Skip to main content
Top
Published in: Journal of Digital Imaging 5/2018

01-10-2018

Efficiency Improvement in a Busy Radiology Practice: Determination of Musculoskeletal Magnetic Resonance Imaging Protocol Using Deep-Learning Convolutional Neural Networks

Author: Young Han Lee

Published in: Journal of Imaging Informatics in Medicine | Issue 5/2018

Login to get access

Abstract

The purposes of this study are to evaluate the feasibility of protocol determination with a convolutional neural networks (CNN) classifier based on short-text classification and to evaluate the agreements by comparing protocols determined by CNN with those determined by musculoskeletal radiologists. Following institutional review board approval, the database of a hospital information system (HIS) was queried for lists of MRI examinations, referring department, patient age, and patient gender. These were exported to a local workstation for analyses: 5258 and 1018 consecutive musculoskeletal MRI examinations were used for the training and test datasets, respectively. The subjects for pre-processing were routine or tumor protocols and the contents were word combinations of the referring department, region, contrast media (or not), gender, and age. The CNN Embedded vector classifier was used with Word2Vec Google news vectors. The test set was tested with each classification model and results were output as routine or tumor protocols. The CNN determinations were evaluated using the receiver operating characteristic (ROC) curves. The accuracies were evaluated by a radiologist-confirmed protocol as the reference protocols. The optimal cut-off values for protocol determination between routine protocols and tumor protocols was 0.5067 with a sensitivity of 92.10%, a specificity of 95.76%, and an area under curve (AUC) of 0.977. The overall accuracy was 94.2% for the ConvNet model. All MRI protocols were correct in the pelvic bone, upper arm, wrist, and lower leg MRIs. Deep-learning-based convolutional neural networks were clinically utilized to determine musculoskeletal MRI protocols. CNN-based text learning and applications could be extended to other radiologic tasks besides image interpretations, improving the work performance of the radiologist.
Literature
2.
go back to reference Edelstein WA, Mahesh M, Carrino JA: MRI: time is dose—and money and versatility. J Am Coll Radiol 7:650–652, 2010CrossRef Edelstein WA, Mahesh M, Carrino JA: MRI: time is dose—and money and versatility. J Am Coll Radiol 7:650–652, 2010CrossRef
3.
go back to reference Mekle R, Wu EX, Meckel S, Wetzel SG, Scheffler K: Combo acquisitions: balancing scan time reduction and image quality. Magn Reson Med 55:1093–1105, 2006CrossRef Mekle R, Wu EX, Meckel S, Wetzel SG, Scheffler K: Combo acquisitions: balancing scan time reduction and image quality. Magn Reson Med 55:1093–1105, 2006CrossRef
4.
5.
go back to reference Ayaru L, Ypsilantis PP, Nanapragasam A, Choi RCH, Thillanathan A, Min-Ho L, Montana G: Prediction of outcome in acute lower gastrointestinal bleeding using gradient boosting. PLoS One 10:e0132485, 2015CrossRef Ayaru L, Ypsilantis PP, Nanapragasam A, Choi RCH, Thillanathan A, Min-Ho L, Montana G: Prediction of outcome in acute lower gastrointestinal bleeding using gradient boosting. PLoS One 10:e0132485, 2015CrossRef
6.
go back to reference Ogutu JO, Schulz-Streeck T, Piepho HP: Genomic selection using regularized linear regression models: ridge regression, lasso, elastic net and their extensions. BMC Proc 6(Suppl 2):S10, 2012CrossRef Ogutu JO, Schulz-Streeck T, Piepho HP: Genomic selection using regularized linear regression models: ridge regression, lasso, elastic net and their extensions. BMC Proc 6(Suppl 2):S10, 2012CrossRef
7.
go back to reference Forsberg D, Sjoblom E, Sunshine JL: Detection and labeling of vertebrae in MR images using deep learning with clinical annotations as training data. J Digit Imaging 30:406–412, 2017CrossRef Forsberg D, Sjoblom E, Sunshine JL: Detection and labeling of vertebrae in MR images using deep learning with clinical annotations as training data. J Digit Imaging 30:406–412, 2017CrossRef
9.
go back to reference Kim Y: Convolutional neural networks for sentence classification. ArXiv e-prints abs/1408.5882, 2014 Kim Y: Convolutional neural networks for sentence classification. ArXiv e-prints abs/1408.5882, 2014
10.
go back to reference Thrall JH, Li X, Li Q, Cruz C, Do S, Dreyer K, Brink J: Artificial intelligence and machine learning in radiology: opportunities, challenges, pitfalls, and criteria for success. J Am Coll Radiol 15:504–508, 2018CrossRef Thrall JH, Li X, Li Q, Cruz C, Do S, Dreyer K, Brink J: Artificial intelligence and machine learning in radiology: opportunities, challenges, pitfalls, and criteria for success. J Am Coll Radiol 15:504–508, 2018CrossRef
12.
go back to reference Pereira S, Pinto A, Alves V, Silva CA: Brain tumor segmentation using convolutional neural networks in MRI images. IEEE Trans Med Imaging 35:1240–1251, 2016CrossRef Pereira S, Pinto A, Alves V, Silva CA: Brain tumor segmentation using convolutional neural networks in MRI images. IEEE Trans Med Imaging 35:1240–1251, 2016CrossRef
13.
go back to reference Setio AAA, Ciompi F, Litjens G, Gerke P, Jacobs C, van Riel SJ, Wille MMW, Naqibullah M, Sanchez CI, van Ginneken B: Pulmonary nodule detection in CT images: false positive reduction using multi-view convolutional networks. IEEE Trans Med Imaging 35:1160–1169, 2016CrossRef Setio AAA, Ciompi F, Litjens G, Gerke P, Jacobs C, van Riel SJ, Wille MMW, Naqibullah M, Sanchez CI, van Ginneken B: Pulmonary nodule detection in CT images: false positive reduction using multi-view convolutional networks. IEEE Trans Med Imaging 35:1160–1169, 2016CrossRef
14.
go back to reference Sangwaiya MJ, Saini S, Blake MA, Dreyer KJ, Kalra MK: Errare humanum est: frequency of laterality errors in radiology reports. AJR Am J Roentgenol 192:W239–W244, 2009CrossRef Sangwaiya MJ, Saini S, Blake MA, Dreyer KJ, Kalra MK: Errare humanum est: frequency of laterality errors in radiology reports. AJR Am J Roentgenol 192:W239–W244, 2009CrossRef
15.
go back to reference Luetmer MT, Hunt CH, McDonald RJ, Bartholmai BJ, Kallmes DF: Laterality errors in radiology reports generated with and without voice recognition software: frequency and clinical significance. J Am Coll Radiol 10:538–543, 2013CrossRef Luetmer MT, Hunt CH, McDonald RJ, Bartholmai BJ, Kallmes DF: Laterality errors in radiology reports generated with and without voice recognition software: frequency and clinical significance. J Am Coll Radiol 10:538–543, 2013CrossRef
16.
go back to reference Lee YH, Yang J, Suh JS: Detection and correction of laterality errors in radiology reports. J Digit Imaging 28:412–416, 2015CrossRef Lee YH, Yang J, Suh JS: Detection and correction of laterality errors in radiology reports. J Digit Imaging 28:412–416, 2015CrossRef
18.
go back to reference Gyftopoulos S, Kim D, Aaltonen E, Horwitz LI: Patient recall imaging in the ambulatory setting. Am J Roentgenol 206:787–791, 2016CrossRef Gyftopoulos S, Kim D, Aaltonen E, Horwitz LI: Patient recall imaging in the ambulatory setting. Am J Roentgenol 206:787–791, 2016CrossRef
Metadata
Title
Efficiency Improvement in a Busy Radiology Practice: Determination of Musculoskeletal Magnetic Resonance Imaging Protocol Using Deep-Learning Convolutional Neural Networks
Author
Young Han Lee
Publication date
01-10-2018
Publisher
Springer International Publishing
Published in
Journal of Imaging Informatics in Medicine / Issue 5/2018
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-018-0066-y

Other articles of this Issue 5/2018

Journal of Digital Imaging 5/2018 Go to the issue