral neck fracture. A randomized 2-year follow-up study of hook pins and sliding screw plate in 222 patients. Acta Orthop Scand 66:507–510CrossRef
11.
go back to reference Radchenko VP, Nekhozhin AV, Matveev AL (2011) Mathematical modeling of the stressed state of the reinforced bone tissue of the femoral neck with static loads. Vestn.Sam.gos.tehn.un-ta.Ser.Fiz.-mat. Science 4(25):75–81 Radchenko VP, Nekhozhin AV, Matveev AL (2011) Mathematical modeling of the stressed state of the reinforced bone tissue of the femoral neck with static loads. Vestn.Sam.gos.tehn.un-ta.Ser.Fiz.-mat. Science 4(25):75–81
12.
go back to reference Strömqvist B, Hansson LI (1984) Femoral head vitality in femoral neck fracture after hook-pin internal fixation. Clin Orthop Relat Res 191:105–109 Strömqvist B, Hansson LI (1984) Femoral head vitality in femoral neck fracture after hook-pin internal fixation. Clin Orthop Relat Res 191:105–109
13.
go back to reference Strömqvist B, Hansson LI (1983) Avascular necrosis associated with nailing of femoral neck fracture. Two cases examined pre- and postoperatively by tetracycline and radionuclide tracer techniques. Acta Orthop Scand 54(5):687–694CrossRef Strömqvist B, Hansson LI (1983) Avascular necrosis associated with nailing of femoral neck fracture. Two cases examined pre- and postoperatively by tetracycline and radionuclide tracer techniques. Acta Orthop Scand 54(5):687–694CrossRef
14.
go back to reference Strömqvist B, Hansson LI, Palmer J, Ceder L, Thorngren KG (1983) Scintimetric evaluation of nailed femoral neck fractures with special reference to type of osteosynthesis. Acta Orthop Scand 54(3):340–347CrossRef Strömqvist B, Hansson LI, Palmer J, Ceder L, Thorngren KG (1983) Scintimetric evaluation of nailed femoral neck fractures with special reference to type of osteosynthesis. Acta Orthop Scand 54(3):340–347CrossRef
16.
go back to reference Alfredo Brodetti I (1960) Blood supply of the femoral neck and head in relation to the damaging effects of nails and screws. The Journal of Bone and Joint Surgery 42 b(4):794–801CrossRef Alfredo Brodetti I (1960) Blood supply of the femoral neck and head in relation to the damaging effects of nails and screws. The Journal of Bone and Joint Surgery 42 b(4):794–801CrossRef
19.
go back to reference Chen Z, Wang G, Lin J, Yang T, Fang Y, Liu L, Zhang H (2011) Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 25(1):26–29PubMed Chen Z, Wang G, Lin J, Yang T, Fang Y, Liu L, Zhang H (2011) Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 25(1):26–29PubMed
22.
go back to reference Hou WR, Xu MO (2015) Comparison among three cannulated screws and dynamic hip screw combined with antirotation screw for comminuted fractures of femoral neck. Zhongguo Gu Shang 28(9):796–801PubMed Hou WR, Xu MO (2015) Comparison among three cannulated screws and dynamic hip screw combined with antirotation screw for comminuted fractures of femoral neck. Zhongguo Gu Shang 28(9):796–801PubMed
26.
go back to reference Zhang LL, Zhang Y, Ma X, Liu Y (2017) Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures a meta-analysis. Der Orthopade 46(11):954–962CrossRef Zhang LL, Zhang Y, Ma X, Liu Y (2017) Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures a meta-analysis. Der Orthopade 46(11):954–962CrossRef
28.
go back to reference Levi N (1999) Dynamic hip screw versus 3 parallel screws in the treatment of garden 1 + 2 and garden 3 + 4 cervical hip fractures. Panminerva Med Sep 41(3):233–237 Levi N (1999) Dynamic hip screw versus 3 parallel screws in the treatment of garden 1 + 2 and garden 3 + 4 cervical hip fractures. Panminerva Med Sep 41(3):233–237
30.
go back to reference Linke B, Schwieger K, Bursic D, Dutoit C, Ulrich D, Gautier E (2004) Treatment of unstable femoral neck fractures: is the dynamic hip screw a superior alternative to 3 cannulated screws? Poster session presented at: OTA Annual Meeting (Poster 55): 8–10 October 2004. Hollywood: Orthopaedic Trauma Association Linke B, Schwieger K, Bursic D, Dutoit C, Ulrich D, Gautier E (2004) Treatment of unstable femoral neck fractures: is the dynamic hip screw a superior alternative to 3 cannulated screws? Poster session presented at: OTA Annual Meeting (Poster 55): 8–10 October 2004. Hollywood: Orthopaedic Trauma Association
33.
go back to reference Ananiev NI, Boykov VP, Merkulova LM, Stolyarov SI, Romanova LP (2003) Some topographic-anatomical and biomechanical features of the structure of the proximal epiphysis of the human femur. Journal of Successes of Modern Science 10:50–51 Ananiev NI, Boykov VP, Merkulova LM, Stolyarov SI, Romanova LP (2003) Some topographic-anatomical and biomechanical features of the structure of the proximal epiphysis of the human femur. Journal of Successes of Modern Science 10:50–51
34.
go back to reference Hoshino MC, O’Toole RV (2014) Fixed angle devices versus multiple cancellous screws: what does the evidence tell us? Injury 46(3):474–477CrossRef Hoshino MC, O’Toole RV (2014) Fixed angle devices versus multiple cancellous screws: what does the evidence tell us? Injury 46(3):474–477CrossRef
Metadata
Title
Efficiency of an implant: new criterion of objective assessment of implants for osteosynthesis of femoral neck fracture
Authors
Chingiz Alizade
Afgan Jafarov
Farhad Alizada
Mahir Gülsen
Emre Togrul
Publication date
01-03-2020
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 3/2020
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-019-04439-2

Other articles of this Issue 3/2020

International Orthopaedics 3/2020 Go to the issue