Skip to main content
Top
Published in: Odontology 2/2019

01-04-2019 | Original Article

Effects of etidronate, NaOCl, EDTA irrigation solutions and their combinations on cyclic fatigue resistance of nickel–titanium single-file rotary and reciprocating instruments at body temperature

Authors: Cevat Emre Erik, Taha Özyürek

Published in: Odontology | Issue 2/2019

Login to get access

Abstract

The aim of the present study was to compare the effect of etidronic acid (HEBP), NaOCl, and EDTA solutions and their combinations on cyclic fatigue resistance of NiTi RPC Blue (RPC Blue), HyFlex EDM (HEDM), and WaveOne Gold (WOG) instruments having different metallurgic characteristics at the body temperature (37 °C). 100 WOG, 100 RPC Blue, and 100 HEDM NiTi files were randomly divided into 5 groups and immersed in the following solutions: group 1, distilled water; group 2, 6% NaOCl; group 3, 17% EDTA; group 4, 18% HEBP; group 5, 6% NaOCl and 18% HEBP. Then the instruments were rotated in an artificial canal until fracture occurred and the number of cycles to fracture was calculated. A univariate analysis of variance and post hoc Tukey tests were then performed for comparisons using SPSS 21.0 software with the significance level set at P < .05. In all the conditions, there was no difference between the cyclic fatigue resistance of WOG and RPC Blue files (P > .05). In the intragroup comparison, WOG, RPC Blue, and HEDM files showed significantly low cyclic fatigue resistance in group 5 compared to other groups (P < .05). Among the groups, there was no statistically significant difference in the fracture lengths (P > .05). EDTA, NaOCl and HEBP solutions did not affect the cyclic fatigue resistance of the tested files when used without combination. However, the combination of NaOCl and HEBP solutions significantly reduced the cyclic fatigue resistance of the tested files.
Literature
1.
go back to reference Schäfer E, Erler M, Dammaschke T. Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals. Int Endod J. 2006;39:196–02.CrossRefPubMed Schäfer E, Erler M, Dammaschke T. Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals. Int Endod J. 2006;39:196–02.CrossRefPubMed
4.
go back to reference Gündoğar M, Özyürek T. Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue nickel–titanium instruments. J Endod. 2017;43:1192–6.CrossRef Gündoğar M, Özyürek T. Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue nickel–titanium instruments. J Endod. 2017;43:1192–6.CrossRef
5.
go back to reference Pirani C, Iacono F, Generali L, et al. HyFlex EDM: superficial features, metallurgical analysis and fatigue resistance of innovative electro discharge machined NiTi rotary instruments. Int Endod J. 2016;49:483–93.CrossRefPubMed Pirani C, Iacono F, Generali L, et al. HyFlex EDM: superficial features, metallurgical analysis and fatigue resistance of innovative electro discharge machined NiTi rotary instruments. Int Endod J. 2016;49:483–93.CrossRefPubMed
6.
go back to reference Pedullà E, Savio FL, Boninelli S, et al. Torsional and cyclic fatigue resistance of a new nickel–titanium instrument manufactured by electrical discharge machining. J Endod. 2016;42:156–9.CrossRef Pedullà E, Savio FL, Boninelli S, et al. Torsional and cyclic fatigue resistance of a new nickel–titanium instrument manufactured by electrical discharge machining. J Endod. 2016;42:156–9.CrossRef
7.
go back to reference Byström A, Sundqvist G. Bacteriologic evaluation of the effect of 0.5 percent sodium hypochlorite in endodontic therapy. Oral Surg Oral Med Oral Pathol Oral. 1983;55:307–12.CrossRef Byström A, Sundqvist G. Bacteriologic evaluation of the effect of 0.5 percent sodium hypochlorite in endodontic therapy. Oral Surg Oral Med Oral Pathol Oral. 1983;55:307–12.CrossRef
9.
go back to reference Bonaccorso A, Tripi TR, Rondelli G, Condorelli GG, Cantatore G, Schäfer E. Pitting corrosion resistance of nickel–titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic acid and sodium chloride solutions. J Endod. 2008;34:208–11.CrossRefPubMed Bonaccorso A, Tripi TR, Rondelli G, Condorelli GG, Cantatore G, Schäfer E. Pitting corrosion resistance of nickel–titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic acid and sodium chloride solutions. J Endod. 2008;34:208–11.CrossRefPubMed
10.
go back to reference Sarkar N, Redmond W, Schwaninger B, Goldberg A. The chloride corrosion behaviour of four orthodontic wires. J Oral Rehabil. 1983;10:121–8.CrossRefPubMed Sarkar N, Redmond W, Schwaninger B, Goldberg A. The chloride corrosion behaviour of four orthodontic wires. J Oral Rehabil. 1983;10:121–8.CrossRefPubMed
11.
go back to reference Darabara M, Bourithis L, Zinelis S, Papadimitriou G. Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions. Int Endod J. 2004;37:705–10.CrossRefPubMed Darabara M, Bourithis L, Zinelis S, Papadimitriou G. Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions. Int Endod J. 2004;37:705–10.CrossRefPubMed
12.
go back to reference Berutti E, Angelini E, Rigolone M, Migliaretti G, Pasqualini D. Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments. Int Endod J. 2006;39:693–9.CrossRefPubMed Berutti E, Angelini E, Rigolone M, Migliaretti G, Pasqualini D. Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments. Int Endod J. 2006;39:693–9.CrossRefPubMed
13.
go back to reference Cheung GS, Darvell BW. Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution. Dent Mater. 2008;24:753–9.CrossRefPubMed Cheung GS, Darvell BW. Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution. Dent Mater. 2008;24:753–9.CrossRefPubMed
14.
go back to reference Zehnder M, Schmidlin P, Sener B, Waltimo T. Chelation in root canal therapy reconsidered. J Endod. 2005;31:817–20.CrossRefPubMed Zehnder M, Schmidlin P, Sener B, Waltimo T. Chelation in root canal therapy reconsidered. J Endod. 2005;31:817–20.CrossRefPubMed
15.
go back to reference Tartari T, Guimarães B, Amoras L, Duarte M, Silva e Souza P, Bramante C. Etidronate causes minimal changes in the ability of sodium hypochlorite to dissolve organic matter. Int Endod J. 2015;48:399–404.CrossRefPubMed Tartari T, Guimarães B, Amoras L, Duarte M, Silva e Souza P, Bramante C. Etidronate causes minimal changes in the ability of sodium hypochlorite to dissolve organic matter. Int Endod J. 2015;48:399–404.CrossRefPubMed
16.
go back to reference Lottanti S, Gautschi H, Sener B, Zehnder M. Effects of ethylenediaminetetraacetic, etidronic and peracetic acid irrigation on human root dentine and the smear layer. Int Endod J. 2009;42:335–43.CrossRefPubMed Lottanti S, Gautschi H, Sener B, Zehnder M. Effects of ethylenediaminetetraacetic, etidronic and peracetic acid irrigation on human root dentine and the smear layer. Int Endod J. 2009;42:335–43.CrossRefPubMed
17.
go back to reference Huang X, Shen Y, Wei X, Haapasalo M. Fatigue resistance of nickel–titanium instruments exposed to high-concentration hypochlorite. J Endod 2017;43:1847–51.CrossRefPubMed Huang X, Shen Y, Wei X, Haapasalo M. Fatigue resistance of nickel–titanium instruments exposed to high-concentration hypochlorite. J Endod 2017;43:1847–51.CrossRefPubMed
18.
go back to reference Higuera O, Plotino G, Tocci L, Carrillo G, Gambarini G, Jaramillo DE. Cyclic fatigue resistance of 3 different nickel–titanium reciprocating instruments in artificial canals. J Endod. 2015;41:913–5.CrossRefPubMed Higuera O, Plotino G, Tocci L, Carrillo G, Gambarini G, Jaramillo DE. Cyclic fatigue resistance of 3 different nickel–titanium reciprocating instruments in artificial canals. J Endod. 2015;41:913–5.CrossRefPubMed
19.
go back to reference Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne Gold nickel–titanium instruments. J Endod. 2016;42:1536–9.CrossRef Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne Gold nickel–titanium instruments. J Endod. 2016;42:1536–9.CrossRef
20.
go back to reference Grawehr M, Sener B, Waltimo T, Zehnder M. Interactions of ethylenediamine tetraacetic acid with sodium hypochlorite in aqueous solutions. Int Endod J. 2003;36:411–5.CrossRefPubMed Grawehr M, Sener B, Waltimo T, Zehnder M. Interactions of ethylenediamine tetraacetic acid with sodium hypochlorite in aqueous solutions. Int Endod J. 2003;36:411–5.CrossRefPubMed
21.
go back to reference Ametrano G, D’Ant V, Di Caprio M, et al. Effects of sodium hypochlorite and ethylenediaminetetraacetic acid on rotary nickel–titanium instruments evaluated using atomic force microscopy. Int Endod J. 2011;44:203–9.CrossRefPubMed Ametrano G, D’Ant V, Di Caprio M, et al. Effects of sodium hypochlorite and ethylenediaminetetraacetic acid on rotary nickel–titanium instruments evaluated using atomic force microscopy. Int Endod J. 2011;44:203–9.CrossRefPubMed
22.
go back to reference Topuz O, Aydin C, Uzun O, et al. Structural effects of sodium hypochlorite solution on RaCe rotary nickel–titanium instruments: an atomic force microscopy study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;105:661–5.CrossRefPubMed Topuz O, Aydin C, Uzun O, et al. Structural effects of sodium hypochlorite solution on RaCe rotary nickel–titanium instruments: an atomic force microscopy study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;105:661–5.CrossRefPubMed
23.
go back to reference Plotino G, Grande NM, Cordaro M, et al. Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009;108:e152–6.CrossRefPubMed Plotino G, Grande NM, Cordaro M, et al. Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009;108:e152–6.CrossRefPubMed
24.
go back to reference de Vasconcelos RA, Murphy S, Carvalho CAT, Govindjee RG, Govindjee S, Peters OA. Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature. J Endod. 2016;42:782–7.CrossRef de Vasconcelos RA, Murphy S, Carvalho CAT, Govindjee RG, Govindjee S, Peters OA. Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature. J Endod. 2016;42:782–7.CrossRef
25.
go back to reference Plotino G, Grande NM, Bellido MM, Testarelli L, Gambarini G. Influence of temperature on cyclic fatigue resistance of ProTaper Gold and ProTaper Universal rotary files. J Endod. 2017;43:200–2.CrossRef Plotino G, Grande NM, Bellido MM, Testarelli L, Gambarini G. Influence of temperature on cyclic fatigue resistance of ProTaper Gold and ProTaper Universal rotary files. J Endod. 2017;43:200–2.CrossRef
26.
go back to reference Dosanjh A, Paurazas S, Askar M. The effect of temperature on cyclic fatigue of nickel–titanium rotary endodontic instruments. J Endod. 2017;43:823–6.CrossRef Dosanjh A, Paurazas S, Askar M. The effect of temperature on cyclic fatigue of nickel–titanium rotary endodontic instruments. J Endod. 2017;43:823–6.CrossRef
27.
go back to reference Grande NM, Plotino G, Silla E, et al. Environmental temperature drastically affects flexural fatigue resistance of nickel–titanium rotary files. J Endod. 2017;43:1157–60.CrossRefPubMed Grande NM, Plotino G, Silla E, et al. Environmental temperature drastically affects flexural fatigue resistance of nickel–titanium rotary files. J Endod. 2017;43:1157–60.CrossRefPubMed
28.
go back to reference De-Deus G, Moreira E, Lopes H, Elias C. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J. 2010;43:1063–8.CrossRef De-Deus G, Moreira E, Lopes H, Elias C. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J. 2010;43:1063–8.CrossRef
29.
go back to reference Varela-Patiño P, Ibañez-Párraga A, Rivas-Mundiña B, Cantatore G, Otero XL, Martin-Biedma B. Alternating versus continuous rotation: a comparative study of the effect on instrument life. J Endod. 2010;36:157–9.CrossRefPubMed Varela-Patiño P, Ibañez-Párraga A, Rivas-Mundiña B, Cantatore G, Otero XL, Martin-Biedma B. Alternating versus continuous rotation: a comparative study of the effect on instrument life. J Endod. 2010;36:157–9.CrossRefPubMed
30.
go back to reference Elnaghy A, Elsaka S. Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments. Int Endod J. 2017;50:991–8.CrossRef Elnaghy A, Elsaka S. Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments. Int Endod J. 2017;50:991–8.CrossRef
31.
go back to reference Uslu G, Özyürek T, Yılmaz K, Plotino G. Effect of dynamic immersion in sodium hypochlorite and EDTA solutions on cyclic fatigue resistance of WaveOne and WaveOne Gold reciprocating nickel–titanium files. J Endod. 2018;44:843–7. Uslu G, Özyürek T, Yılmaz K, Plotino G. Effect of dynamic immersion in sodium hypochlorite and EDTA solutions on cyclic fatigue resistance of WaveOne and WaveOne Gold reciprocating nickel–titanium files. J Endod. 2018;44:843–7.
32.
go back to reference Pedullà E, Grande N, Plotino G, Palermo F, Gambarini G, Rapisarda E. Cyclic fatigue resistance of two reciprocating nickel–titanium instruments after immersion in sodium hypochlorite. Int Endod J. 2013;46:155–9.CrossRefPubMed Pedullà E, Grande N, Plotino G, Palermo F, Gambarini G, Rapisarda E. Cyclic fatigue resistance of two reciprocating nickel–titanium instruments after immersion in sodium hypochlorite. Int Endod J. 2013;46:155–9.CrossRefPubMed
33.
go back to reference Reinhard G, Radtke M, Rammelt U. On the role of the salts of weak acids in the chemical passivation of iron and steel in aqueous solutions. Corros Sci. 1992;33:307–13.CrossRef Reinhard G, Radtke M, Rammelt U. On the role of the salts of weak acids in the chemical passivation of iron and steel in aqueous solutions. Corros Sci. 1992;33:307–13.CrossRef
34.
go back to reference Cai JJ, Tang XN, Ge JY. Effect of irrigation on surface roughness and fatigue resistance of controlled memory wire nickel–titanium instruments. Int Endod J. 2017;50:718–24.CrossRefPubMed Cai JJ, Tang XN, Ge JY. Effect of irrigation on surface roughness and fatigue resistance of controlled memory wire nickel–titanium instruments. Int Endod J. 2017;50:718–24.CrossRefPubMed
35.
go back to reference Plotino G, Grande NM, Cordaro M, et al. A review on cyclic fatigue testing of nickel–titanium rotary instruments. J Endod. 2009;35:1469–76.CrossRef Plotino G, Grande NM, Cordaro M, et al. A review on cyclic fatigue testing of nickel–titanium rotary instruments. J Endod. 2009;35:1469–76.CrossRef
Metadata
Title
Effects of etidronate, NaOCl, EDTA irrigation solutions and their combinations on cyclic fatigue resistance of nickel–titanium single-file rotary and reciprocating instruments at body temperature
Authors
Cevat Emre Erik
Taha Özyürek
Publication date
01-04-2019
Publisher
Springer Japan
Published in
Odontology / Issue 2/2019
Print ISSN: 1618-1247
Electronic ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-018-0388-8

Other articles of this Issue 2/2019

Odontology 2/2019 Go to the issue